Survey
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
We break the limit, establish the horizon! SOUND SERIES LED Driver for Outdoor Lighting Constant Current HV 120W 20120515 DESCRIPTION The PLD0120-1KCH1-XXXX Series of AC/DC switching power supplies are 120 watts of constant current output power. With 160~305Vac input voltage, these units will provide up to a 3.15A of output current and a maximum output voltage of 342Vdc for 120W maximum output power. They are designed to be highly efficient and highly reliable with all-round protections: over voltage protection, over temperature protection, and short circuit protection. FEATURES • • • • • • • • • Ultra-high efficiency: up to 94% Universal AC input / High range (up to 305Vac) Active PFC function:up to 0.96 Long life time:50,000 hours High reliability:all components operate below rated temperature even at OTP High performance:small output overshoot under input surge All-round protection: OVP, OTP & SCP Lightning protection:3kV/6kV Ingress protection: IP67 SPECIFICATIONS [1] Model PLD0120-1KCH1-XXXX[5] Rated Power 120W 120W 120W 120W 120W 120W 120W 120W Output Rails 1 Rail 1 Rail 1 Rail 1 Rail 1 Rail 1 Rail 1 Rail 1 Rail Rated Current 350mA 450mA 700mA 1050mA 1400mA 2100mA 2800mA 3150mA Output Current Accuracy ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% Output Voltage 254-342V 198-266V 127-171V 85-114V 64-85V 43-57V 32-42V 29-38V Ripple & Noise (max.) [2] 52mA 105mA 157mA 210mA 315mA 420mA 472mA ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% 94% 94% 94% 93.5% 93% 67mA Load Regulation ±0.5% ±0.5% Rise Time 200ms @full load 230V/115V Turn On Delay Time Max3.0s@ full load 230Vac/50Hz Input Voltage 160~305Vac Input Frequency 47~63Hz Efficiency (typ.) 94.5% Power Factor (typ.) PF≧0.96/230Vac @full load and rated output voltage AC Current (typ.) 0.72A/230Vac 0.64A/277Vac Inrush Current 75A/230Vac, max. , cold start Leakage Current ≦0.75mA /277Vac MTBF >200 Khrs Life Time [3] >50,000hrs / full load and rated voltage @50℃ Line Regulation ±0.5% ±0.5% 94.5% 94% MIL-HDBK-217F(25℃) Operating Temperature -40℃~+60℃ +70℃ @80% load (refer to derating curve) Operating Humidity 10~100%RH Non-condensing Storage Temperature -40℃~+85℃ Storage Humidity 5~100%RH Vibration 10 ~500Hz,5G.12min/1cycle,for period 72min each along X,Y,Z axes. IP Level IP67 Protection OVP:125% output voltage;OTP;SCP Surge Voltage Differential Mode≧3KV;Common Mode≧6KV Safety Standards EN61347-1,EN61347-2-13 Dependent IP67 approved;design refer to UL60950-1;TUV60950-1 Withstand Voltage I/P-O/P 3750Vac Isolation Resistance I/P-O/P I/P-FG 100M ohm /500VDC/25℃/70%RH EMI Conduction & Radiation Compliant With EN55015 /EN55022/CISPR22 CLASS B Harmonic Current Compliant With EN61000-3-2 Class C (≧60% load) EN61000-3-3 FSP Power Solution GmbH TEL: +49 2161 495249 0 I/P-FG 3750Vac Jakobshöhe 16 41066 Mönchengladbach Germany FAX: +49 2161 495249 29 Website: www.fsp-ps.de Email: [email protected] We break the limit, establish the horizon! LED Driver for Outdoor Lighting SOUND SERIES Constant Current HV 120W 20120515 Compliant With EN61000-4-2,3,4,5,6,8,11 EMS Immunity [4] Dimension (LxWxH) 180 * 68 * 42.5, mm Net Weight 1.1Kg Packing 12PCS/BOX Notes: [1] Data at full load, 230VAC input, and 25oC ambient temperature unless otherwise specified. [2] Measured at 20MHz bandwidth@25 oC [3] Measured at full load, 230Vac input, 40℃/50℃ ambient temperature condition for models which rated power less than 100W / more than 100W. [4] Size without bracket. [5] XXXX stands by rated current. PROTECTION FUNTIONS Over voltage protection: The output voltage that triggers over voltage protection should be no higher than 125% Vout. The power supply shall enter auto-recovery mode during OVP, and return to normal operation after the power is turned on again. Over temperature protection: When the power supply enters overheating protection condition, no components should be damaged. The power supply should enter auto-recovery mode or latch mode. After the fault condition is removed, the power supply shall be operated normally after AC is turn on again. Short circuit protection: When output is being shorted, the power supply shall enter auto-recovery mode or latch mode. After the fault condition is removed, the power supply shall be operated normally after AC is turn on again. MECHANICAL OUTLINE OUTPUT 输出端 INPUT 输入端 Anode + Earth Wire ACL(BROWN) ACN(BLUE) GND(G/Y) VDE&3C H05RN-F 3*1.0mm2 橡膠線 VDE&3C H05RN-F 3*1.0mm2 橡膠線 Cathode - DERATING CURVE 100 % ) ( 载 负 80 100Vac 80 60 60 240Vac Load/ Load/ ) ( 载 负 % 100 40 40 20 20 -40 -20 0 20 40 60 100 环境温度( 环境温度(℃) Ambient Temperature/ FSP Power Solution GmbH TEL: +49 2161 495249 0 80 90 120 150 180 210 240 270 300 输入电压( 输入电压(V) Input Voltage/ Jakobshöhe 16 41066 Mönchengladbach Germany FAX: +49 2161 495249 29 Website: www.fsp-ps.de Email: [email protected] We break the limit, establish the horizon! SOUND SERIES LED Driver for Outdoor Lighting Constant Current HV 120W 20120515 CIRCUIT STRUCTURE Efficiency VS Load(2800mA Model) Efficiency Power factor % ) ( PF characteristics graph (2800mA Model) Load(%) (3150mA Model) Output current over shoot Input 115Vac/60Hz (For reference) FSP Power Solution GmbH TEL: +49 2161 495249 0 Load(%) Input Voltage transient (3150mA Model) For Low Line 80Vac~90Vac (For reference) Jakobshöhe 16 41066 Mönchengladbach Germany FAX: +49 2161 495249 29 Website: www.fsp-ps.de Email: [email protected] We break the limit, establish the horizon! LED Driver for Outdoor Lighting SOUND SERIES Constant Current HV 120W 20120515 WATERPROOF CONNECTION Waterproof connector can be assembled on the output cable to operate in dry/wet or outdoor environment. ·Ë ÀÈ ®¦ REVISION HISTORY Remarks Date Revision Section FSP Power Solution GmbH TEL: +49 2161 495249 0 From Jakobshöhe 16 41066 Mönchengladbach Germany FAX: +49 2161 495249 29 Website: www.fsp-ps.de To Email: [email protected]