Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Solutions for an aging fleet Generator Upgrades and Modernization Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. GENERATOR UPGRADES AND MODERNIZATION Presented by Michal Gawron Marketing Engineer Generator Major Services Department Siemens AG, Mülheim / Ruhr, Germany Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 2 AGENDA Introduction into generator maintenance and upgrades Targeted LTE solutions for Siemens generators Air-cooled replacement generator (Footprint™) Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 3 Introduction Into Generator Maintenance and Upgrades Actual Influence of Renewable Energies (e.g. Electricity Production in Germany in 2014) Winter Winds in Calendar Week 51 Sun and Winds in Spring at Calendar Week 11 Source: Fraunhofer-Institut für Solare Energiesysteme ISE Freiburg , 07.01.2015 • Peaks and valleys in output from renewable generation are compensated for by load variation in conventional power plants • More load variation means increased MVAR cycling, more starts/stops, prolonged stand-by • Longevity of generator components is affected. Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 4 Introduction Into Generator Maintenance and Upgrades Changing duty cycles Example: 32 Gas-Fired Power Plant Units Service Factor (Operating hours / Period hours) § New built units running in intermediate and peak load condition ( ) § Higher stresses in most generator components, e.g. windings § Faster aging and wear à Improved design and maintenance concepts are required Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 5 Introduction Into Generator Maintenance and Upgrades Typical Sources of Failures STATOR ROTOR Other 9% Slip ring 7% Exciter 3% Ground Short 8% Winding Distortion 11% Winding Cracks 8% Retaining Rings 8% Source: VGB data base Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 6 Other 18% Insulation 39% Shorted Turn 13% Damper winding / Wedges 15% AGENDA Introduction into generator maintenance and upgrades Targeted LTE solutions for Siemens generators Air-cooled replacement generator (Footprint™) Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 7 Targeted LTE Solutions for Siemens Generators Summary of product improvements J-Lead Main Connection Lead Retaining Ring Shrink Fit Pole Cross Over Gas Baffle Teflon Coated Slotliners Position in Rotor Example of Finding Description of Solution • Laminated copper • Improved geometry • Modification of shrink fit on retaining rings Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 8 • “Omega”-shaped pole cross over • Improved geometry • Two piece blocks • Non-conducting & more flex. material • Reduced friction • Teflon coating of slot liners at slot outlet Targeted LTE Solutions for Siemens Generators J-Lead Modification J-Lead (or J-Strap) Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 9 § Connects main lead via radial bolt to the winding pole § Subject to cyclic stresses Targeted LTE Solutions for Siemens Generators Stresses / Loading on J-Lead Axial loading on J-lead due to expansion of Rotor windings • Highest loading at high VAR loading • Load cycling increases cyclic stresses on J-lead Radial loading on winding due to centrifugal loading at speed • Frequent cycling of unit increases cyclic stresses on J-lead • Over-speed increase loading on J-lead Stress concentrations due to geometry Material variations, assembly variations, and operation can affect cyclic life of J-strap Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 10 Deflection of J-Strap during standstill and operation (exaggerated) Laminated Top Connected J-Strap Laminated Bottom Connected J-Strap Targeted LTE Solutions for Siemens Generators J-Lead Design Improvements Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 11 Targeted LTE Solutions for Siemens Generators Retaining Ring Shrink Fit Modification Rotor tooth-tops Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 12 § Support the retaining ring on the rotor body § Rotor teeth area subjected to shrink fit of retaining ring § Subject to cyclic stresses Targeted LTE Solutions for Siemens Generators Loads and Stresses on Rotor Tooth Tops Compressive loads at standstill from shrink fit Axial loads from locking key Tensile loads at running speed from slot content centrifugal force Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 13 Stress concentration at fillet radii and holes Targeted LTE Solutions for Siemens Generators Shrinkfit Modification of Rotor Tooth Tops Remove tooth tops outboard of keyway • Removes majority of cracking & fatigued material at crack tip • Transfer slot load from rotor to retaining ring • Removes centrifugal loading on vent holes Machine fillet enlargement inboard of keyway • Removes shallow cracks & fatigued material • Relieve the outboard land surface of the end wedges Modifiy shrink fit on retaining rings • Replace retaining rings as necessary • Improve shrink fit characteristics Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 14 Targeted LTE Solutions for Siemens Generators Retaining Ring Inspection Rotor retaining rings Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 15 § Subjected to Stress Corrosion Cracking (SCC) § Periodic inspection of 18-5 material is necessary § Periodic inspection of 18-18 material may be recommended, depending on operating conditions Targeted LTE Solutions for Siemens Generators Automated Retatining Ring Inspection In-Situ Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 16 In the factory Targeted LTE Solutions for Siemens Generators Slot Liner Upgrade Rotor slot liner Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 17 § Slot liner wears off due to thermal cycles § Slot liner wears off during turning gear operation § Insulation between rotor coils and rotor body compromised Targeted LTE Solutions for Siemens Generators Reliability issue: Slot cell abrasion Signs of abrasion at slot channel insulation and slot cells at end of rotor body Abrasion rate is correlated to: • Deflection of the rotor (D² x L4 / I) • Time of turning-gear operation (HT) • Speed of turning-gear operation (NT) Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 18 AGENDA Introduction into generator maintenance and upgrades Targeted LTE solutions for Siemens generators Air-cooled replacement generator (Footprint™) Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 19 Air Cooled Replacement Generator Typical auxiliary systems in a generator with Hydrogen / Water cooling • Hydrogen gas system Provides cooling medium (H2) inside the generator • Seal oil system Keeps the hydrogen gas inside stator frame • Gas inertization system Required for de-gassing generator during stand-stills • Stator winding cooling water system (> 200MW) Provides cooling medium (Water) for direct cooling of stator winding With the FootprintTM Generator these auxiliary systems are not required and can be eliminated saving life cycle costs Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 20 Air Cooled Replacement Generator Typical age related problems in auxiliary systems Corrosion Leaking Components Porous Seal Lost Tagging Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 21 Wear and Tear Vibration Air Cooled Replacement Generator Overview of design features The radially direct cooled stator core provides maximum heat transfer capability for the stator winding with minimum flow resistance for the overall cooling circuit. The use of different cooling zones in the active part of the generator yields a more uniform temperature profile. Cooler cover with 4x25% drop in vertical coolers, site installed for easy shipment of the core generator and easy maintenance . The assembled winding is using the proven MICALASTIC® insulation system with global vacuum-pressure impregnation technology providing maximum electrical endurance. Improved enclosure design makes these air-cooled turbogenerators suitable for outdoor installation, allows sound pressure levels down to 85db(A) and provides easy access to all relevant components Mechanically decoupled stator end winding system with maximum rigidity to withstand transient system faults and maximum flexibility for thermal expansion. Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 22 The maintenance-free stator core is flexibly mounted to the outer casing with flex plates. This prevents vibrations at double rotational frequency from impacting the outer casing and thus the foundation tabletop. Air Cooled Replacement Generator FootprintTM Approach Adaptation of base frame • Customized base frame fits existing foundation dimensions / No foundation mods requried • Generator can be installed more quickly Adaptation of stator core and rotor shaft • Stator winding insulation with global vacuum pressure impregnation (GVPI) • Rotor shaft and coupling are adapted • Plug-in or pedestal bearings • Rotor-dynamic calculation of shaft train Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 23 Air Cooled Replacement Generator FootprintTM Approach Adaptation of excitation • Excitation can be static or brushless • Reduced operating costs with new exciter Adaptation of bushings • Downward • To the side • Or upward through the cover Adaptation options for cooling • Location and configuration of the cooler can be varied • Typically use Totally Enclosed Water to Air Cooling • Water demand no greater than for existing Hydrogen coolers Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 24 Air Cooled Replacement Generator Customer benefits Elimination of auxiliary systems • Increased safety by eliminating hydrogen • Reducing operation complexity and cost Built-to-function design • Cyclic operation modes • Peaking mode operation • Multiple start/stop cycles Highest Reliability/ Availability • Over 98% availability • Standard spare parts only, i.e. always stocked • Major inspection intervals can be spread over 12 years Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 25 Air Cooled Replacement Generator Case study – South Africa Unit Existing Units Replacement FootPrintTM Generator Manufacturer AEG (1964) Siemens Reactive Power [MVA] 139 139 Active Power [MW] 125,1 125,1 Power Factor 0,9 0,9 Rated Voltage [kV] 10,5 12,5 Primary Cooling Medium H2 Air Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 26 CONTACT PAGE Michal Gawron Marketing Engineer Generator Major Services Europe, Africa, Asia-Pacific Phone: +49 (208) 456 8134 Fax: +49 (208) 456 8137 Mobile: +49 (173) 317 6546 E-mail: [email protected] Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 27 BACK-UP Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 28 Air Cooled Replacement Generator Micalastic® experience base § The Micalastic® is used in Siemens generators for more than 50 years. § In addition Siemens introduced the Global Vacuum Pressure Impregnation (GVPI) Technology in 1988. § Since then Siemens has manufactured more than 1000 generators (air-, hydrogen- and hydrogen/water cooled) using GVPI technology in conjunction with the Micalastic insulation system with voltage levels up to 22 kV and rating up to 550 MVA. § Operational experience of these units without any stator insulation based failures since the beginnings in 1988 demonstrates the superior quality of GVPI technology. Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 29 Targeted LTE Solutions for Siemens Generators Product Bulletin – New J-Lead Summary The two J-Leads which connect the radial leads to the rotor winding can suffer fatigue- induced cracking. In order to avoid any forced outages and potential consequential damage resulting from such cracking, Siemens has developed improved J-Lead assemblies as part of its ongoing product development process and in order to increase reliability. Siemens recommends that the old type of J-Lead be replaced with these improved J-Lead assemblies. Please ask your Siemens representative or check on our service customer portal if this product bulletin applies to a generator you have in operation. Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 30 Targeted LTE Solutions for Siemens Generators Product Bulletin – Short Ring Modification Summary The rotor tooth tops underneath the retaining rings are subject to cracking. In order to prevent the initiation of cracks and to reduce the impact of any existing cracks a “short ring modification” has been developed by Siemens and it is recommended that this measure be implemented in order to increase reliability. This modification also encompasses machining of the shrink fit of the retaining ring, the rotor tooth tops and the retaining ring itself. In order to perform this modification it is necessary to remove both retaining rings and remove the rotor from the stator. Please ask your Siemens representative or check on our service customer portal if this product bulletin applies to a generator you have in operation. Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 31 Targeted LTE Solutions for Siemens Generators Product Bulletin – Inspection Recommendation for Retaining Rings Summary A periodic inspection of 18Mn-18Cr1 retaining rings and a qualified NonDestructive Examination (NDE) procedure are recommended on all generator rotors. This inspection is intended to evaluate the structural integrity of non-magnetic retaining rings and zone rings. Siemens may recommend replacement of retaining rings in cases of inspection findings or exceptional operating conditions. Cases that might be considered “exceptional conditions” include: • Stress corrosion cracking due to chemical conditions that should not be the normal operating environment of large electrical generators. These include long-term exposure to saturated sodium chloride solution and exposure to bromine under electrical fault conditions. • Grid interaction with the generator (such as disturbances from electric arc furnaces), which can result in rotor torsional oscillations. • Loss-of-control events, such as out-of phase synchronization, sudden short circuit, motorization and similar severe abnormal operation. Please ask your Siemens representative or check on our service customer portal if this product bulletin applies to a generator you have in operation. Unrestricted © Siemens Osakeyhtiö 2015. All rights reserved. Page 32