
Aalborg Universitet
... numerical MATLAB solving of circuit equations and PSCAD/EMTDC model show corresponding results. The main advantage of this result is that the shunt reactor model has been implemented correctly in PSCAD/EMTDC and therefore can be used together with a complete model of the total system including PSCAD ...
... numerical MATLAB solving of circuit equations and PSCAD/EMTDC model show corresponding results. The main advantage of this result is that the shunt reactor model has been implemented correctly in PSCAD/EMTDC and therefore can be used together with a complete model of the total system including PSCAD ...
Aalborg Universitet EHV/HV Underground Cable Systems for Power Transmission Bak, Claus Leth
... transformers and cables, fault clearing, load shedding and system islanding to result in long‐duration TOV’s. Such TOV’s must be well‐known in order for us to be able to design surge arrester energy absorption capability. ...
... transformers and cables, fault clearing, load shedding and system islanding to result in long‐duration TOV’s. Such TOV’s must be well‐known in order for us to be able to design surge arrester energy absorption capability. ...
HELICALLY FORMED FITTINGS
... Optical Fibre Composite Overhead Ground Wire combines both the functions of grounding and communications. ...
... Optical Fibre Composite Overhead Ground Wire combines both the functions of grounding and communications. ...
XR-i IGNITION
... removal of original points plate assembly. Refer to Figure 5 to perform the following steps: 1. Remove the e-clip holding the vacuum linkage arm to the points plate with a small screwdriver. 2. Remove the 2 screws and the vacuum mechanism from the distributor body and set aside. 3. Carefully remo ...
... removal of original points plate assembly. Refer to Figure 5 to perform the following steps: 1. Remove the e-clip holding the vacuum linkage arm to the points plate with a small screwdriver. 2. Remove the 2 screws and the vacuum mechanism from the distributor body and set aside. 3. Carefully remo ...
Instructions for use and maintenance
... Standard fixed coils are used for heating and releasing nuts, couplings, gaskets, hinges, exhaust pipes, bolts, etc. that are accessible so that coils can be pushed on them. The lifetime of coils can be increased by cleaning the heated material from rust, paint, grease, etc. During the heating proce ...
... Standard fixed coils are used for heating and releasing nuts, couplings, gaskets, hinges, exhaust pipes, bolts, etc. that are accessible so that coils can be pushed on them. The lifetime of coils can be increased by cleaning the heated material from rust, paint, grease, etc. During the heating proce ...
Ironless vacuum linear motor series
... Tecnotion is the global authority on direct drive motor technology. We are the world’s only unbundled manufacturer of linear and torque motors. A former part of Philips, we specialize solely in the development and production of linear and torque motors. Because of this, our expertise, customer servi ...
... Tecnotion is the global authority on direct drive motor technology. We are the world’s only unbundled manufacturer of linear and torque motors. A former part of Philips, we specialize solely in the development and production of linear and torque motors. Because of this, our expertise, customer servi ...
Chapter18 - Free-Energy
... induced in the coil L2. It makes no difference if the coils are air-core or if they have an iron core. In other words, it can be assumed that the coils are suspended isolated in air. This is a well-known fact but it is considered to be of little interest as it is thought to be a trivial matter – it ...
... induced in the coil L2. It makes no difference if the coils are air-core or if they have an iron core. In other words, it can be assumed that the coils are suspended isolated in air. This is a well-known fact but it is considered to be of little interest as it is thought to be a trivial matter – it ...
Control Circuit Transients - GE Grid Solutions Online Store
... inductance (flux linkages) and capacitance between the two systems. In any given installation all modes of coupling are present to various degrees. Switchyard designers are becoming increasingly aware of the need to minimize external coupling by proper routing of cables, shielding, and attention to ...
... inductance (flux linkages) and capacitance between the two systems. In any given installation all modes of coupling are present to various degrees. Switchyard designers are becoming increasingly aware of the need to minimize external coupling by proper routing of cables, shielding, and attention to ...
ignitions
... The M&W CDI ignition systems are designed to operate directly from 13.8V. Although the 115mJ Pro series will tolerate small voltage fluctuations it is vitally important that the 250mJ and larger Pro-Drag ignitions have a stable supply which does not drop below 12.5V. Do not use a power supply above ...
... The M&W CDI ignition systems are designed to operate directly from 13.8V. Although the 115mJ Pro series will tolerate small voltage fluctuations it is vitally important that the 250mJ and larger Pro-Drag ignitions have a stable supply which does not drop below 12.5V. Do not use a power supply above ...
Transmission_Media_and_Codes
... • They require that electrical signals must be converted first to light and converted back at the other end • Must be handled with great care; some of these fibers could be a thin as human hair ...
... • They require that electrical signals must be converted first to light and converted back at the other end • Must be handled with great care; some of these fibers could be a thin as human hair ...
Installation and Troubleshooting Guide
... HIGH SPEED MISS-FIRE OR WEAK HOLE SHOT: 1. Check the DVA voltage from Idle to WOT. If the voltage drops sharply right when the miss starts, there could be a problem in the charge coil. Check resistance and do a visual inspection of the charge coil. If it is discolored or has what appears to be water ...
... HIGH SPEED MISS-FIRE OR WEAK HOLE SHOT: 1. Check the DVA voltage from Idle to WOT. If the voltage drops sharply right when the miss starts, there could be a problem in the charge coil. Check resistance and do a visual inspection of the charge coil. If it is discolored or has what appears to be water ...
Aalborg Universitet after disconnection
... phases. Fig 16 shows the voltage waveform were the mutual inductance is multiplied with 100 and made equal for all phases while the self inductance of one phase is reduced by 3,5% and increased with 3,5% on an other phase. Here overvoltage occurs and modulation appears in the waveform as expected. T ...
... phases. Fig 16 shows the voltage waveform were the mutual inductance is multiplied with 100 and made equal for all phases while the self inductance of one phase is reduced by 3,5% and increased with 3,5% on an other phase. Here overvoltage occurs and modulation appears in the waveform as expected. T ...
Did Tesla`s Wardenclyffe tower generate squarewaves?
... excite the Earth Resonances. If your VLF transmitter managed to hit the target frequency, your success would only be temporary, since the Earth system would slowly change, and you'd lose the resonance. The solution is found above: stop treating the Earth as a target frequency for your drive transmit ...
... excite the Earth Resonances. If your VLF transmitter managed to hit the target frequency, your success would only be temporary, since the Earth system would slowly change, and you'd lose the resonance. The solution is found above: stop treating the Earth as a target frequency for your drive transmit ...
Circuit analysis of magnetic couplings between circular turn and
... turn and the k-th spiral coil turn. Numerical results were compared with the results obtained during from the measurements. Calculations were carried out for the forcing turn Rw = 0.055 m and the distance between the forcing turn and plate turns z = [0.0087, 0.0112] m. Leading non-sinusoidal voltage ...
... turn and the k-th spiral coil turn. Numerical results were compared with the results obtained during from the measurements. Calculations were carried out for the forcing turn Rw = 0.055 m and the distance between the forcing turn and plate turns z = [0.0087, 0.0112] m. Leading non-sinusoidal voltage ...
armature - Study Channel
... • In the next quarter, from 90-180 degree, flux linking the coil gradually increases, but the rate of change of flux linkage decreases. Hence, induced EMF decreases till position 5. Here the EMF induced is zero. The current flows from A to B and C to D. Flow of current is from ABMLCD. In load resist ...
... • In the next quarter, from 90-180 degree, flux linking the coil gradually increases, but the rate of change of flux linkage decreases. Hence, induced EMF decreases till position 5. Here the EMF induced is zero. The current flows from A to B and C to D. Flow of current is from ABMLCD. In load resist ...
Coupling Factor Calculation of Low Frequency RFID Systems by the
... The inductor shall be placed in a changing (periodically in magnitude) uniform magnetic field. The magnetic flux that flows through the component will induce certain voltage. The ratio of the induced voltage across the coil and the magnitude of the changing magnetic field that induces the voltage is ...
... The inductor shall be placed in a changing (periodically in magnitude) uniform magnetic field. The magnetic flux that flows through the component will induce certain voltage. The ratio of the induced voltage across the coil and the magnitude of the changing magnetic field that induces the voltage is ...
inductance
... •Most materials have negligible magnetic properties •A few materials, like iron are ferromagnetic •They can enhance inductance enormously •Many inductors (and similar devices, like transformers) have iron cores •We will ignore this Symbol for iron core inductor: •We won’t make this distinction ...
... •Most materials have negligible magnetic properties •A few materials, like iron are ferromagnetic •They can enhance inductance enormously •Many inductors (and similar devices, like transformers) have iron cores •We will ignore this Symbol for iron core inductor: •We won’t make this distinction ...
Overview - Ocean Networks Canada
... an aluminum anode is used in order to offer high anti-corrosion effect, where the effect is maintained as long as 5 years. To regularly monitor the anti-corrosion effect, the potential between Reference Electrode and the metals is measured. In addition, degree of wear of the anode is monitored with ...
... an aluminum anode is used in order to offer high anti-corrosion effect, where the effect is maintained as long as 5 years. To regularly monitor the anti-corrosion effect, the potential between Reference Electrode and the metals is measured. In addition, degree of wear of the anode is monitored with ...
RFID Coil Design
... application utilizing the VLF (100 kHz – 500 kHz) band, the wavelength of the operating frequency is a few kilometers (λ = 2.4 Km for 125 kHz signal). Because of its long wavelength, a true antenna can never be formed in a limited space of the device. Alternatively, a small loop antenna coil that is ...
... application utilizing the VLF (100 kHz – 500 kHz) band, the wavelength of the operating frequency is a few kilometers (λ = 2.4 Km for 125 kHz signal). Because of its long wavelength, a true antenna can never be formed in a limited space of the device. Alternatively, a small loop antenna coil that is ...
Loading coil

A loading coil or load coil is an inductor that is inserted into an electronic circuit to increase its inductance. A loading coil is not a transformer to provide coupling to another other circuit. The term originated in the 19th century for inductors used to prevent signal distortion in long-distance telegraph transmission cables. The term is also used for inductors in radio antennas, or between the antenna and its feedline, to make an electrically short antenna resonant at its operating frequency.Loading coils are historically also known as Pupin coils after Mihajlo Pupin, especially when used for the Heaviside condition and the process of inserting them is sometimes called pupinization.The concept of loading coils was discovered by Oliver Heaviside in studying the problem of slow signalling speed of the first transatlantic telegraph cable in the 1860s. He concluded additional inductance was required to prevent amplitude and time delay distortion of the transmitted signal. The mathematical condition for distortion-free transmission is known as the Heaviside condition. Previous telegraph lines were overland or shorter and hence had less delay, and the need for extra inductance was not as great. Submarine communications cables are particularly subject to the problem, but early 20th century installations using balanced pairs were often continuously loaded with iron wire or tape rather than discretely with loading coils, which avoided the sealing problem.