DS600CLSA
... Advanced Sensor Protection Circuits “ASPC” Developed to protect the current transducer from typical fault conditions: ...
... Advanced Sensor Protection Circuits “ASPC” Developed to protect the current transducer from typical fault conditions: ...
High voltage power supplies t in electrostatic applications
... usually in the form of rectification and filtering in ac sources, and additional filtering in dc sources. Overload protection, EMI, EMC and monitoring circuits can also be found. The output of the input filter is typically a dc voltage source. This dc voltage provides the energy source for the inver ...
... usually in the form of rectification and filtering in ac sources, and additional filtering in dc sources. Overload protection, EMI, EMC and monitoring circuits can also be found. The output of the input filter is typically a dc voltage source. This dc voltage provides the energy source for the inver ...
Lecture 2 rev2
... [3] K. Nowka et al, “A 0.9 V to 1.95 V dynamic voltage-scalable and frequency-scalable 32 b PowerPC processor”, ISSCC ...
... [3] K. Nowka et al, “A 0.9 V to 1.95 V dynamic voltage-scalable and frequency-scalable 32 b PowerPC processor”, ISSCC ...
Full Article
... the requirement. The combined protection and control strategy is being proposed in the simulation results. INDEXTERMS: Doubly fed induction generator (DFIG), low voltage ride-through (LVRT), crowbar, battery energy storage system (BESS), Wind turbine (WT). I. INTRODUCTION In recent years, wind energ ...
... the requirement. The combined protection and control strategy is being proposed in the simulation results. INDEXTERMS: Doubly fed induction generator (DFIG), low voltage ride-through (LVRT), crowbar, battery energy storage system (BESS), Wind turbine (WT). I. INTRODUCTION In recent years, wind energ ...
BG26386390
... Cascade Voltage Switch Logic (CVSL) was developed in IBM as an improvement over the use of pseudo NMOS. It comes in two forms: single output and differential output (or Double rail). The later form of the logic is also called DCVSL (Differential Cascade Voltage Switch Logic). DCVSL is made of two N ...
... Cascade Voltage Switch Logic (CVSL) was developed in IBM as an improvement over the use of pseudo NMOS. It comes in two forms: single output and differential output (or Double rail). The later form of the logic is also called DCVSL (Differential Cascade Voltage Switch Logic). DCVSL is made of two N ...
Chapter02
... • Learn how to protect yourself and your equipment against the dangers of electricity • Learn how to work inside a computer case • Learn how to troubleshoot electrical problems Prepared and Design By Hijrat Afghan ...
... • Learn how to protect yourself and your equipment against the dangers of electricity • Learn how to work inside a computer case • Learn how to troubleshoot electrical problems Prepared and Design By Hijrat Afghan ...
Model BD-20A HIGH FREQUENCY GENERATOR OPERATING
... ventilated area. Do not use in a confined area where high concentrations of ozone gas can develop. 3.5.4 This instrument generates an output at the radio-frequency level. Users who wear a pacemaker or other medical electronic device which might be affected by radiofrequency waves are advised to cons ...
... ventilated area. Do not use in a confined area where high concentrations of ozone gas can develop. 3.5.4 This instrument generates an output at the radio-frequency level. Users who wear a pacemaker or other medical electronic device which might be affected by radiofrequency waves are advised to cons ...
Speed control of wound rotor induction motors by AC regulator
... Abstract-Wound-rotor induction motors are generally used for high torque and adjustable speed conditions. At lower speeds, either power is wasted in rotor resistances or power is pumped back from the rotor circuit to grid using different standard energy recovery methods. At low torque and low speed ...
... Abstract-Wound-rotor induction motors are generally used for high torque and adjustable speed conditions. At lower speeds, either power is wasted in rotor resistances or power is pumped back from the rotor circuit to grid using different standard energy recovery methods. At low torque and low speed ...
hill climbing techniques for tracking maximum power point in solar
... The PV systems connected directly to the load result in overall poor efficiency as such MPPT is to be introduced in PV systems to increase the efficiency of the system [1]. Solar radiation, load impedance and module temperature are the three factors which affect the maximum power extraction from sol ...
... The PV systems connected directly to the load result in overall poor efficiency as such MPPT is to be introduced in PV systems to increase the efficiency of the system [1]. Solar radiation, load impedance and module temperature are the three factors which affect the maximum power extraction from sol ...
Power System Harmonics
... 15%, the derating of the transformer would be so small that it can be neglected. On the other hand, when current THD exceeds 15%, the transformer capability should be evaluated by a professional using IEEE recommendations. It is important to clarify that these IEEE recommendations do not apply to tr ...
... 15%, the derating of the transformer would be so small that it can be neglected. On the other hand, when current THD exceeds 15%, the transformer capability should be evaluated by a professional using IEEE recommendations. It is important to clarify that these IEEE recommendations do not apply to tr ...
MAGTROL DES 310 and DES 311 Power Supplies DES
... ideally from the DSP6001 Dynamometer Controller. Control The Power supplies can be switched on by remote control. A stand-by command allows the dynamometer power to be activated. The excitation current is controlled by a set-point in the range of 0 to 10 VDC. The nominal value of the excitation curr ...
... ideally from the DSP6001 Dynamometer Controller. Control The Power supplies can be switched on by remote control. A stand-by command allows the dynamometer power to be activated. The excitation current is controlled by a set-point in the range of 0 to 10 VDC. The nominal value of the excitation curr ...
14PE15 Single Power-Conversion AC–DC Converter with High
... This paper proposes a single power-conversion ac–dc converter with high power factor and high efficiency. The proposed converter is derived by integrating a full-bridge diode rectifier and a series-resonant active-clamp dc–dc converter. To obtain a high power factor without a power factor correction ...
... This paper proposes a single power-conversion ac–dc converter with high power factor and high efficiency. The proposed converter is derived by integrating a full-bridge diode rectifier and a series-resonant active-clamp dc–dc converter. To obtain a high power factor without a power factor correction ...
Ledex® Drive Electronics and Coil Suppressors
... applied, no field exists. Applying a voltage will cause a field to be generated, which will be maintained as long as the voltage is applied. When the voltage is removed, the field must dissipate. Nearly everyone is familiar with spark plugs in gasoline engines. A spark is generated due to a voltage ...
... applied, no field exists. Applying a voltage will cause a field to be generated, which will be maintained as long as the voltage is applied. When the voltage is removed, the field must dissipate. Nearly everyone is familiar with spark plugs in gasoline engines. A spark is generated due to a voltage ...
Cooper Bussmann introduces SurgePOD™ Heavy Duty and Pro Type 1 SPDs 2/7/13 Cooper Bussmann expands its line of surge protective devices (SPDs) to include new Type 1 UL 1449 3rd Edition Listed SurgePOD™ Heavy Duty and Pro models. Read more
... models allow users to precisely match and protect electrical systems and equipment better than some “one size fits all” versions on the market today. ...
... models allow users to precisely match and protect electrical systems and equipment better than some “one size fits all” versions on the market today. ...
Component Electronic Systems
... Electricity is one of the most important forms of energy available to man. It affects everyone’s lives in many ways. If you take time to think about your everyday life you will realise that our lives are full of devices that depend upon electricity. These devices depend on the electrical circuits in ...
... Electricity is one of the most important forms of energy available to man. It affects everyone’s lives in many ways. If you take time to think about your everyday life you will realise that our lives are full of devices that depend upon electricity. These devices depend on the electrical circuits in ...
Power Meter 6460
... Meter requires no balancing or bias-current adjustments. It is as simple to operate as a conventional electronic voltmeter, the only pre-adjustment being that of normal zero setting. This is done with the instrument switched to maximum sensitivity, and no further zero adjustment is then necessary af ...
... Meter requires no balancing or bias-current adjustments. It is as simple to operate as a conventional electronic voltmeter, the only pre-adjustment being that of normal zero setting. This is done with the instrument switched to maximum sensitivity, and no further zero adjustment is then necessary af ...
Power Supply - e-Mady
... This unit converts the AC current into one or more levels of DC current that can be used by the computer. This unit regulates the input voltage and load variations. ...
... This unit converts the AC current into one or more levels of DC current that can be used by the computer. This unit regulates the input voltage and load variations. ...
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)
... Today’s there are a growing number of portable applications requiring small-area low-power highthroughput circuitry. Therefore, circuits with low power utilization grow to be the most important candidates for design of microprocessors and system mechanism. The battery technology does not advance at ...
... Today’s there are a growing number of portable applications requiring small-area low-power highthroughput circuitry. Therefore, circuits with low power utilization grow to be the most important candidates for design of microprocessors and system mechanism. The battery technology does not advance at ...
wireless and carrier communication based smart metering
... voltage and current property and report to the utility as discussed in earlier chapters, smart meter used in microgrid measures voltages and currents in all three phases. It also measures the active and reactive power in the circuit, unbalance properties can be easily detect from positive, negative ...
... voltage and current property and report to the utility as discussed in earlier chapters, smart meter used in microgrid measures voltages and currents in all three phases. It also measures the active and reactive power in the circuit, unbalance properties can be easily detect from positive, negative ...
Zener Diode Voltage Regulators
... There is no specific value for IZmin although it is typically taken to be ten percent of IZmax. It is possible that a lower value could be used particularly at Zener voltages greater than around six. This insures that the diode operating current is in the breakdown region and not in the soft transit ...
... There is no specific value for IZmin although it is typically taken to be ten percent of IZmax. It is possible that a lower value could be used particularly at Zener voltages greater than around six. This insures that the diode operating current is in the breakdown region and not in the soft transit ...
Electric power system
An electric power system is a network of electrical components used to supply, transmit and use electric power. An example of an electric power system is the network that supplies a region's homes and industry with power—for sizable regions, this power system is known as the grid and can be broadly divided into the generators that supply the power, the transmission system that carries the power from the generating centres to the load centres and the distribution system that feeds the power to nearby homes and industries. Smaller power systems are also found in industry, hospitals, commercial buildings and homes. The majority of these systems rely upon three-phase AC power—the standard for large-scale power transmission and distribution across the modern world. Specialised power systems that do not always rely upon three-phase AC power are found in aircraft, electric rail systems, ocean liners and automobiles.