Analog Dialogue Volume 48 Number 3
... directly to the –48-V supply. Isolation also provides protection against high voltages or currents caused by the line surges or ground loops that can occur in a system with multiple grounds. The isolated power channel (3.3 V_ISO) allows the primary-side circuitry to be powered from the secondary si ...
... directly to the –48-V supply. Isolation also provides protection against high voltages or currents caused by the line surges or ground loops that can occur in a system with multiple grounds. The isolated power channel (3.3 V_ISO) allows the primary-side circuitry to be powered from the secondary si ...
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)
... Yuji Osaki, Tetsuya Hirose, Nobutaka Kuroki, Masahiro Numa, “A Low-Power Level Shifter With Logic Error Correction for Extremely Low-Voltage Digital CMOS LSIs”, IEEE Journal of Solid-State Circuits, Vol. 47, No. 7, July 2012, pp. 1776-1783. Karthikeyan.G, Mathan.K, “Design and Analysis of Low Power ...
... Yuji Osaki, Tetsuya Hirose, Nobutaka Kuroki, Masahiro Numa, “A Low-Power Level Shifter With Logic Error Correction for Extremely Low-Voltage Digital CMOS LSIs”, IEEE Journal of Solid-State Circuits, Vol. 47, No. 7, July 2012, pp. 1776-1783. Karthikeyan.G, Mathan.K, “Design and Analysis of Low Power ...
Selection of Capacitance for Compensated Self Excited Induction Generator Using Meta-Heuristic Approach
... range of different parameters as voltage, speed and excitation capacitance, within which self-excitation is possible. In [16] an analysis for the performance of SEIG based on eigenvalues is proposed. The lower and upper limits of the excitation capacitance are identified. However, this approach is a ...
... range of different parameters as voltage, speed and excitation capacitance, within which self-excitation is possible. In [16] an analysis for the performance of SEIG based on eigenvalues is proposed. The lower and upper limits of the excitation capacitance are identified. However, this approach is a ...
Instruction Manual
... determine the number of devices that may be connected to a telephone line. Excessive RENs on a telephone line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of RENs should not exceed five (5.0). To be certain of the number of devices that m ...
... determine the number of devices that may be connected to a telephone line. Excessive RENs on a telephone line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of RENs should not exceed five (5.0). To be certain of the number of devices that m ...
a new static synchronous series compensator for real power control
... increase the transmission capability of the lines and to control the power flow over designated transmission routes. In the future, what is aimed to be realized through their solid-state implementation is a teal-the control of any of the parameters characterizing a üne: transmission voltage, line im ...
... increase the transmission capability of the lines and to control the power flow over designated transmission routes. In the future, what is aimed to be realized through their solid-state implementation is a teal-the control of any of the parameters characterizing a üne: transmission voltage, line im ...
DC/DC converter
... isolated, regulated and monitored power to IGBTs and MOSFETs drivers. The Module requires an Input voltage of 12VDC + 10% and has dual outputs with 15V resp. -4V with a maximum current of 140mA. This DC/DC module has a unique diagnostic output allowing the user to monitor the converter output voltag ...
... isolated, regulated and monitored power to IGBTs and MOSFETs drivers. The Module requires an Input voltage of 12VDC + 10% and has dual outputs with 15V resp. -4V with a maximum current of 140mA. This DC/DC module has a unique diagnostic output allowing the user to monitor the converter output voltag ...
Project P917 - EURESCOM Home Page
... solutions have been proposed to power the access network equipment with DC powering over the existing telecom cables and /or local AC powering with battery backup. The drawback of these solutions is that they can either supply low power for an extended period of time (remote feeding through existing ...
... solutions have been proposed to power the access network equipment with DC powering over the existing telecom cables and /or local AC powering with battery backup. The drawback of these solutions is that they can either supply low power for an extended period of time (remote feeding through existing ...
Design and Application of a Power Unit to Use Plug
... demand for GEVs will be almost one million by 2015 [9]. It is clear that massive integration of GEVs on the power distribution system will result in a significant increase in electric energy demand and will raise load values at peak times [10]. Also, various studies have already been carried out to ...
... demand for GEVs will be almost one million by 2015 [9]. It is clear that massive integration of GEVs on the power distribution system will result in a significant increase in electric energy demand and will raise load values at peak times [10]. Also, various studies have already been carried out to ...
In this mode the PW is connected to the grid and the CW is short
... drives [1] [2] [4]. The BDFM consists of two electrically independent balanced three phase windings which have no mutual couplings and wound on the same core in the stator. The rotor circuit in BDFM is considered as a nested-loop type which couples to both fields of the stator and is actually the mo ...
... drives [1] [2] [4]. The BDFM consists of two electrically independent balanced three phase windings which have no mutual couplings and wound on the same core in the stator. The rotor circuit in BDFM is considered as a nested-loop type which couples to both fields of the stator and is actually the mo ...
DT U V in d en e rg i E R ap p o rt 2015 - DTU Orbit
... implemented in the WPP level, such as: • Balance control (absolute power de-rating) o whereby the WPP production can be adjusted downwards or upwards, in steps at constant levels. • Power ramp rate control o which sets how fast the wind farm power production, can be adjusted upwards and downwards. • ...
... implemented in the WPP level, such as: • Balance control (absolute power de-rating) o whereby the WPP production can be adjusted downwards or upwards, in steps at constant levels. • Power ramp rate control o which sets how fast the wind farm power production, can be adjusted upwards and downwards. • ...
Aalborg Universitet three-phase Voltage Source Inverters
... or slightly unbalanced three-phase loads, due to the coupling between the sharing of active power and negative-sequence load current. In [12], a negative-sequence conductance loop based on the output voltage decomposition is reported, where a droop relationship between the negative-sequence reactive ...
... or slightly unbalanced three-phase loads, due to the coupling between the sharing of active power and negative-sequence load current. In [12], a negative-sequence conductance loop based on the output voltage decomposition is reported, where a droop relationship between the negative-sequence reactive ...
PAM8008 Description Pin Assignments
... is recommended, placing as close as possible to the device’s VDD lead. For filtering lower-frequency noise signals, a large capacitor of 10µF (ceramic) or greater placed near the audio power amplifier is recommended. Input Capacitior (CI) Large input capacitors are both expensive and spce hungrt for ...
... is recommended, placing as close as possible to the device’s VDD lead. For filtering lower-frequency noise signals, a large capacitor of 10µF (ceramic) or greater placed near the audio power amplifier is recommended. Input Capacitior (CI) Large input capacitors are both expensive and spce hungrt for ...
Multilevel converters
... phase leg in addition to (m-1)main dc bus capacitors. With the assumption that all capacitors have the same voltage rating, an m-level diode-clamp inverter only requires (m-1) capacitors. In order to balance the capacitor charge and discharge, one may employ two or more switch combinations for middl ...
... phase leg in addition to (m-1)main dc bus capacitors. With the assumption that all capacitors have the same voltage rating, an m-level diode-clamp inverter only requires (m-1) capacitors. In order to balance the capacitor charge and discharge, one may employ two or more switch combinations for middl ...
DESIGNING AN UNINTERRUPTIBLE POWER SUPPLY BASED ON
... applications that require a wide input voltage range. The full-bridge converter with a phaseshift control has been used for high step-up applications. However, the phase shifted fullbridge converters [10,11] require lots of power switching devices and the associated control circuits. So, the manufac ...
... applications that require a wide input voltage range. The full-bridge converter with a phaseshift control has been used for high step-up applications. However, the phase shifted fullbridge converters [10,11] require lots of power switching devices and the associated control circuits. So, the manufac ...
LTC3414 - 4A, 4MHz, Monolithic Synchronous Step-Down Regulator
... The LTC®3414 is a high efficiency monolithic synchronous, step-down DC/DC converter utilizing a constant frequency, current mode architecture. It operates from an input voltage range of 2.25V to 5.5V and provides a regulated output voltage from 0.8V to 5V while delivering up to 4A of output current. ...
... The LTC®3414 is a high efficiency monolithic synchronous, step-down DC/DC converter utilizing a constant frequency, current mode architecture. It operates from an input voltage range of 2.25V to 5.5V and provides a regulated output voltage from 0.8V to 5V while delivering up to 4A of output current. ...
Excellence in Systems Protection
... surge condition. No power-follow occurs and the disturbance to the line voltage is minimal. Each line of the protector has two protector modules, a fuse, and two monitoring circuits. One protector module on each line is connected to neutral and the other module to ground. Refer to connection diagram ...
... surge condition. No power-follow occurs and the disturbance to the line voltage is minimal. Each line of the protector has two protector modules, a fuse, and two monitoring circuits. One protector module on each line is connected to neutral and the other module to ground. Refer to connection diagram ...
Causes and Effects of Transient Voltages
... Even these transients can be broken up into other categories identified by their frequency. 1. Mid-to-Low Frequency Transients, like lightning and utility capacitor switching propagate (travel) very well on electrical systems. Higher amplitudes tend to be damped by the building's distribution syste ...
... Even these transients can be broken up into other categories identified by their frequency. 1. Mid-to-Low Frequency Transients, like lightning and utility capacitor switching propagate (travel) very well on electrical systems. Higher amplitudes tend to be damped by the building's distribution syste ...
Balance and Single line to ground fault location in electrical
... Various fault location techniques have been developed to assist power system engineers in locating fault fast. By detecting fault fast, the correct faulted section could be isolated and therefore minimize restoration time. The restoration can be expedited if the location of the fault is either known ...
... Various fault location techniques have been developed to assist power system engineers in locating fault fast. By detecting fault fast, the correct faulted section could be isolated and therefore minimize restoration time. The restoration can be expedited if the location of the fault is either known ...
Electric power system

An electric power system is a network of electrical components used to supply, transmit and use electric power. An example of an electric power system is the network that supplies a region's homes and industry with power—for sizable regions, this power system is known as the grid and can be broadly divided into the generators that supply the power, the transmission system that carries the power from the generating centres to the load centres and the distribution system that feeds the power to nearby homes and industries. Smaller power systems are also found in industry, hospitals, commercial buildings and homes. The majority of these systems rely upon three-phase AC power—the standard for large-scale power transmission and distribution across the modern world. Specialised power systems that do not always rely upon three-phase AC power are found in aircraft, electric rail systems, ocean liners and automobiles.