* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download File Type pdf Y 3030 quick Y
Fault tolerance wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Electrification wikipedia , lookup
Current source wikipedia , lookup
History of electric power transmission wikipedia , lookup
Stray voltage wikipedia , lookup
Power engineering wikipedia , lookup
Voltage regulator wikipedia , lookup
Shockley–Queisser limit wikipedia , lookup
Voltage optimisation wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Alternating current wikipedia , lookup
Power electronics wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Three-phase electric power wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Mains electricity wikipedia , lookup
HI 3030 System troubleshooting Quick Reference Y The 3000-product line is a software platform based system. By changing the software and keypad, the unit is capable of a new task and application. The HI 3030 weight controller keypad has tare and zero buttons. A HI 3010 filler dispenser keypad will have start and stop buttons. The HI 3030 can have four scale systems installed and use Integrated Technician. The same card A/D in a HI 3010 will control a single scale with individual load cell plugged into the back and use smart diagnostics. Using the up and down arrows, position the cursor next to the scale channel you wish to configure or diagnose. • • • • • Weight Controller >1 2 3 4 0000.00 0000.00 0000.00 0000.00 lb net kg gross oz gross g net Setup 1 2 3 • Units 4 5 6 • Test 7 8 9 0 C User * Zero Help Tare Enter Display • Print Exit • Configuration, Calibration Set points Communications Mapping. Selects, LB, KG, grams, or ounces. Converts all parameters and calibration to conform to the newly selected units. Diagnostics, Integrated Technician, relays and input verification. Configuration parameters, data list and software revision information. Capability to assign password and security levels and the factory default high level password is 0 (zero) What do you check first? • Is the Display active and keypad functional? • Does the weight change and increase as weight is applied? Monitor the front display screen to verify and simply apply weight to the scale o Does it return to the original weight reading or drift about and then return to zero? o Is the weight correct; is the weight stable to 1:10,000? o For Strain Gauge sensors, verify the signal output is in range, 0.0 to 15 mvdc. o For LVDT sensors, verify the signal output is in range, +/- 600 mvdc. • Is the wiring correct? a. Load cell b. Intermediate connection in the summing junction box. c. Cable runs routed away from high voltage. d. Shields terminated all the way back to a single ground drain. 9440 Carroll Park Dr. · Suite 150 · San Diego, CA 92121-5201· 858/278-2900 · 800/821-5831 Fax 858/278-6700 · Web www.hardysolutions.com · [email protected] Is the load cell installed correctly? Monitor load cell for valid signal voltages. Is the piping and flexures correctly installed? Apply a test weight to a load point and verify you are seeing the correct weight. Move the test weight to the next load point and verify the correct weight. Differences of more than 2.5% indicate a problem. Option slot 1 Depending on the Model and hardware configuration channel 1-4 can be; a single scale with channels 1-4 four individual load cells (Junction Box), up to four individual load cells or up to four individual scales (LC, 2S, 4S). ControlNet, RIO, Profibus, Analog Option slot 0 +Exc LINK T/R Ethernet Printer Channel 1 +Exc Shield -C2 +C2 -Exc -Sen -Sig +Sig +Sen Channel 4 Channel 3 VCANShield CAN+ V+ Channel 2 +Exc Shield -C2 +C2 -Exc -Sen -Sig +Sig +Sen +Exc Shield -C2 +C2 -Exc -Sen -Sig +Sig +Sen +C2 = Gray, -C2 = Violet, Voltage 4.9vdc Excitation Voltage = 5vdc Signal Voltage range is –0.1 to 15.3mvdc or +/- 600mvdc for LVDT’s Sense Lines installed to the junction box or jumpers. Shields landed to make this the single ground point GND Iso GND Rxd Txd V+ DeviceNet SMM 3 4 1 2 3 4 5 Com AC Outputs 110/240vac or 24vdc solid-state relays, 5amp max load, as ordered. Source provided by others. Hot in one side and out the other when activated Line 2 Neutral 1 Power-on Serial printer port, not bi-directional Diagnostics • Shield -C2 +C2 -Exc -Sen -Sig +Sig +Sen • • • • Inputs Dry contact closure between the INPUT and the COM only. DO NOT APPLY POWER TO THESE INPUT CONNECTIONS. 110/240 VAC Verify Neutral to GND is less than 1vac. Verify Hot to Neutral and Hot to GND are equal. Unit requires computer clean power. 9440 Carroll Park Dr. · Suite 150 · San Diego, CA 92121-5201· 858/278-2900 · 800/821-5831 Fax 858/278-6700 · Web www.hardysolutions.com · [email protected] Input 24VDC to power the unit and DeviceNet power