• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Integrated multistandard comb filter
Integrated multistandard comb filter

... • Delay line start control • Mode control. The signal processing is based on a 3 × fsc system clock (CL3), that is generated by the clock processing from the fsc signal at FSC (pin 1) via a PLL. Because the subcarrier frequency divided by the line frequency results not in an integer value a clock ph ...
Accurately measuring ADC driving-circuit settling time (slyt262.PDF, 197 KB)
Accurately measuring ADC driving-circuit settling time (slyt262.PDF, 197 KB)

... Many modern data acquisition systems consist of highspeed, high-resolution ADCs.1 CMOS-switched, capacitorbased ADCs are often chosen for such designs due to their low cost and low power dissipation. These ADCs use an unbuffered front end directly coupled to the sampling network. To effectively mini ...
NI USB-6001/6002/6003 User Guide
NI USB-6001/6002/6003 User Guide

... Off ...
MAX1121 1.8V, 8-Bit, 250Msps Analog-to-Digital Converter with LVDS Outputs for Wideband Applications
MAX1121 1.8V, 8-Bit, 250Msps Analog-to-Digital Converter with LVDS Outputs for Wideband Applications

... up to 250Msps while consuming only 477mW. At 250Msps and an input frequency of 100MHz, the MAX1121 achieves a spurious-free dynamic range (SFDR) of 68dBc. Its excellent signal-to-noise ratio (SNR) of 48.9dB at 10MHz remains flat (within 0.5dB) for input tones up to 500MHz. This makes the MAX1121 ide ...
ADS5421 数据资料 dataSheet 下载
ADS5421 数据资料 dataSheet 下载

... INPUT BIASING (VCM) The ADS5421 operates from a single +5V supply, and requires each of the analog inputs to be externally biased to a common-mode voltage of typically +2.5V. This allows a symmetrical signal swing while maintaining sufficient headroom to either supply rail. Communication systems are ...
AD8048
AD8048

... can be closely estimated as ωO f 3 dB ≅   R  2π 1+  F     RG   ...
AD8564 数据手册DataSheet 下载
AD8564 数据手册DataSheet 下载

... consideration in maximizing the high speed operation of the AD8564. Source resistance, in combination with equivalent input capacitance, may cause a lagged response at the input, thus delaying the output. The input capacitance of the AD8564, in combination with stray capacitance from an input pin to ...
MAX1448 10-Bit, 80Msps, Single 3.0V, Low-Power ADC with Internal Reference General Description
MAX1448 10-Bit, 80Msps, Single 3.0V, Low-Power ADC with Internal Reference General Description

... only 120mW while delivering a 59dB (typ) signal-tonoise ratio (SNR) at a 20MHz input frequency. The fully differential input stage has a -3dB 400MHz bandwidth and may be operated with single-ended inputs. In addition to low operating power, the MAX1448 features a 5µA power-down mode for idle periods ...
Draw a complete schematic in your lab book, including all ground
Draw a complete schematic in your lab book, including all ground

... bypass capacitors to filter the supply lines. A bypass capacitor between each power supply lead and ground, will provide a miniature current “reservoir” that can quickly supply current when needed. This capacitor is normally in the range 1 F – 10 F. Compact capacitors in this range are usually ele ...
3.2 The Wien Bridge Oscillator
3.2 The Wien Bridge Oscillator

... (Abstract: These configuratios increase the input resistance and the current gain; the VBE is twice the normal and the saturation voltage is at least VBE.) The common-collector - common-emitter (CC-CE), common-collector-common-collector (CCCC), and Darlington configurations are all closely related. ...
LF155/LF156/LF157 Series Monolithic JFET Input Operational Amplifiers LF155/LF156/LF157 General Description
LF155/LF156/LF157 Series Monolithic JFET Input Operational Amplifiers LF155/LF156/LF157 General Description

... consequently there is negligible effect on stability margin. However, if the feedback pole is less than approximately six times the expected 3 dB frequency a lead capacitor should be placed from the output to the input of the op amp. The value of the added capacitor should be such that the RC time c ...
AD8428 数据手册DataSheet 下载
AD8428 数据手册DataSheet 下载

... The first stage works as follows. To keep its two inputs matched, Amplifier A1 must keep the collector of Q1 at a constant voltage. It does this by forcing −RG to be a precise diode drop from −IN. Similarly, A2 forces +RG to be a constant diode drop from +IN. Therefore, a replica of the differential ...
INA111 High Speed FET-Input INSTRUMENTATION AMPLIFIER
INA111 High Speed FET-Input INSTRUMENTATION AMPLIFIER

... current return path, the inputs will float to a potential which exceeds the common-mode range of the INA111 and the input amplifiers will saturate. If the differential source resistance is low, the bias current return path can be connected to one input (see the thermocouple example in Figure 3). Wit ...
MAX187/MAX189 +5V, Low-Power, 12
MAX187/MAX189 +5V, Low-Power, 12

... is available at DOUT in unipolar serial format. A high bit, signaling the end of conversion (EOC), followed by the data bits (MSB first), make up the serial data stream. The MAX187 operates in one of two states: (1) internal reference and (2) external reference. Select internal reference operation b ...
LABORATORY WORK BOOK For The Course EL
LABORATORY WORK BOOK For The Course EL

... Department of Electronic Engineering N.E.D. University of Engineering & Technology, Karachi –75270, Pakistan ...
ADS5120 数据资料 dataSheet 下载
ADS5120 数据资料 dataSheet 下载

... digital I/O supply (DRVDD) can be set to either +1.8V or +3.3V. The ADC core of each channel consists of 10 pipeline stages. Each of the 10 stages produces one digital bit per stage. Both the rising and the falling clock edges are utilized to propagate the sample through the pipeline every half cloc ...
3.3 V, 3.2 Gbps, Limiting Amplifier ADN2891
3.3 V, 3.2 Gbps, Limiting Amplifier ADN2891

... The ADN2891 is a 3.2 Gbps limiting amplifier with integrated loss-of-signal (LOS) detection circuitry and a received signal strength indicator (RSSI). This part is optimized for SONET, Gigabit Ethernet (GbE), and Fibre Channel optoelectronic conversion applications. The ADN2891 has a differential in ...
The ZEUS MVD Clock and Control System
The ZEUS MVD Clock and Control System

... and downloads status information to the Helix chips in the detector. The VME controller can check all data and status information present on the boards by reading it back. During downloading, one 20-bit word is serially sent to each of the Helix chips. Each channel of the driver system accesses five ...
unit 1 - WordPress.com
unit 1 - WordPress.com

... For circuits where it is necessary to remove or null the offset, many op-amp chips provide two pins that enable this to be done. Using the offset null adjustment requires a potentiometer with its wiper connected to the negative supply with some op amps or to 0 V with others so it is necessary to che ...
MAX1182 Dual 10-Bit, 65Msps, 3V, Low-Power ADC General Description
MAX1182 Dual 10-Bit, 65Msps, 3V, Low-Power ADC General Description

... TQFP package, and is specified for the extended industrial (-40°C to +85°C) temperature range. Pin-compatible higher and lower speed versions of the MAX1182 are also available. Please refer to the MAX1180 datasheet for 105Msps, the MAX1181 datasheet for 80Msps, the MAX1183 datasheet for 40Msps, and ...
Instruction manual
Instruction manual

... Do not measure Frequency on high voltage (>1000V) to avoid electrical shock hazard and/or damage to the instrument. Frequency is the number of cycles a voltage or current signal completes each second. The Meter can measure Frequency or Duty Cycle while making either an AC Voltage or AC Current measu ...
APV25S0 - Calibration Circuit
APV25S0 - Calibration Circuit

... of the variable delay line is used to delay a periodic square wave (pulse), which is then compared to a reference signal (strobe). A phase detector compares the falling edge of the reference and of the delayed signal (delout), activating a charge pump for a period equal to the delay between the two ...
MAX1444 10-Bit, 40Msps, 3.0V, Low-Power ADC with Internal Reference General Description
MAX1444 10-Bit, 40Msps, 3.0V, Low-Power ADC with Internal Reference General Description

... may be operated with single-ended inputs. In addition to low operating power, the MAX1444 features a 5µA power-down mode for idle periods. An internal 2.048V precision bandgap reference is used to set the ADC full-scale range. A flexible reference structure allows the user to supply a buffered, dire ...
Ultrasound Physics Volume I
Ultrasound Physics Volume I

... slide, the basic angles between 0 and 90 degrees (inclusively) are shown, but the cosine values are also given in the table for angles greater than 90 degrees. From this table it should be evident that 45 degrees is basically the “same” angle as 135 degrees, 225 degrees, and 315 degrees (not shown), ...
AN028: Building an Auto-Ranging DMM with the ICL7103A
AN028: Building an Auto-Ranging DMM with the ICL7103A

... The designer must also consider the potential hazards of four additional sources of leakage current (3 switches plus input protection). For 10µV resolution, these leakage currents must be less than 10pA for the resistor values shown above. A major advantage to type A is its versatility. It can easil ...
< 1 ... 33 34 35 36 37 38 39 40 41 ... 97 >

Oscilloscope



An oscilloscope, previously called an oscillograph, and informally known as a scope, CRO (for cathode-ray oscilloscope), or DSO (for the more modern digital storage oscilloscope), is a type of electronic test instrument that allows observation of constantly varying signal voltages, usually as a two-dimensional plot of one or more signals as a function of time. Other signals (such as sound or vibration) can be converted to voltages and displayed.Oscilloscopes are used to observe the change of an electrical signal over time, such that voltage and time describe a shape which is continuously graphed against a calibrated scale. The observed waveform can be analyzed for such properties as amplitude, frequency, rise time, time interval, distortion and others. Modern digital instruments may calculate and display these properties directly. Originally, calculation of these values required manually measuring the waveform against the scales built into the screen of the instrument.The oscilloscope can be adjusted so that repetitive signals can be observed as a continuous shape on the screen. A storage oscilloscope allows single events to be captured by the instrument and displayed for a relatively long time, allowing observation of events too fast to be directly perceptible.Oscilloscopes are used in the sciences, medicine, engineering, and telecommunications industry. General-purpose instruments are used for maintenance of electronic equipment and laboratory work. Special-purpose oscilloscopes may be used for such purposes as analyzing an automotive ignition system or to display the waveform of the heartbeat as an electrocardiogram.Before the advent of digital electronics, oscilloscopes used cathode ray tubes (CRTs) as their display element (hence were commonly referred to as CROs) and linear amplifiers for signal processing. Storage oscilloscopes used special storage CRTs to maintain a steady display of a single brief signal. CROs were later largely superseded by digital storage oscilloscopes (DSOs) with thin panel displays, fast analog-to-digital converters and digital signal processors. DSOs without integrated displays (sometimes known as digitisers) are available at lower cost and use a general-purpose digital computer to process and display waveforms.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report