T200 Series Erie™ Digital, On/Off Thermostat T200 Serie T200 series thermostats provide temperature control on a variety of heating, cooling and single stage heat pump applications. The large LCD window displays room temperature including 1/5th of a degree increments indicated by a series of up to 5 dashes. The system heat output cycles on a 1 or 2F degree field selectable differential. The cool output differential is fixed at 2F degrees. The setpoint is displayed and changed by pressing one of the setpoint buttons up or down. Installation is simplified by having all of the field wires mounted to the separate wall plate. Features: • LCD window display, qF standard, qC configurable. • Jumper selectable 5 minute time delay for heating and cooling application. • Mechanical contact for low limit protection (optional). • Base adaptor plate standard. Model Chart Control Outputs Fan Controla System Switcha Changeover Mechanical Contact B & O Terminals T201 Heating Only None Heat/Off None No No T201-FPb Heating Only None Heat/Off None Yes No T204 Cooling Only On/Auto Cool/Off None No No T205 Cooling & Heating On/Auto Cool/Off/Heat Manual No No T205-FPb Cooling & Heating On/Auto Cool/Off/Heat Manual Yes No T207 Cooling & Heating On/Auto Cool/Off/Heat Manual No Yes T207-FPb Cooling & Heating On/Auto Cool/Off/Heat Manual Yes Yes Model No. a Fan switch operates independent of system switch unless relays are added. b Low limit protection, at 40qF the thermostat mechanically latches heat with output. 220 T200 Series Specifications Inputs 20 to 32 Vac, 75 mA to 1.2 amps (power-stealing thermostat, 75 mA required at all times. 250:, 5 watt resistor may be needed). Power input Outputs Electrical Battery: Setpoint backup Energizer 357 or similar (battery included). 1.2 A inductive load max. Setpoint range: 50 to 86qF (10 to 35qC). Control ranges Operating differential: Heating 1 or 2 F degrees field selectable, (0.6 or 1.1 C degrees), Cooling 2 F degrees (1.1 C degrees). Material: Rigid vinyl. Mechanical Finish: Off-white. Environment Ambient temperature limits Shipping and storage: -4 to 125qF (-20 to 52qC). Operating: 40 to 125qF (5 to 53qC). Humidity 95% non-condensing. Locations NEMA Type 1. Dimensions Thermostat:4 H x 2-1/2 W inches (102 x 64 mm). Thermostat base and adaptor plate: 4-3/4 H x 4-1/4 W inches (121 x 108 mm). Agency Listing None. General Instructions Refer to F-27027. Typical Applications 24 VAC HEATING TRANSFORMER 24 VAC TRANSFORMER RH 24 VAC 120 VAC RH RC FACTORY INSTALLED JUMPER W Y W G 1 1 Optional 250W 5 watt resistor is needed only if power drops below 75 milliamps. 24 VAC 120 VAC 1 HEATING RELAY REVERSING VALVE B 2 O 1 HEATING RELAY COOLING RELAY FAN RELAY Figure 1 T201 Wiring to Heating System With Single Transformer. 2 Optional 250W 5 watt resistor is needed only if power drops below 75 milliamps. Either the B or O output will be connected to the reversing valve. Terminal A supplies 24V on a call for cooling. Terminal B supplies 24V on a call for heat. Do not connect both. Figure 2 T207 Wiring to Heating/Cooling System With Single Transformer and Reversing Valve. 221 T200 Series 24 VAC HEATING TRANSFORMER 24 VAC TRANSFORMER RH FACTORY INSTALLED JUMPER 120 VAC 24 VAC W 1 Y HEATING RELAY W G REVERSING VALVE B 1 Optional 250W 5 watt resistor is needed 1 120 VAC 24 VAC RC RH 2 O only if power drops below 75 milliamps. 1 HEATING RELAY COOLING RELAY 2 FAN RELAY Optional 250W 5 watt resistor is needed only if power drops below 75 milliamps. Either the B or O output will be connected to the reversing valve. Terminal A supplies 24V on a call for cooling. Terminal B supplies 24V on a call for heat. Do not connect both. 24 VAC HEATING 2 TRANSFORMER 24 VAC TRANSFORMER RH RC FACTORY INSTALLED JUMPER 1 Y COOLING RELAY G 120 VAC 24 VAC RC 120 VAC 24 VAC W Y 1 G 1 HEATING RELAY COOLING RELAY FAN RELAY 1 Optional 250 Ohm 5 watt resistor is needed 2 FAN RELAY only if power drops below 75 milliamps. Figure 3 T204 Wiring to Cooling System With Single Transformer. Optional 250W 5 watt resistor is needed only if power drops below 75 milliamps. If one of the secondary sides of both transformers are grounded, grounded sides must be connected together. Figure 4 T205 Wiring To Heating/Cooling System With Single Transformer. 24 VAC HEATING 2 TRANSFORMER RH 24 VAC RC FACTORY INSTALLED JUMPER 120 VAC W Y G 1 HEATING RELAY COOLING RELAY FAN RELAY 24 VAC COOLING 2 TRANSFORMER 120 VAC 1 2 AUTO FAN CONTROL TH HC RH RC W Y G B O Optional 250W 5 watt resistor is needed only if power drops below 75 milliamps. If one of the secondary sides of both transformers are grounded, grounded sides must be connected together. Figure 5 T205 Wiring To Heating/Cooling System With Dual Transformer. 222 DISPLAY HEATING OPERATING DIFFERENTIAL HEAT CONTROL TIME DELAY COOL CONTROL TIME DELAY Figure 6 Terminal Identification.