Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Post Deflection Acceleration - Baher Abu-Sbaa’ - Mohammed Naser Post Deflection Acceleration: For maximum brightness, the electrons should be accelerated to its greatest velocity. However, if the electron velocity is very high when passing through the deflection plates, the deflecting voltages will have a reduced influence and the deflection sensitivity will be poor. It is for this reason that the post deflection acceleration is provided; that is the electrons are accelerated again after they pass between the deflecting plates. We have two ways to do this : - Mesh scan expansion - Meshless scan expansion Use of expansion mesh A metallic mesh is balanced in the electron beam, and acts as a magnifying lens that causes the deflection to be further increased, which improves the deflection sensitivity. With this technique, deflection sensitivity can remain on the order of 5 to 50 V/cm even though the total electron beam acceleration is more than 10,000 V. Disadvantages ! The mesh tends to defocus the electron beam and make the spot broader than it would be without the mesh interfering with the beam. Second, the mesh conducts some of the electron beam away from the screen. This results in a reduced beam current and thus reduced spot intensity. The problem is not unique to the mesh, is that the electron beam tends to be defocused in the vicinity of the deflection plates owing to repulsion from charge distributions within the tube. Meshless scan expansion Several recent advances in cathode ray tube design have eliminated the mesh and alleviated these problems, thus producing a highperformance electron gun for use in high-frequency cathode ray tubes. The electron beam is generated from a conventional heated cathode surrounded by the control grid. The accelerating anode and two focus electrodes follow and provide focus, as well as the first accelerating voltage. These focus electrodes different from the cylindrical elements used in the conventional tube in that they are constructed from individual metal wafers with non-cylindrical holes in the center. This allows for a different focusing characteristic in the horizontal plane and the vertical plane, typically divergent in one plane being convergent in the other. The holes in the center of the metal wafers can be formed with greater precision than in a formed cylinder, and thus greater tolerances can be achieved at a lower cost. After the two focusing electrodes, the beam passes through the vertical deflection plates. The beam at this point is not fully focused, which decreases the amount of beam distortion due to the internal charge distributions. The beam will be further focused after deflection to provide: a fine spot. After vertical deflection, the beam passes through a scan expansion lens that increases the amount of beam bending in the vertical plane. The beam is then deflected in the horizontal direction and passed through another electron lens, which provides additional focusing. The beam is accelerated to the final velocity by a quadrupole lens, which provides not only an increase in electron velocity, but adds to the scan angle (scan expansion, which is similar to the mesh ) without distorting or defocusing the electron beam. The result of this design is increased deflection sensitivity, typically 2.3 V/cm for the vertical deflection and 3.7 V/cm in the horizontal direction. The difference between the vertical and horizontal deflection sensitivities is due to the fact that the vertical deflection occurs at a lower beam velocity. Because the horizontal deflection of the oscilloscope involves only a time linear sweep, while the vertical deflection requires complex waveforms, the more sensitive deflection should be reserved for the vertical direction. Using the mesh-less electron gun, 100-MHz plus oscilloscopes can be constructed with integrated circuits using only 40 or 50 V or even less for deflection. The mesh-less tube is being considerably shorter, results in smaller and lighter oscilloscopes for laboratory and portable use