Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Proposed Modification to the Florida Building Code Modification #: Name: Address: E-mail: Phone: Fax: Code: Section #: Section 553.73, Fla Stat Mark A. Zehnal 140 West Flagler Street, Suite 1603, Miami, Florida 33130 [email protected] 305-375-4632 305-375-2908 2004 FRC 4402.7.8.10 Text of Modification [additions underlined; deletions stricken]: R4402.7.8.10 Mortar or adhesive set tiles applied at an incline from 4½ 6:12 up to and including 7:12 shall have the first course of tile (this applies to pan only on two-piece barrel tile) mechanically fastened with not less than one fastener per tile. As an alternate, the first course of tile shall be applied in mortar over a single layer of minimum 20 gauge galvanized wire mesh with openings of not less than ½ inch (12.7 mm) or greater than 1½ inches (38 mm) with minimum exposure of 12 inches (305 mm) which is mechanically attached to the deck through the underlayment with approved fasteners and tin-cap when back nailing the cap sheet. Additionally, for roof inclines of 6:12 up to and including 7:12, every third tile of every fifth course, shall be mechanically fastened with not less than one fastener per tile. For roof inclines above 7:12, in addition to the mortar or adhesive, all tiles shall be mechanically fastened with not less than one fastener per tile. Apply approved flashing cement to seal all tile fastener penetrations, for all roof inclines. Fiscal Impact Statement [Provide documentation of the costs and benefits of the proposed modifications to the code for each of the following entities. Cost data should be accompanied by a list of assumptions and supporting documentation. Explain expected benefits.]: A. Impact to local entity relative to enforcement of code: This Code Modification will bring the language of FRC R4402.7.8.10 into compliance with the language and intent of FBC 1518.8.10 and RAS 120 Note #12. B. Impact to building and property owners relative to cost of compliance with code: This should reduce the adhesive/mortar set roof tile installation cost for Roofing Contractors consequentially reducing the overall cost to building owners with roof slopes less than 6/12. C. Impact to industry relative to cost of compliance with code: Should reduce adhesive/mortar set roof tile labor cost for roofs less than 6/12. Official Form 9B-3.047-2004 478184741 Rationale [Provide an explanation of why you would like this Proposed Modification to the Florida Building Code.]: This Code Modification will allow the language of FRC R4402.7.8.10 to conform to the language and intent of FBC 1518.8.10 and RAS 120 Note #12 bringing uniformity to the Code. Please explain how the proposed modification meets the following requirements: 1. Has a reasonable and substantial connection with the health, safety, and welfare of the general public: No Change 2. Strengthens or improves the code, and provides equivalent or better products, methods, or systems of construction: Brings uniformity 3. Does not discriminate against materials, products, methods, or systems of construction of demonstrated capabilities: No Change 4. Does not degrade the effectiveness of the code: Correct Section for DCA Only Committee Action: Committee Reason: Commission Action: Commission Reason: Official Form 9B-3.047-2004 478184741