• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
FPO SHC5320 FEATURES DESCRIPTION
FPO SHC5320 FEATURES DESCRIPTION

... During the adjustment, the sample/hold should be switching continuously between the Sample and the Hold modes. The offset should then be adjusted to zero output for the periods when the amplifier is in the Hold mode. In this way, the effects of both amplifier offset and charge offset will be account ...
Chapter 2 - Basic Op-Amp Circuits
Chapter 2 - Basic Op-Amp Circuits

... The output swing of a zero-crossing detector may be too large in some applications. In some applications, necessary to limit the output voltage levels of comparator to a value less than provided by the saturated op-amp. We can bound the output by using a zener diode – limit the output voltage to the ...
A SLOTTED LECHER LINE FOR lMPEDANCE - Research
A SLOTTED LECHER LINE FOR lMPEDANCE - Research

... speaking such inserted devices are open to the following objections: either they have a very narrow frequency band and must accordingly be matched with the utmost accuracy to each test frequency (e.g. half-wave stubs), or they have a broad frequency band but at the same time such complex> four-pole ...
DRN3.1-Pulse/Analog/Floating Point to Proportional Resistance
DRN3.1-Pulse/Analog/Floating Point to Proportional Resistance

... digital input, and analog output circuits should not be earth grounded at two points. Any field device connected to this transformer must use the same common. If you are not sure of other field device configuration, use separate transformers for isolation. If the 24 volt AC power is shared with othe ...
LabSU2005_8
LabSU2005_8

... by VCC and the R1 and R2 voltage divider. The DC Operating point of this circuit is stable for two primary reasons:  The base voltage is determined primarily by the voltage divider R1 and R2 and is effectively independent of the transistor parameters (especially f).  The emitter resistor RE stabi ...
ÿþw w w . d a t a s h e e t 4 u . c o m
ÿþw w w . d a t a s h e e t 4 u . c o m

... The ALC650 has a 20-bit stereo DAC and 18-bit stereo ADC, full duplex AC'97 2.2 compatible audio CODEC designed for PC multimedia systems, including host/soft audio and AMR/CNR based designs. The ALC650 incorporates proprietary converter technology to achieve a high SNR, greater than 90 dB. The ALC6 ...
BB ADS831 datasheet
BB ADS831 datasheet

... output of the op amp and the input of the ADS831 will be beneficial in almost all interface configurations. This will de-couple the op amp’s output from the capacitive load and avoid gain peaking, which can result in increased noise. For best spurious and distortion performance, the resistor value s ...
Measurement and Error - Gopalan College of Engineering
Measurement and Error - Gopalan College of Engineering

... For example, the accuracy of an instrument having full scale reading of 50 units may be expressed as ± 0.1% of full scale reading. From this accuracy indication, practically accuracy is expressed in terms of limits of error. So for the accuracy limits specified above, there will be ± 0.05 units erro ...
test 2 review questi..
test 2 review questi..

... A. By displaying a large number of cycles, the FFT math function will give a good approximation of the Fourier series for the displayed signal. B. In order to get a good approximation of the Fourier series, it will be necessary to decrease the horizontal scale until no more than 3 cycles of the sign ...
Product Specifications VC-6000 Monitoring System Monitoring Module – SM-610-A04
Product Specifications VC-6000 Monitoring System Monitoring Module – SM-610-A04

... (ISO or variable HP and LP), up to 4x Axial Position, 1x dual channel Relative Expansion, 4x Vector, 2x Speed, 1x Eccentricity. 3 Binary inputs and 6x DC Outputs and 10x Relays. The VC-6000 Monitoring System hardware is used for both - stand-alone safety monitoring and condition monitoring using the ...
LDO PSRR Measurement Simplified
LDO PSRR Measurement Simplified

... method is tested and verified using TPS72715 LDO and THS3120 high-speed amplifier from Texas Instruments. The basic set-up is shown in Figure 3. The PSRR is measured with a no-load condition and the resulting measured PSRR graph corresponds with the datasheet graph of PSRR. Keep in mind the followin ...
PMMC
PMMC

... coil of fine wire is suspended in a magnetic field produced by permanent magnet. According to the fundamental law of electromagnetic force, the coil will rotate in the magnetic field when it carries an electric current by electromagnetic (EM) torque effect. A pointer which attached the movable coil ...
MAX1003 Low-Power, 90Msps, Dual 6-Bit ADC _______________General Description ____________________________Features
MAX1003 Low-Power, 90Msps, Dual 6-Bit ADC _______________General Description ____________________________Features

... 250mVp-p, or 500mVp-p. With an AC-coupled input signal, matching performance between input channels is typically better than 0.1dB gain, 1/4LSB offset, and 0.5° phase. Dynamic performance is 5.85 effective number of bits (ENOB) with a 20MHz analog input signal, or 5.7 ENOB with a 50MHz signal. The M ...
TS4100,01,02 EVB User Guide
TS4100,01,02 EVB User Guide

... 5. To monitor the COM-A or COM-B output signal, connect the positive terminal of the digital voltmeter to the test point labeled COMA or COM-B and the negative terminal to the adjacent test point labeled GND. 6. Turn on the power supply and check that the digital voltmeter is reading an output volta ...
Amplifiers_p108..
Amplifiers_p108..

... The amplitude of the voltage difference across the small resistor, R1, is V1 = V*R1/(R1+R2), where V is the voltage amplitude from the function generator. Since R1=10 Ohm here and R2 is 10 kOhm, the amplitude V1 is about 1000 times smaller than V (which is less than 20 Volts peak-to-peak). The compl ...
User`s Guide MultiPro™ Digital MultiMeter Series With PC Interface
User`s Guide MultiPro™ Digital MultiMeter Series With PC Interface

... will not interfere with the resistance reading. 5. For Resistance tests, read the resistance on the display. 6. For Continuity tests, If the resistance is < 20Ω, an audible tone will sound Automatic test lead resistance calibration When manually entering the 50Ω range (using the RANGE key) the autom ...
Dual Channel Function/Arbitrary Waveform Generators
Dual Channel Function/Arbitrary Waveform Generators

... The 4050B Series Dual Channel Function/ Arbitrary Waveform Generators are capable of generating stable and precise sine, square, triangle, pulse, and arbitrary waveforms. With an easy-to-read color display and intuitive user interface with numeric keypad, these instruments offer plenty of features i ...
7 Segment Display Driver
7 Segment Display Driver

... The 4Bit input will be created using a 4 pin DIP switch to supply +5V or 0V to represent logic 1 and 0 respectively. The switch will be implemented in one of two configurations to prevent a floating voltage on the input pins which would corrupt our output. ...
Evaluates:  MAX13042E MAX13042E Evaluation Kit General Description Features
Evaluates: MAX13042E MAX13042E Evaluation Kit General Description Features

... matched length (within 5 mils) to maintain propagationtime uniformity. The EV kit dedicates two channels for translation between VL to VCC and two channels for translation between VCC to VL. Input signals can either be applied using SMA connectors IVL1, IVL2, IVCC3, and IVCC4 or at test points TP1–T ...
IX Gamma-Gamma Angular Correlation
IX Gamma-Gamma Angular Correlation

... this case the energy of the transition is higher and a -ray with energy in the MeV range is emitted rather than a visible photon with energy in the eV range. Often when two gamma rays are emitted in rapid succession from a nucleus, the directions of the emission of the two rays are correlated. Assu ...
MAX115/MAX116 2x4-Channel, Simultaneous-Sampling 12-Bit ADCs ________________General Description
MAX115/MAX116 2x4-Channel, Simultaneous-Sampling 12-Bit ADCs ________________General Description

... The T/H aperture delay is typically 10ns. The 500ps aperture-delay mismatch between the T/Hs allows the relative phase information of up to four different inputs to be preserved. Figure 3 shows the equivalent input circuit, illustrating the ADC’s sampling architecture. Only one of four T/H stages wi ...
FSTU32160 16-Bit to 32-Bit Multiplexer/Demultiplexer Bus Switch with 2V Undershoot Protection
FSTU32160 16-Bit to 32-Bit Multiplexer/Demultiplexer Bus Switch with 2V Undershoot Protection

... The device can be used in applications where two buses need to be addressed simultaneously. The FSTU32160 is designed so that the A Port demultiplexes into B1 or B2 or both. The A and B Ports have “undershoot hardened” circuit protection to support an extended range to 2.0V below ground. Fairchild’s ...
Chapter 2: Display Systems
Chapter 2: Display Systems

... Many monitors accept separate video, horizontal, and vertical signals as described previously. For broadcast television and some CRT monitors, these signals are all combined into one composite signal. As a first step, the horizontal and vertical sync signals are combined. The horizontal sync pulses ...
LM1815
LM1815

... edge of the input signal. Unlike other zero crossing detectors, the LM1815 cannot be triggered until the input signal has crossed an “arming” threshold on the positive-going portion of the waveform. The arming circuit is reset when the chip is triggered, and subsequent zero crossings are ignored unt ...
EECE 495 Lab 6: 7-Segment Display
EECE 495 Lab 6: 7-Segment Display

... order from least significant to most significant. Outputs are labeled a, b, c, d, e, f, and g, each letter corresponding to a standardized segment designation for 7-segment displays. Be sure the input signals have a corresponding 10k resister tied to ground. (see Figure 1 below). The DIP switch sho ...
< 1 ... 53 54 55 56 57 58 59 60 61 ... 97 >

Oscilloscope



An oscilloscope, previously called an oscillograph, and informally known as a scope, CRO (for cathode-ray oscilloscope), or DSO (for the more modern digital storage oscilloscope), is a type of electronic test instrument that allows observation of constantly varying signal voltages, usually as a two-dimensional plot of one or more signals as a function of time. Other signals (such as sound or vibration) can be converted to voltages and displayed.Oscilloscopes are used to observe the change of an electrical signal over time, such that voltage and time describe a shape which is continuously graphed against a calibrated scale. The observed waveform can be analyzed for such properties as amplitude, frequency, rise time, time interval, distortion and others. Modern digital instruments may calculate and display these properties directly. Originally, calculation of these values required manually measuring the waveform against the scales built into the screen of the instrument.The oscilloscope can be adjusted so that repetitive signals can be observed as a continuous shape on the screen. A storage oscilloscope allows single events to be captured by the instrument and displayed for a relatively long time, allowing observation of events too fast to be directly perceptible.Oscilloscopes are used in the sciences, medicine, engineering, and telecommunications industry. General-purpose instruments are used for maintenance of electronic equipment and laboratory work. Special-purpose oscilloscopes may be used for such purposes as analyzing an automotive ignition system or to display the waveform of the heartbeat as an electrocardiogram.Before the advent of digital electronics, oscilloscopes used cathode ray tubes (CRTs) as their display element (hence were commonly referred to as CROs) and linear amplifiers for signal processing. Storage oscilloscopes used special storage CRTs to maintain a steady display of a single brief signal. CROs were later largely superseded by digital storage oscilloscopes (DSOs) with thin panel displays, fast analog-to-digital converters and digital signal processors. DSOs without integrated displays (sometimes known as digitisers) are available at lower cost and use a general-purpose digital computer to process and display waveforms.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report