Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Input Optocoupler Termina l
Blocks
DEK-OE . . . and DEK-OE . . ./T
Power Optocoupler Termina l
Blocks
DEK-OV . . .
Type of housin g
Polyamide PA non-reinforced,
see page 439
color: gree n
Torque value of terminals, see page 441 .
For marking systems and mounting material, see CLIPLIN E
catalog.
The rated cross section (see page 441) refers to untreated
conductors without ferrules .
For the protection of input and output, inductive loads must b e
dampened with an effective protection circuit .
Phoenix DEK-OE interface terminal block s
are only 6 .2 mm wide but still provide a
complete input interface with :
—electrical isolation between input an d
output at up to 2 .5 kV rms ,
—polarized due to a polarity protection diod e
and/or bridge rectifier in the input circuit ,
—light indicator for signalizing the switchin g
status .
The interface terminal blocks are fitted wit h
an optocoupler . Signal matching takes plac e
inside the interface terminal block itself . Thi s
allows simple and low-cost installation on th e
terminal strip, the natural control cabine t
interface .
The versions for peripheral voltages o f
24 V DC, 48 V DC and 125 V DC also have
the option of separating the output voltag e
from the optocoupler . This can be
recognized by the isolating connector on th e
upper surface of the terminal block .
All interface connections provide modula r
terminal block convenience . They can b e
labeled according to the standard so they
can be recorded in equipment
documentation in the normal way. The wid e
range of modular terminal block accessories
includes the EB-DIK insertion bridge fo r
bridging voltage potentials .
Individual interface channels can b e
labeled using Phoenix standard labelin g
materials (ZB 6, DS 6, etc .) .
This all means the new interface termina l
blocks offer the following advantages :
—neutral, space-saving interface in th e
terminal strip between the automatio n
device and peripheral components ,
— labeling and mounting with th e
convenience of modular terminal blocks ,
— possibility of combination with standar d
modular terminal blocks in a terminal strip .
70
Phoenix Contact
High capacity interface modules are
necessary for directly switching actuators
and positioners, such as contactors ,
solenoid valves or motors, using economi c
digital output cards (low capacity, n o
electrical isolation but a large number of
positions) .
The Phoenix interface terminal block s
DEK-OV provide a complete output interfac e
on the basis of a 6 .2 mm wide modula r
terminal block . The most important feature s
of the power optocoupler are :
—wear-free switching up to 24 V DC/10 A and
240 V AC/800 mA ,
—status display via LED,
—electrical isolation between the input an d
output 2 .5 kV,
—integrated protection circuit on the outpu t
side ,
—zero voltage switch at AC output ,
—assembly and labeling as with modula r
terminal blocks ,
—bridging with the insertion bridges EB-DIK ,
—ambient temperature range -20°C to
+60°C ,
—also available as an actuator version .
OM
8
3*
(IEC)
[mm 2 ]
)
Connection data
rigi d
solid
flexibl e
stranded
AW G
0 .2-2 .5
0 .2-2 .5
24-14
max. torque 0 .8 N m
clus
(for DEK-OE- 24DC/48DC/100 )
(for DEK-OE-120AC/48DC/100 )
Description
Input voltage
5VL
12 V C
24 V DL
60 V DC
120 V AC
230 V AC
Input optocoupler terminal block,
Input : DC or AC voltage
Output: DC voltage
Input optocoupler terminal block,
with isolating connector in the output,
Input DC voltage
Output: DC voltage
(1) Insertion bridges ), for middle and
bottom level
divisible
24 V DC
48 V DC
125 V DC
color :
red
red
red
red
red
2-pos.
3-pos.
4-pos.
5-pos.
10-pos.
blue
blue
blue
blue
blue
2-pos.
3-pos.
4-pos.
5-pos.
10-pos.
blue
red
white
80-pos.
80-pos.
80-pos.
Input data
Operating voltage range [V DCN AC ]
Switching level 1 signal ("H" )
0 signal ("L" )
Current at nominal voltage [mA]
Transmission frequency flimlt [Hz] (ohmic load )
Input circui t
Output data
Operating voltage rang e
Continuous load current
Leakage current at input "L"
Residual voltage drop at "H "
Pickup dela y
Switch-off delay
Output connectio n
Output circui t
1)The maximum current carrying capacity of the bridge should b e
taken into account for the current requirements and the numbe r
of connected inputs or outputs. The power may only be fed
directly to the insertion bridge .
Output resisto r
General dat a
Test voltage input/output
Ambient temperature rang e
Standards/regulation s
2) With the 120 V AC and 230 V AC types, the housing is open on
one side. Here cover D-DEK 1,5 GN (Order No . 27 16 94 9) i s
additionally required.
Installation position
Mounting
Connection type
,
co
N
DEK-OE . . .
DEK-OE- . . . R
DC voltage output, max. 100 mA
DC voltage output, max . 100 m A
Terminal width 6 .2
enclosed housing
Terminal width 6 .2
enclosed housing
Al
A2
Al l
A2
DC inpu t
Al
A2 / .
Al
14
A2
AC input
Type
Order No.
K-OE- MC/480C/10 0
K-OE- 12DC/48DC/10 0
DEK-OE- 24DC/48DC/10 0
DEK-OE- 60DC/48DC/10 0
DEK-OE-120AC/48DC/100 2)
DEK-OE-230AC/48DC/100 2)
29 40 22
29 64 48
29 40 20
29 41 53
29 41 65
29 40 21
3
7
7
6
9
0
Pcs .
Pkt.
Type
Order No .
Pcs .
Pkt .
DEK-OE- 24DC/48DC/100/T
DEK-OE- 48DC/48DC/100/T
DEK-OE-125 D C/48DC/100/T
29 64 25 4
29 40 28 1
29 40 29 4
10
10
10
10
10
10
10
10
10
EB 2-DIK RD
EB 3-DIK R D
EB 4-DIK R D
EB 5-DIK R D
EB 10-DIK R D
I rnax 26
26
26
26
26
A
A
A
A
A
271669
271674
271675
271676
27 16 77
3
5
8
1
4
100
100
100
100
10
EB 2-DIK R D
EB 3-DIK R D
EB 4-DIK R D
EB 5-DIK R D
EB 10-DIK R D
I rnax 26
26
26
26
26
A
A
A
A
A
271669
271674
271675
271676
271677
3
5
8
1
4
10 0
10 0
10 0
10 0
10
EB 2-DIK B U
EB 3-DIK B U
EB 4-DIK B U
EB 5-DIK B U
EB 10-DIK BU
26
26
26
26
26
A
A
A
A
A
27 16 64
271665
271666
271667
271668
8
1
4
7
0
10 0
10 0
10 0
10 0
10
EB 2-DIK B U
EB 3-DIK B U
EB 4-DIK B U
EB 5-DIK B U
EB 10-DIK BU
26
26
26
26
26
A
A
A
A
A
271664 8
271665 1
271666 4
271667 7
271668 0
10 0
10 0
10 0
10 0
10
EB 80-DIK BU
26 A
271594 0
5
EB 80-DIK R D
26 A
271595 3
5
EB80-DIKWH
26A
2715788
5
DC
AC
5±10% 12±20% 24±20% 60±20% 120±10% 230±10%
0 .8 x UN
207
0 .4 x UN
92
7
11
7
4
4
3
300
300
300
300
3
3
operation indicator, polarity protection ,
surge voltage protection (with AC input only )
EB 80-DIK BU
26 A
271594 0
EB 80-DIK RD
26 A
271595 3
EB 80-DIK WH
26 A
2715788
DC
24±20%
48±10%
125±10%
?0 .8xU N
>—40
?10 0
>0 .4xU N
±19
±50
6 .5
5
3
200
200
200
operation indicator (LED), polarity protection, bridge rectifie r
3 .. .48 V D C
100 mA
/_10µA
approx . 0 .9 V
approx . 20 IS (DC) / 2 ms (AC )
approx . 200 ps (DC) / 10 ms (AC )
conductor — ground referenced / 2-conductor — floatin g
mping diode, polarity protection diod e
3 . . . 48 V D C
100 m A
10µA
approx . 0 .9 V
approx . 40 p s
approx . 40 p s
2-conductor — floating
polarity protection, surge voltage protection ,
disconnection of the output via isolating connecto r
5
5
approx . 22 kQ2 with 3-conductor operatio n
2 .5 kV, 50 Hz, 1 min.
-20°C up to +60°C
1E0 60 664/IEC 60 664 A/DIN VDE 011 0
any
in rows with zero spacin g
screw connection
2 .5 kV, 50 Hz, 1 min.
-20°C up to +60°C
IEC 60 664/IEC 60 664 A/DIN VDE 0110 ,
contamination class 2, surge voltage category II I
any
in rows with zero spacing
screw connection
Phoenix Contact
71