Download DMS-20PC-9-DCM - Murata Power Solutions

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Studio monitor wikipedia , lookup

Current source wikipedia , lookup

Electrification wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Ohm's law wikipedia , lookup

Ground (electricity) wikipedia , lookup

Power over Ethernet wikipedia , lookup

Electric power system wikipedia , lookup

Power inverter wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Islanding wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Schmitt trigger wikipedia , lookup

Power engineering wikipedia , lookup

Solar micro-inverter wikipedia , lookup

Metadyne wikipedia , lookup

Distribution management system wikipedia , lookup

Electrical substation wikipedia , lookup

Rectifier wikipedia , lookup

Three-phase electric power wikipedia , lookup

Power MOSFET wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Multimeter wikipedia , lookup

Voltage regulator wikipedia , lookup

History of electric power transmission wikipedia , lookup

Surge protector wikipedia , lookup

Power electronics wikipedia , lookup

Opto-isolator wikipedia , lookup

Buck converter wikipedia , lookup

Stray voltage wikipedia , lookup

Power supply wikipedia , lookup

AC adapter wikipedia , lookup

Alternating current wikipedia , lookup

Electrical wiring in the United Kingdom wikipedia , lookup

Voltage optimisation wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
DMS-20PC-9-DCM
www.murata-ps.com
380V, Self-Powered, LED-Display
DC Voltage Monitor
FEATURES

Self-powered, requires only two connections

160 to 430Vdc measurement range

Ideal for 380V DC power distribution systems

Digital replacement for analog panel meters
DATEL's DMS-20PC-9-DCM self-powered, high voltage DC monitors are specifically
designed to measure and display voltages in 380V DC power-distribution systems or battery
banks. Simply connect any 160 to 430Vdc source across its rear terminals and the meters
are fully operational—no additional components or power supplies are required.

Large, easy-to-read, bright red LED display

Screw-style terminal connections simplify installation

Rugged silicone-encapsulated plastic package
Their large, 0.37"/9.4mm, red LED display can be easily
read from 15 feet away (5 meters). These meters accurately
display dc bus voltages with 1Vdc resolution. Built-in reverse
polarity protection assures simple, trouble-free installation.
All DMS-20PC-9-DCMs employ a 3½ digit A/D converter
and precision metal-film resistors to achieve outstanding
performance over an operating temperature range of –25 to
+60°C.

Reverse polarity protected to –430Vdc
Functional Specifications
Input
Voltage Range ➀
Current Consumption
@Vin = 430Vdc
Reverse Polarity Protection
Performance
Sampling Rate
Resolution
Accuracy @ +25°C
Temperature Drift
(–25 to +60°C)
Mechanical
Dimensions
Display Type
Weight
Case Material
6-32 screw torque
Environmental
Operating Temperature
Storage Temperature
Humidity (Non-condensing)
+160 to +430Vdc
3mA (max.)
-430Vdc (max.)
The meter’s electronics are housed in an encapsulated,
polycarbonate case that also provides excellent protection
against moisture, shock, and vibration. The DMS-20PC-9-DCM is
designed to fit in the same panel cutout as many of DATEL's
AC and DC voltage monitors and AC and DC ammeters; all of
your voltage and current monitoring instrumentation can now
be sourced from one supplier.
2.5 readings/second
1Vdc
±1V (typ.), ±2V (max.)
±0.4 V/°C (max.)
Typical panel mount installation and
suggested wiring (user supplied)
1.38" x 0.88" x 1.00"
3 digit, red LED, 0.37"/9.4mm
1 ounce (28 grams)
Polycarbonate
6-8 in-lbs (0.7 – 0.9N-m)
Ordering Information
–25 to +60°C
–40 to +75°C
0 to 85%
DMS-20PC-9-DCM-C
160 to 430V DC voltage monitor (Red LED)
DMS-BZL4-C
Optional panel mount bezel with sealing gasket
DMS-20-CP
Panel cutout punch
Note: Brass screws (6-32 thread) and a panel-mount retaining clip are supplied with each meter. The ‘-C’ suffix
denotes RoHS compliance.
➀ Operation and accuracy at inputs above or below this range
are not specified.
TECHNICAL NOTES
!
IMPORTANT! To ensure safe and reliable operation, DMS-20PC-9-DCM high voltage monitors must be installed and serviced by qualified technical personnel. Contact Murata
Power Solutions if there is any doubt regarding installation or operation.
1. Measurement Type: DMS-20PC-9-DCM AC voltmeters employ a precision analog-todigital converter and a stable voltage reference to measure and display voltages from
+160Vdc to +430Vdc.
2. Calibration: DMS-20PC-9-DCM voltmeters are factory calibrated; there is no provision
for calibrating units in the field.
For full details go to
www.murata-ps.com/rohs
3. Panel Installation: All electrical connections to DMS-20PC-9-DCM must be made after
the voltmeter is securely attached to the panel, and with the input DC supply de-energized (off). In high-vibration environments, adequate strain reliefs must be used on all
supply wiring. While the supplied brass retaining clip is adequate for most installations,
the DMS-BZL4-C optional bezel assembly is recommended for demanding environmental installations. (Continued on next page.)
www.murata-ps.com/support
MPM_DMS-20PC-9-DCM.A01 Page 1 of 2
DMS-20PC-9-DCM
380V, Self-Powered, LED-Display
DC Voltage Monitor
TECHNICAL NOTES, CONT.
4. Power Supply Fusing and Wiring:
DMS-20PC-9-DCM DC voltmeters are not internally fused. The supply wires
connected to its input terminals must be fused with a 0.25A/600V time
delay/time lag fuse, in accordance with applicable regulatory codes.
All supply wiring must be rated for the voltages and currents they will
conduct and comply with any code or application-mandated requirements
pertaining to the user’s specific installation. 600V, UL-rated hook-up wire
suitable for the intended application is required. The rear threaded standoff
input-terminals are to be used only for powering the meter’s internal
circuitry; they must not be used to supply power to external loads.
The recommended supply wire size is 18AWG to 22AWG (0.83mm2 to
0.325mm2) solid or stranded copper wire. The supply wires must be
properly stripped and attached to the meter’s rear terminals such that their
insulation is not pinched by the screw terminal. Recommended insulation
strip length is 0.60" (15.2mm).
MECHANICAL SPECIFICATIONS
1.30
(33.0)
–
+
DMS-20PC-9-DCM
®
®
0.04
(1.016)
0.04
(1.016)
#6-32
UNC THD
0.44
(11.2)
0.80
(20.3)
0.32
(8.1)
+
–
0.75
(19.1)
0.88
(22.4)
1.07
(27.2)
DMS-BZL4-C
Optional Bezel
0.10
(2.5)
1.63 (41.4)
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
1.38
(35.1)
0.37
(9.4)
1.00
(25.4)
#2-56 INSERT
0.156 (3.96) DEEP
Dimensions in inches (millimeters)
Tolerances: 2 PL Dec ±0.02 (±0.51)
3 PL Dec ±0.010 (±0.254)
Recommended panel cutout dimensions:
1.336 (33.93)W × 0.838 (21.29)H
Internal corner radii 0.032 (0.81) Max.
0.04
(1.016)
0.19
(4.8)
1.28
(32.5)
0.10
(2.5)
1.83 (46.5)
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2013 Murata Power Solutions, Inc.
www.murata-ps.com/support
MPM_DMS-20PC-9-DCM.A01 Page 2 of 2