• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Low power factor
Low power factor

... or cancel the inductive VAR in the installation. In this application, the motor is called a synchronous capacitor or synchronous condenser. It will be covered in greater detail in dealing with ac machines and synchronous motors. The single drawback to this method is the cost, both very high initial ...
PDF
PDF

... resistance, (2) lower self inductance, and (3) longer power cycle life (to be described later). Thermally Conductive electrically Isolated Layer (TCIL) has been inserted beneath the bottom surface of the heat spreader, and the sheet material was selected so that it has heat conductivity higher than ...
Power-Synchronization Control of Grid-Connected Voltage
Power-Synchronization Control of Grid-Connected Voltage

... in grid-connected applications, such as adjustable-speed drives (ASDs) with PWM rectifiers, power quality improvement, wind turbines, etc. [1]. Thanks to the gradually increased rating and reduced costs, they have also been applied for high-voltage dc (HVDC) transmission in recent years [2]. Compare ...
D1U3CS-D-1600-HC4EC Series
D1U3CS-D-1600-HC4EC Series

... choice of 3.3V (20W) standby and airflow direction. The power module is able to current share with up to eight (8) other power modules of the same type operating in parallel or N+1 redundancy. The supplies may be hot plugged, and include integral isolation devices. The power modules are fully protect ...
A Proto Type FPGA Based Reduced Switch Three Phase Inverter
A Proto Type FPGA Based Reduced Switch Three Phase Inverter

Q25085089
Q25085089

... Converter, working with an internal frequency of 20khz with an output power of 5kw. Since the ZVS range is independent of the switch capacitance, IGBT’S are used by adding the external capacitors to the switches without increasing the switching losses. However, it is not easy to design a hard-switch ...
2. Technical Aspects of Grid Interconnection
2. Technical Aspects of Grid Interconnection

... The fact that interconnections between power systems are increasingly common does not imply that they are as simple as connecting a few wires. Interconnections obviously entail the expense of constructing and operating transmission lines and substations, or in the case of HVDC, converter stations. I ...
Power System Harmonic Mitigation for Water
Power System Harmonic Mitigation for Water

... correction capacitors creating a parallel resonance at a particular harmonic frequency. Sources of Harmonics There are many sources of power system harmonics. Some examples of harmonic producing devices are: Transformers: Third harmonic currents are present in the magnetizing current (a small portio ...
1 - Mirus International
1 - Mirus International

... .1 As a standard feature, the HMRP shall come equipped with an HF3579 Passive Harmonic Filter. The filter shall be rated for the continuous duty maximum full load rating of the HMRP. .2 The HF3579 shall be designed to filter out the majority of the 3rd, 5th, 7th and 9th harmonic currents generated b ...
FENOC%
FENOC%

... the 138 kV line was due to an improper manufacturer's brazing process which may have provided less than full design cable holding capability. The root cause of this event is knowledge-based error. Site personnel did not recognize that the three legged WYE-G / WYE-G WYE-G secondary core form transfor ...
power factor correction using microcontroller
power factor correction using microcontroller

... The reactive power increases the current flowing between the power source and the load, which increases the power losses through transmission and distribution lines. This results in operational and financial losses for power companies. Therefore, power companies require their customers, especially t ...
Without interruption.
Without interruption.

XA SERIES - Nady Systems, Inc.
XA SERIES - Nady Systems, Inc.

... the air vents in the back side and front of the amplifier if the load seen by amplifier is less than 4 ohms and the amplifier is being run at high output levels. For best results, in such high output power applications you should augment the amplifier’s air flow with a rack cooling system. ...
Aalborg Universitet Trintis, Ionut; Ghimire, Pramod; Munk-Nielsen, Stig; Rannestad, Bjørn
Aalborg Universitet Trintis, Ionut; Ghimire, Pramod; Munk-Nielsen, Stig; Rannestad, Bjørn

... changing [4], [5]. Because of thermo-mechanical induced stress in interconnection and bondings, the onstate voltage is increased gradually with the number of loading cycles [6]. The progressive degradation in interconnection is occurred throughout the life where the device remains functional until a ...
Fuse Status Indicator Universal Power Alert
Fuse Status Indicator Universal Power Alert

... The Model UPA-130 Power Alert reduces the risk of electrical arc flash by pre-verifying the electrical isolation from the outside of a control panel. The Universal Power Alert is hardwired to the circuit breaker or main disconnect and has an LED indication whenever voltage is present. It is engineer ...
Triple Pulse Tester - Efficient Power Loss Characterization of Power Modules
Triple Pulse Tester - Efficient Power Loss Characterization of Power Modules

... must be used. An example of such a circuit of the collector-emitter voltage measurement introduced in [5] could be used. The on-stage voltage drop is measured only when the transistor or the diode is turned ON, while the circuit is able to block the high voltage when the transistor or diode is turne ...
Low-Power VLSI Circuit Design
Low-Power VLSI Circuit Design

PDF Print Version - Glassman High Voltage
PDF Print Version - Glassman High Voltage

High Current Low Voltage Solution For Microprocessor
High Current Low Voltage Solution For Microprocessor

Document
Document

...  many actuators are capacitive or inductive (such as motors and solenoids)  these create particular problems – particularly when using switching techniques  we will return to look at these problems when we have considered capacitor and inductors in more detail ...
GIGAVAC HXNC241 Normally Closed EPIC DC Contactor
GIGAVAC HXNC241 Normally Closed EPIC DC Contactor

... 4 Contactor has two coils. Both are used for pick-up, and then in approximately 75 milliseconds, one coil is electronically removed from the coil drive circuit. The remaining coil supplies low continuous hold power sufficient for the contactor to meet all of its specified performance specifications. ...
Novel Insights into Lossless AC and DC Power Flow
Novel Insights into Lossless AC and DC Power Flow

... numerically or approximated through the linear DC power flow. The latter serves as well-used approximation to obtain the phase angle differences near an acceptable operating point, but the accuracy of the DC approximation drops in a stressed grid. Here, we propose a modified DC approximation that ap ...
Test Stand for 325 MHz Power Couplers
Test Stand for 325 MHz Power Couplers

... cavities is very sensitive to dust particles. After conditioning the couplers, they will be installed directly onto cavities without any additional cleaning procedure. Thus disassembly of the test configuration should not create or spread dust particles. To satisfy this demand a configuration with ‘ ...
current - Actec A/S
current - Actec A/S

... 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line r ...
Calorimetry of Energy-Efficient Glow Discharge - Apparatus Design and Calibration
Calorimetry of Energy-Efficient Glow Discharge - Apparatus Design and Calibration

... 3 use an initial fixed gas pressure in a sealed glass envelope which is then independent of a vacuum system or a gas source and thus can be more fully enclosed for more accurate calorimetry than is practicable in the first method. Driver Power Supply The driving power for the glow discharge comes fr ...
< 1 ... 275 276 277 278 279 280 281 282 283 ... 561 >

Electric power system



An electric power system is a network of electrical components used to supply, transmit and use electric power. An example of an electric power system is the network that supplies a region's homes and industry with power—for sizable regions, this power system is known as the grid and can be broadly divided into the generators that supply the power, the transmission system that carries the power from the generating centres to the load centres and the distribution system that feeds the power to nearby homes and industries. Smaller power systems are also found in industry, hospitals, commercial buildings and homes. The majority of these systems rely upon three-phase AC power—the standard for large-scale power transmission and distribution across the modern world. Specialised power systems that do not always rely upon three-phase AC power are found in aircraft, electric rail systems, ocean liners and automobiles.