• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
8.  ELECTRIC POWER SYSTEMS 8.1  Introduction
8. ELECTRIC POWER SYSTEMS 8.1 Introduction

... generator or grid may not be available to the RCPs for a minimum of 3 seconds following a turbine trip. The COL applicant must perform a failure modes and effects analysis (FMEA) to ensure that the design provides power to the RCPs for a minimum of 3 seconds following a turbine trip. If the power to ...
Low-Power and High Speed High-to-Low Level Shifter
Low-Power and High Speed High-to-Low Level Shifter

... management techniques which will assure overall low-power and high speed performance. Various power reduction methodologies are currently known. One of most widely used techniques is supply voltage scaling for separate IC blocks. Supply voltage reduction will cause a decrease of overall power consum ...
Transient Suppression: Switching Power Supplies
Transient Suppression: Switching Power Supplies

... second product, the problem will be simple to solve. If the volt x second product is large and the source impedance low, the usual case, the solution will be more difficult. The following is written around a 28 volt DC aircraft power bus, where positive transients should be contained within the 35 t ...
Aalborg Universitet Wide-Scale Adoption of Photovoltaic Energy
Aalborg Universitet Wide-Scale Adoption of Photovoltaic Energy

... mitigate the challenges related to intermittency [31]. Today, several countries have already modified their grid codes for medium- or high-voltage renewable energy systems, and a few countries have also published similar requirements for low-voltage applications. For instance, the German grid code r ...
Voltage Collapse and Sympathy Trips 2014 OTS
Voltage Collapse and Sympathy Trips 2014 OTS

... • Since the generator electric angle is related to the position of the rotor. Any change in the rotor speed (due to the imbalance) will, in turn, result in changes in the generator output. There will be an interaction between the system and rotor speed. • The term “equal area criteria” is used to de ...
Introduction to Switched-Mode Power Supply (SMPS) Circuits
Introduction to Switched-Mode Power Supply (SMPS) Circuits

... regulation. It may sometimes be required to have output voltage regulation similar to the one provided by linear supplies and compactness and better efficiency of a switched mode supply. For this, the linear power supply may be put in tandem with a switched mode supply. • Let us consider a case wher ...
Training Systems for Electrical Power Engineering
Training Systems for Electrical Power Engineering

... By Supervisory Control and Data Acquisition (SCADA), we mean the monitoring, control and data acquisition of technical processes as they happen in real time. In electrical power engineering, SCADA is used to cover the entire spectrum from power generation, transmission – including protection measure ...
RF3826 30MHz TO 2500MHz, 9W GaN WIDEBAND POWER AMPLIFIER Features
RF3826 30MHz TO 2500MHz, 9W GaN WIDEBAND POWER AMPLIFIER Features

... MTTF (TJ < 200°C, 95% Confidence Limits)* ...
Triple II Demand Instruments
Triple II Demand Instruments

Neutral Point Clamped (Npc) Type Multilevel Inverter
Neutral Point Clamped (Npc) Type Multilevel Inverter

STP 3 &amp; 4 8.3  Onsite Power Systems
STP 3 & 4 8.3 Onsite Power Systems

... Conversely, the bus feeder breakers are interlocked such that they cannot close unless their associated grounding breakers are in their disconnect positions.Each medium voltage 4.16 kV bus has a spare space which can be used to insert a manual grounding circuit device for use during maintenance acti ...
A Capacitance-Compensation Technique for Improved Linearity in CMOS Class-AB Power Amplifiers
A Capacitance-Compensation Technique for Improved Linearity in CMOS Class-AB Power Amplifiers

... in complementary, metal-oxide-semiconductor (CMOS) technology. A key component of such a system would be the power amplifier (PA), and several workers have recently described implementations of CMOS PAs. However, most of these designs, such as those described in [1]–[4], were intended for constant-e ...
Examples of Electric Drive Solutions and Applied
Examples of Electric Drive Solutions and Applied

Buck/Boost DC–DC Converter Topology with Soft Switching for PV
Buck/Boost DC–DC Converter Topology with Soft Switching for PV

... proportional to load as in resonant converters. A detailed analysis of the DC-DC converter is discussed and simulation results obtained are presented. Keywords:Zero current switching (ZCS), Zero voltage switching (ZVS), PV panel, buck-boost converter, DC-DC converter ...
10 GigaBit Span Regeneration Tap with SFP Monitor Ports
10 GigaBit Span Regeneration Tap with SFP Monitor Ports

... Dimensions: 1.75" high x 13" deep x 17" wide, Weight: 5 lbs ...
G49045358
G49045358

... behave as nonlinear loads. These loads may create problems of high input current harmonics and excessive neutral current. The neutral current consists of mainly triplen harmonics currents. The zerosequence neutral current obtains a path through the neutral conductor. Moreover, the unbalanced singlep ...
“Capacitor Switching and Capacitor Switching Devices” Thomas P
“Capacitor Switching and Capacitor Switching Devices” Thomas P

Comprehensive Design of a Three-Phase Three-Switch
Comprehensive Design of a Three-Phase Three-Switch

1.1A, Single-Input 5-V Power Supply IC for
1.1A, Single-Input 5-V Power Supply IC for

... The bq25046 contains a thermal regulation loop that monitors the die temperature continuously. If the temperature exceeds TJ(REG), the device automatically reduces the input current limit to prevent the die temperature from increasing further. In some cases, the die temperature continues to rise des ...
Blackstart of An Induction Motor in An Autonomous Microgrid
Blackstart of An Induction Motor in An Autonomous Microgrid

... Abstract—Starting of large induction motors may produce voltage dip in a weak microgrid because of high current and reactive power demand in transient period. This paper develops a solution for black start issue of an Induction Motor (IM) using Voltage-Sourced Converter (VSC) interfaced source in an ...
EE410Lab4
EE410Lab4

... The efficiency plot of the buck converter was taken with different voltage inputs to compare which input voltage and at what percent load the DC-DC converter is most power efficient. The input value that was the least efficient was the highest voltage of Vin= 15V. The trend between voltages showed t ...
P85324_ E50_MULTICANDELA_SPEAKER_SPEAKERSTROBE
P85324_ E50_MULTICANDELA_SPEAKER_SPEAKERSTROBE

View Slideshow
View Slideshow

... • Advanced algorithms for more optimal results • Dynamic compaction for more complicated ...
Reduced wiring system (CC-Link compliant SI unit) EX140
Reduced wiring system (CC-Link compliant SI unit) EX140

... Insulation failure (interference with other circuit, poor insulation between terminals and etc.) could introduce excessive voltage or current to the reduced-wiring system or each I/O device and damage them. • Separate power line for solenoid valves from power line for input and control unit. Otherwi ...
Class notes on controlled rectifiers
Class notes on controlled rectifiers

< 1 ... 228 229 230 231 232 233 234 235 236 ... 561 >

Electric power system



An electric power system is a network of electrical components used to supply, transmit and use electric power. An example of an electric power system is the network that supplies a region's homes and industry with power—for sizable regions, this power system is known as the grid and can be broadly divided into the generators that supply the power, the transmission system that carries the power from the generating centres to the load centres and the distribution system that feeds the power to nearby homes and industries. Smaller power systems are also found in industry, hospitals, commercial buildings and homes. The majority of these systems rely upon three-phase AC power—the standard for large-scale power transmission and distribution across the modern world. Specialised power systems that do not always rely upon three-phase AC power are found in aircraft, electric rail systems, ocean liners and automobiles.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report