Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Input Optocoupler Termina l Blocks DEK-OE . . . and DEK-OE . . ./T Power Optocoupler Termina l Blocks DEK-OV . . . Type of housin g Polyamide PA non-reinforced, see page 439 color: gree n Torque value of terminals, see page 441 . For marking systems and mounting material, see CLIPLIN E catalog. The rated cross section (see page 441) refers to untreated conductors without ferrules . For the protection of input and output, inductive loads must b e dampened with an effective protection circuit . Phoenix DEK-OE interface terminal block s are only 6 .2 mm wide but still provide a complete input interface with : —electrical isolation between input an d output at up to 2 .5 kV rms , —polarized due to a polarity protection diod e and/or bridge rectifier in the input circuit , —light indicator for signalizing the switchin g status . The interface terminal blocks are fitted wit h an optocoupler . Signal matching takes plac e inside the interface terminal block itself . Thi s allows simple and low-cost installation on th e terminal strip, the natural control cabine t interface . The versions for peripheral voltages o f 24 V DC, 48 V DC and 125 V DC also have the option of separating the output voltag e from the optocoupler . This can be recognized by the isolating connector on th e upper surface of the terminal block . All interface connections provide modula r terminal block convenience . They can b e labeled according to the standard so they can be recorded in equipment documentation in the normal way. The wid e range of modular terminal block accessories includes the EB-DIK insertion bridge fo r bridging voltage potentials . Individual interface channels can b e labeled using Phoenix standard labelin g materials (ZB 6, DS 6, etc .) . This all means the new interface termina l blocks offer the following advantages : —neutral, space-saving interface in th e terminal strip between the automatio n device and peripheral components , — labeling and mounting with th e convenience of modular terminal blocks , — possibility of combination with standar d modular terminal blocks in a terminal strip . 70 Phoenix Contact High capacity interface modules are necessary for directly switching actuators and positioners, such as contactors , solenoid valves or motors, using economi c digital output cards (low capacity, n o electrical isolation but a large number of positions) . The Phoenix interface terminal block s DEK-OV provide a complete output interfac e on the basis of a 6 .2 mm wide modula r terminal block . The most important feature s of the power optocoupler are : —wear-free switching up to 24 V DC/10 A and 240 V AC/800 mA , —status display via LED, —electrical isolation between the input an d output 2 .5 kV, —integrated protection circuit on the outpu t side , —zero voltage switch at AC output , —assembly and labeling as with modula r terminal blocks , —bridging with the insertion bridges EB-DIK , —ambient temperature range -20°C to +60°C , —also available as an actuator version . OM 8 3* (IEC) [mm 2 ] ) Connection data rigi d solid flexibl e stranded AW G 0 .2-2 .5 0 .2-2 .5 24-14 max. torque 0 .8 N m clus (for DEK-OE- 24DC/48DC/100 ) (for DEK-OE-120AC/48DC/100 ) Description Input voltage 5VL 12 V C 24 V DL 60 V DC 120 V AC 230 V AC Input optocoupler terminal block, Input : DC or AC voltage Output: DC voltage Input optocoupler terminal block, with isolating connector in the output, Input DC voltage Output: DC voltage (1) Insertion bridges ), for middle and bottom level divisible 24 V DC 48 V DC 125 V DC color : red red red red red 2-pos. 3-pos. 4-pos. 5-pos. 10-pos. blue blue blue blue blue 2-pos. 3-pos. 4-pos. 5-pos. 10-pos. blue red white 80-pos. 80-pos. 80-pos. Input data Operating voltage range [V DCN AC ] Switching level 1 signal ("H" ) 0 signal ("L" ) Current at nominal voltage [mA] Transmission frequency flimlt [Hz] (ohmic load ) Input circui t Output data Operating voltage rang e Continuous load current Leakage current at input "L" Residual voltage drop at "H " Pickup dela y Switch-off delay Output connectio n Output circui t 1)The maximum current carrying capacity of the bridge should b e taken into account for the current requirements and the numbe r of connected inputs or outputs. The power may only be fed directly to the insertion bridge . Output resisto r General dat a Test voltage input/output Ambient temperature rang e Standards/regulation s 2) With the 120 V AC and 230 V AC types, the housing is open on one side. Here cover D-DEK 1,5 GN (Order No . 27 16 94 9) i s additionally required. Installation position Mounting Connection type , co N DEK-OE . . . DEK-OE- . . . R DC voltage output, max. 100 mA DC voltage output, max . 100 m A Terminal width 6 .2 enclosed housing Terminal width 6 .2 enclosed housing Al A2 Al l A2 DC inpu t Al A2 / . Al 14 A2 AC input Type Order No. K-OE- MC/480C/10 0 K-OE- 12DC/48DC/10 0 DEK-OE- 24DC/48DC/10 0 DEK-OE- 60DC/48DC/10 0 DEK-OE-120AC/48DC/100 2) DEK-OE-230AC/48DC/100 2) 29 40 22 29 64 48 29 40 20 29 41 53 29 41 65 29 40 21 3 7 7 6 9 0 Pcs . Pkt. Type Order No . Pcs . Pkt . DEK-OE- 24DC/48DC/100/T DEK-OE- 48DC/48DC/100/T DEK-OE-125 D C/48DC/100/T 29 64 25 4 29 40 28 1 29 40 29 4 10 10 10 10 10 10 10 10 10 EB 2-DIK RD EB 3-DIK R D EB 4-DIK R D EB 5-DIK R D EB 10-DIK R D I rnax 26 26 26 26 26 A A A A A 271669 271674 271675 271676 27 16 77 3 5 8 1 4 100 100 100 100 10 EB 2-DIK R D EB 3-DIK R D EB 4-DIK R D EB 5-DIK R D EB 10-DIK R D I rnax 26 26 26 26 26 A A A A A 271669 271674 271675 271676 271677 3 5 8 1 4 10 0 10 0 10 0 10 0 10 EB 2-DIK B U EB 3-DIK B U EB 4-DIK B U EB 5-DIK B U EB 10-DIK BU 26 26 26 26 26 A A A A A 27 16 64 271665 271666 271667 271668 8 1 4 7 0 10 0 10 0 10 0 10 0 10 EB 2-DIK B U EB 3-DIK B U EB 4-DIK B U EB 5-DIK B U EB 10-DIK BU 26 26 26 26 26 A A A A A 271664 8 271665 1 271666 4 271667 7 271668 0 10 0 10 0 10 0 10 0 10 EB 80-DIK BU 26 A 271594 0 5 EB 80-DIK R D 26 A 271595 3 5 EB80-DIKWH 26A 2715788 5 DC AC 5±10% 12±20% 24±20% 60±20% 120±10% 230±10% 0 .8 x UN 207 0 .4 x UN 92 7 11 7 4 4 3 300 300 300 300 3 3 operation indicator, polarity protection , surge voltage protection (with AC input only ) EB 80-DIK BU 26 A 271594 0 EB 80-DIK RD 26 A 271595 3 EB 80-DIK WH 26 A 2715788 DC 24±20% 48±10% 125±10% ?0 .8xU N >—40 ?10 0 >0 .4xU N ±19 ±50 6 .5 5 3 200 200 200 operation indicator (LED), polarity protection, bridge rectifie r 3 .. .48 V D C 100 mA /_10µA approx . 0 .9 V approx . 20 IS (DC) / 2 ms (AC ) approx . 200 ps (DC) / 10 ms (AC ) conductor — ground referenced / 2-conductor — floatin g mping diode, polarity protection diod e 3 . . . 48 V D C 100 m A 10µA approx . 0 .9 V approx . 40 p s approx . 40 p s 2-conductor — floating polarity protection, surge voltage protection , disconnection of the output via isolating connecto r 5 5 approx . 22 kQ2 with 3-conductor operatio n 2 .5 kV, 50 Hz, 1 min. -20°C up to +60°C 1E0 60 664/IEC 60 664 A/DIN VDE 011 0 any in rows with zero spacin g screw connection 2 .5 kV, 50 Hz, 1 min. -20°C up to +60°C IEC 60 664/IEC 60 664 A/DIN VDE 0110 , contamination class 2, surge voltage category II I any in rows with zero spacing screw connection Phoenix Contact 71