OILTAP® R Technical Data (TD 115/02)
... 1) The maximum rated step voltage may be exceeded by 10% due to overexcitation of the transformer if the step capacity is limited to its rated value. 2) Higher step capacities available as special design 3) Forced current division by two parallel winding branches required 4) Applies to tap selector ...
... 1) The maximum rated step voltage may be exceeded by 10% due to overexcitation of the transformer if the step capacity is limited to its rated value. 2) Higher step capacities available as special design 3) Forced current division by two parallel winding branches required 4) Applies to tap selector ...
Breakers, Relays, and Disconnects
... An overcurrent relay can also be set to monitor current and allow a specific value of current to exist for a specified amount of time before tripping. These are called time delay relays (also known as a 51). They can be set for either a short or long time delay depending on its application. Power pl ...
... An overcurrent relay can also be set to monitor current and allow a specific value of current to exist for a specified amount of time before tripping. These are called time delay relays (also known as a 51). They can be set for either a short or long time delay depending on its application. Power pl ...
User Manual S811+ Soft Starter Effective November 2012 Supersedes July 2012
... CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict ...
... CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict ...
SABS STANDARDS DIVISION Amendment No. 8
... building. For example, the occupants might be engaged in wet processes or in the handling of flammable or explosive materials. These activities will influence the design of the installation. If a client wants more safety features for the installation than those prescribed in this part of SANS 10142, ...
... building. For example, the occupants might be engaged in wet processes or in the handling of flammable or explosive materials. These activities will influence the design of the installation. If a client wants more safety features for the installation than those prescribed in this part of SANS 10142, ...
AS/ACIF S009:2006 - Communications Alliance
... The objective of this Standard is to set out minimal requirements that may ensure the safety and integrity of a cabling installation and of the telecommunications network to which it is, or will be, connected, and to provide additional guidance for compliance with these requirements. The objective o ...
... The objective of this Standard is to set out minimal requirements that may ensure the safety and integrity of a cabling installation and of the telecommunications network to which it is, or will be, connected, and to provide additional guidance for compliance with these requirements. The objective o ...
SIMODRIVE 611 Drive Converter
... Hazardous axis motion can occur when working with the equipment. Further, all of the valid national, regional and plant/system–specific regulations must be adhered to. ...
... Hazardous axis motion can occur when working with the equipment. Further, all of the valid national, regional and plant/system–specific regulations must be adhered to. ...
Option Board I
... IO-5 temperature rating increased to -40...+85 °C DO-1, DO-2 and TEL-REL_00x installation instructions updated IO-2, IO-3 and IO-4 specifications updated (for Digital Outputs) Dual Isolated Serial Option Board introduced Information about environmental standards compliance added Power consumption fo ...
... IO-5 temperature rating increased to -40...+85 °C DO-1, DO-2 and TEL-REL_00x installation instructions updated IO-2, IO-3 and IO-4 specifications updated (for Digital Outputs) Dual Isolated Serial Option Board introduced Information about environmental standards compliance added Power consumption fo ...
Interconnection Agreement
... under the process described in this Sections 2.0 through 2.2, and must meet the technical requirements and operate as outlined in Section 3.0 and in IEEE 1547. In order to meet these requirements, modifications to the Cooperative’s EPS may be necessary as determined by the study. After applying for ...
... under the process described in this Sections 2.0 through 2.2, and must meet the technical requirements and operate as outlined in Section 3.0 and in IEEE 1547. In order to meet these requirements, modifications to the Cooperative’s EPS may be necessary as determined by the study. After applying for ...
Applications for SIPROTEC Protection Relays
... In order to make use of the instantaneous highcurrent tripping, the function must have been enabled in the relay scope configuration. The value of the short-circuit current which leads to pickup of the instantaneous tripping function is set as ‘I>>>’ value (parameter 2404). The value must be high en ...
... In order to make use of the instantaneous highcurrent tripping, the function must have been enabled in the relay scope configuration. The value of the short-circuit current which leads to pickup of the instantaneous tripping function is set as ‘I>>>’ value (parameter 2404). The value must be high en ...
MAX6342–MAX6345 6-Pin µP Reset Circuit with Power-Fail Comparator General Description
... 0.5V above the actual reset threshold and ending below it by the magnitude indicated (reset comparator overdrive). The graph indicates the maximum pulse width a negative-going VCC transient can have without causing a reset pulse. As the magnitude of the transient increases (goes further below the re ...
... 0.5V above the actual reset threshold and ending below it by the magnitude indicated (reset comparator overdrive). The graph indicates the maximum pulse width a negative-going VCC transient can have without causing a reset pulse. As the magnitude of the transient increases (goes further below the re ...
GENERATOR PROTECTION
... Beckwith Electric. He provides Customer and Industry linkage to Beckwith Electric’s solutions, as well as contributing expertise for n application engineering, training and product development. Before joining Beckwith Electric, Wayne performed in application, sales and marketing management capacitie ...
... Beckwith Electric. He provides Customer and Industry linkage to Beckwith Electric’s solutions, as well as contributing expertise for n application engineering, training and product development. Before joining Beckwith Electric, Wayne performed in application, sales and marketing management capacitie ...
DMMS 300+/350/425 - Electro Industries
... Voltages between the phases vary depending on loading factors and the quality of distribution transformers. The three-phase system is distributed in different voltage levels: 208V AC, 480V AC, 2400V AC, 4160V AC, 6900V AC, 13800V AC, and so on. Power measurement in a poly phase system is governed b ...
... Voltages between the phases vary depending on loading factors and the quality of distribution transformers. The three-phase system is distributed in different voltage levels: 208V AC, 480V AC, 2400V AC, 4160V AC, 6900V AC, 13800V AC, and so on. Power measurement in a poly phase system is governed b ...
Switchgear selection and application guide
... the complete equipment is designed by Siemens and is manufactured and tested in a single Siemens facility. The vacuum circuit breakers are checked in the switchgear cells as part of production testing. The vacuum circuit breakers are shipped in the switchgear to assure interchangeability and to redu ...
... the complete equipment is designed by Siemens and is manufactured and tested in a single Siemens facility. The vacuum circuit breakers are checked in the switchgear cells as part of production testing. The vacuum circuit breakers are shipped in the switchgear to assure interchangeability and to redu ...
MAX3397E Dual Bidirectional Low-Level Translator in µDFN General Description
... enters shutdown mode. In this mode, I/O VL can still be driven without damage to the device; however, data does not translate from I/O VL to I/O VCC. If VCC falls more than 0.8V (typ) below VL, the device disconnects the pullup resistors at I/O VL and I/O VCC. To achieve the lowest possible supply c ...
... enters shutdown mode. In this mode, I/O VL can still be driven without damage to the device; however, data does not translate from I/O VL to I/O VCC. If VCC falls more than 0.8V (typ) below VL, the device disconnects the pullup resistors at I/O VL and I/O VCC. To achieve the lowest possible supply c ...
Short-Circuit Current Rating (Calculations and Marking) 2008 SPD
... 1. On the transformer secondary, verify the SCCR of each component and the interrupting ratings of all overcurrent protective devices. 2. Identify the lowest component SCCR or overcurrent protective device interrupting rating. 3. If the lowest component SCCR or overcurrent protective device interrup ...
... 1. On the transformer secondary, verify the SCCR of each component and the interrupting ratings of all overcurrent protective devices. 2. Identify the lowest component SCCR or overcurrent protective device interrupting rating. 3. If the lowest component SCCR or overcurrent protective device interrup ...
FR-F800 Installation Guidelines
... While power is on or when the inverter is running, do not open the front cover. Otherwise you may get an electric shock. Do not run the inverter with the front cover removed. Otherwise, you may access the exposed high-voltage terminals or the charging part of the circuitry and get an electric sh ...
... While power is on or when the inverter is running, do not open the front cover. Otherwise you may get an electric shock. Do not run the inverter with the front cover removed. Otherwise, you may access the exposed high-voltage terminals or the charging part of the circuitry and get an electric sh ...
LTM4601/LTM4601-1 - 12A DC/DC uModules with PLL, Output Tracking and Margining
... The LTM®4601 is a complete 12A step-down switch mode DC/DC power supply with onboard switching controller, MOSFETs, inductor and all support components. The µModule® regulator is housed in small surface mount 15mm × 15mm × 2.82mm LGA and 15mm × 15mm × 3.42mm BGA packages. Operating over an input vol ...
... The LTM®4601 is a complete 12A step-down switch mode DC/DC power supply with onboard switching controller, MOSFETs, inductor and all support components. The µModule® regulator is housed in small surface mount 15mm × 15mm × 2.82mm LGA and 15mm × 15mm × 3.42mm BGA packages. Operating over an input vol ...
Kein Folientitel
... Electrographite is the material with the widest field of application and therefore the most widely used material for carbon brushes. Electrographite is used, within certain limits, both on commutators and on slip-rings. Because of its high purity, electrographite protects the material on which it ru ...
... Electrographite is the material with the widest field of application and therefore the most widely used material for carbon brushes. Electrographite is used, within certain limits, both on commutators and on slip-rings. Because of its high purity, electrographite protects the material on which it ru ...
History of electric power transmission
The history of the technology of moving electricity far from where it was generated dates from the late 19th century. This includes movement of electricity in bulk (formally referred to as ""transmission""), and the delivery of electricity (""distribution"") to individual customers. The distinction between the two terms did not exist in early years and were used interchangeably.