Doepke The experts in residual current protection technology DATA SHEET HS 3-230AC/40-20 with coil voltage 230 V AC Article number 09980439 Internetlink symbolic image Function Installation contactors are electromagnetically operated switches. If a control current flows through the magnetic coil, the main circuit closes the magnetic energiser. As long as the control current flows, the switch-on position is maintained. If the control current is interrupted, a spring forces the disconnection o return of the contacts to their original position. This design means that contactors ensure a galvanic separation between the control circuit and the switched circuit whilst simultaneously allowing high currents to be switched. Installation contactors are only designed in a limited way for release and must be protected against overload and short-circuits by upstream protective devices. Installation contactors in series HS for installation in distribution boards are extremely quiet and have very low-noise switching processes, are highly versatile thanks to their utilization categories and have a long mechanical and electrical service life. The magnetic coil of this series is suitable for continuous operation (100% duty cycle). Devices in this design are operated with a control voltage of 230 V AC. Features wide range of different contacts, high electrical and mechanical endurance, extremely quiet, suitable auxiliary switch and seal cap available Mounting quick fastening to mounting rail, any installation position Applications Installation contactors are frequently used in residential and purpose-built buildings as well as industrial facilities. They take on the switching of incandescent lamps, fluorescent lamps, transformers for halogen low-voltage lamps, mercury vapour high-pressure lamps (HQL, HPL), metal halide lamps (HQI, HPI), sodium vapour, low and high-pressure lamps, storage heaters or drives (motors). Notes The designation for the devices in this series includes both the rated current (first group of digits) and the contact design (final group of digits). A HS 25-31 therefore has a rated current of 25 A, three normally opened contacts and one normally closed contact, At ambient temperatures above 40 °C, we recommend using the RD 05 spacer. Accessories HSH 11, HS P-40/63, RD 05 Technical Data Technical Data Series Rated voltage (AC) Rated frequency Rated power (switch on) rated power (retaining) Specification contact assignment (detailed) Rated voltage (AC) Overvoltage class Rated current (AC) 2017_03_29 HS 3-230AC/40-20 HS 3 Control input 230 V 50 Hz/60 Hz 33 VA ... 45 VA 5 VA ... 7 VA Load circuit Switching contact 2 NO 400 V I, II, III 40 A doepke_09980439_dbl_en.pdf 1/3 Doepke The experts in residual current protection technology Technical Data Rated insulation voltage Switching frequency Allowed utilization category Power dissipation per pole AC-1 rated short-circuit current "r" rated short-circuit current "Iq" Rated voltage AC-1 (fix) max. Output O1 Rated power AC-1 230 V Rated voltage AC-3 one-phase (fixed) max. Output O1 Rated power AC-3 230 V max. Output O1 rated power glow lamps max. Output O1 Rated power fluorescent lamp compensated max. Output O1 Rated power fluorescent lamp not compensated max. Output O1 rated power fluorescent lamps duo-switching contact endurance AC-1 contact endurance AC-3 Duration of light arcs Switching delay, open Switching delay, close Allowed types of wires Max number of wires per terminal Cross section solid Connecting capacity flexible Cross section stranded Allowed types of wires Max number of wires per terminal Cross section solid Connecting capacity flexible Cross section stranded General data description Duty cycle Operating position Mechanical endurance Electrical endurance textual ambient temperature Housing type Mounting type Housing material Protection class Width 2017_03_29 HS 3-230AC/40-20 440 V max. 600 / h AC-1, AC-2, AC-3 3W 3 kA 10 kA 230 V 9 kW 230 V 2.6 kW 6000 VA 2805 VA 2975 VA 5280 VA 100000 Schaltspiele 150000 Schaltspiele 10 ms ... 15 ms 6 ms ... 13 ms 11 ms ... 15 ms Screw-type terminal top and bottom (Load circuit) Aluminium conductors, Copper conductors, massive conductors, flexible conductors 1 1-wire: 2.5 mm² ... 25 mm² 1-wire: 2.5 mm² ... 16 mm² 1-wire: 2.5 mm² ... 25 mm² Screw-type terminal top and bottom (Control input) Aluminium conductors, Copper conductors, massive conductors, flexible conductors 1 1-wire: 0.75 mm² ... 2.5 mm² 1-wire: 0.5 mm² ... 2.5 mm² 1-wire: 0.75 mm² ... 2.5 mm² General data continuous operation (Duty cycle ≤ 100 %) any min. 10 · 10⁶ cycles min. 1 · 10⁶ cycles 60°C when installed individually Distributor housing Mounting rail Thermoplastic resin IP20 52.5 mm doepke_09980439_dbl_en.pdf 2/3 Doepke The experts in residual current protection technology Technical Data HS 3-230AC/40-20 85 mm 65 mm 60 mm 3 EN 60715, EN 60947-4-1, VDE 0660-102 3 Height Depth Installation depth Width (modules) Design requirements/Standards Degree of pollution according to EN 60664 Dimensions Wiring example Dimensional drawing Group view STEP file Wiring diagram 2017_03_29 doepke_09980439_dbl_en.pdf 3/3