DAR 7 / DAR 25 / DAR 40 / DAR 60 / DAR 120 Pressure transmitter in stainless steel construction 14114422.05 01/2017 View Features Dimensions Universal pressure transmitters for measuring pressure in liquid and gaseous media in refrigeration systems Conversion of pressure into standardised electrical current signal 4...20 mA Following designs for different measurement ranges DAR 7 -0,5...7 bar = 4...20 mA DAR 25 0...25 bar = 4...20 mA DAR 40 0...40 bar = 4...20 mA DAR 60 0...60 bar = 4...20 mA DAR 120 0...120 bar = 4...20 mA Compact design with integrated signal amplifier Polarity-safe, plug-in connection via two-wire pre-assembled connecting cable (3.5m) with M12 connector plugs All welded metal measuring cell with high overload safety No mechanical ageing, high temperature resistance Media compatibility with all standard refrigerants including propane / R290, propene / R1270, ammonia / R717 and carbon dioxide / R744 Thread standardised for refrigeration equipment (7/16"-20UNF-2A or 1/4"-NPT) 3.5 m cable with connector plug Dimensions 3.5 m cable with connector plug Characteristic curves Current I / mA 4 5 6 7 8 9 10 11 DAR 7 p / bar -0,50 -0,03 0,44 0,91 1,38 1,84 2,31 2,78 DAR 25 p / bar 0,00 1,60 3,10 4,70 6,30 7,80 9,40 10,90 DAR 40 p / bar 0,00 2,50 5,00 7,50 10,00 12,50 15,00 17,50 DAR 60 p / bar 0,00 3,80 7,50 11,30 15,00 18,80 22,50 26,30 DAR 120 p / bar 0,00 7,50 15,00 22,50 30,00 37,50 45,00 52,50 Current I / mA 12 13 14 15 16 17 18 19 20 DAR 7 p / bar 3,25 3,72 4,19 4,66 5,13 5,59 6,06 6,53 7,00 DAR 25 p / bar 12,50 14,10 15,60 17,20 18,80 20,30 21,90 23,40 25,00 DAR 40 p / bar 20,00 22,50 25,00 27,50 30,00 32,50 35,00 37,50 40,00 DAR 60 p / bar 30,00 33,80 37,50 41,30 45,00 48,80 52,50 56,30 60,00 DAR 120 p / bar 60,00 67,50 75,00 82,50 90,00 97,50 105,00 112,50 120,00 DAR 7 / DAR 25 / DAR 40 / DAR 60 DAR 120 DARxxx_2017-01_EN Subject to technical changes Page 1 of 2 DAR 7 / DAR 25 / DAR 40 / DAR 60 / DAR 120 Pressure transmitter in stainless steel construction 14114422.05 01/2017 Installation and safety instructions Technical data Please make sure before installation, commissioning and operation that the appropriate pressure transmitter has been selected in terms of measuring range, design and wetted materials (corrosion) that must be qualified for the specific measuring conditions. Furthermore the corresponding national safety regulations (e.g. VDE 0100) have to be observed! Non-observance can result in serious injury and/or damage to the equipment. For hazardous media such as oxygen, acetylene, flammable or toxic gases or liquids, and refrigeration plants, compressors, etc., in addition to all standard regulations the appropriate existing codes or regulations must also be followed. Residual media in dismounted pressure transmitters can result in a risk to persons, the environment and equipment. Take sufficient precautionary measures. Supply voltage (output signal contact voltage UB) Electrical connection via preassembled cable (3.5m) and M12 connector plug Output Any operation other than the one described is regarded as improper and must be avoided. If faults cannot be eliminated shut down the device immediately and secure it from being put back into operation inadvertently. Repairs must only be carried out by the manufacturer. Interferences or changes at the equipment are inadmissible. Open the connections only after the system has been depressurised. Installation and maintenance works of pressure transducers may be carried out only by skilled personnel authorized by the plant operator. Do not exceed the overload limit of the corresponding measurement range or pressure transmitter! The pressure transmitters are connected to the refrigerant circuit via the standard thread. Installation requires a 24mm open-end wrench, which is to be operated with the maximum tightening torque of 20Nm. To avoid condensation on the housing and thus possible penetration of moisture inside the sensor, care mus be taken that the pressure transmitter housing always has a temperature above the current dew point. The thermal influence on the pressure transmitter via the pipelines mus be kept as low as possible. Pipeline section without insulation for thermal adaptation to ambient temperature Insulated pipeline section It is therefore not permitted, for example, to install the pressure transmitter directly to suction headers or other lines with large pipe cross sections. The connection should always be effected via a non-insulated line with a minimum Øinside of 4mm and a minimum length of 200 mm. Electrical cable connection is made via a presassembled cable with a standardised M12 connector plug. Damage to the cable insulation can result in leaking and thus water penetration and false measurement results. DARxxx_2017-01_EN Fluid temperature: Ambient temperature: Measurement range (in bar): Overload limit (in bar): Allowable max. load: Settling time (10…90%): Accuracy: at 25°C → at 0°C → at -20°C → BFSL → stability acc. to DIN61298-2:1995 Short-circuit strength: Inverse-polarity protection: Overvoltage protection: Insulationvoltage: Protection class: DAR 7 / DAR 25 DAR 40 / DAR 60 / DAR 120 Weight: Thread: DAR 7 / DAR 25 / DAR 40 / DAR 60 DAR 120 CE conformity 7 - 30 VDC brown (BW) supply voltage + (7...30VDC) - PIN 1 white (WH) measurement signal (4...20mA) - PIN 3 4...20mA two-wire, reverse-polarity-proof (load-independent current in power supply) -40...+100°C -30...+85°C DAR 7 DAR 25 DAR 40 DAR 60 -0,5...7 0...25 0...40 0...60 DAR 7 DAR 25 DAR 40 DAR 60 20 bar 50 bar 80 bar 120 bar RA <= (UB- 7V) / 0,02 A <= 5 ms DAR 7 DAR 25 DAR 40 DAR 60 ±0,8%, ±0,8%, ±0,8%, ±0,8%, ±1,0%, ±1,3%, ±1,0%, ±1,0%, ±1,2% ±1,8% ±1,2% ±1,2% ±0,4% ±0,4% ±0,4% ±0,4% ±0,2% ±0,2% ±0,2% ±0,2% Total of linearity, hysteresis and repeatability S+ about 0V UB about 0V Max. DC 36V DC 500V DAR 120 0...120 DAR 120 3 20 bar DAR 120 ±0,8%, ±1,0%, ±1,2% ±0,4% ±0,2% IP65 (in plugged-in condition) IP67 (in plugged-in condition) approx. 80 g 7/16"-20UNF-2A, length 15 mm 1/4"-NPT, length 13 mm EMC directive 2014/30/EU, Emissions EN 61326 (group 1; class B) and resistance to interference (industrial sector) Please also observe the technical documentation of the measurement or control electronics used. The document will automatically become invalid when superseded by a new technical description of the devices. Subject to technical changes Page 2 of 2