Old Company Name in Catalogs and Other Documents
... subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm the latest product information with a Renesas Electronics sales office. Also, please pay regular and careful attention to additional and different information to be d ...
... subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm the latest product information with a Renesas Electronics sales office. Also, please pay regular and careful attention to additional and different information to be d ...
ProSafe Isolation Transformer - Marlow
... This is a high quality product, however, it is possible to unknowingly abuse or misapply a transforme r, therefore reducing its life expectancy. These installation and operation instructions set out the guidelines for peak performance of the ProSafe Isolation T ransformer. The information contained ...
... This is a high quality product, however, it is possible to unknowingly abuse or misapply a transforme r, therefore reducing its life expectancy. These installation and operation instructions set out the guidelines for peak performance of the ProSafe Isolation T ransformer. The information contained ...
BD5423AEFS
... safety measure such as fuse, against a special mode that may violate conditions of absolute maximum ratings. 2. About power supply line As return of current regenerated by back EMF of output coil happens, take steps such as putting capacitor between power supply and GND as a electric pathway for the ...
... safety measure such as fuse, against a special mode that may violate conditions of absolute maximum ratings. 2. About power supply line As return of current regenerated by back EMF of output coil happens, take steps such as putting capacitor between power supply and GND as a electric pathway for the ...
excitation systems
... 8.6.3 Modeling of Complete Excitation Systems Figure 8.39 depicts the general structure of a detailed excitation system model having a one-to-one correspondence with the physical equipment. While this model structure has the advantage of retaining a direct relationship between model parameters and ...
... 8.6.3 Modeling of Complete Excitation Systems Figure 8.39 depicts the general structure of a detailed excitation system model having a one-to-one correspondence with the physical equipment. While this model structure has the advantage of retaining a direct relationship between model parameters and ...
Aalborg Universitet EHV/HV Underground Cable Systems for Power Transmission Bak, Claus Leth
... OHL/UGC line was conducted in 2005 by Kim Søgaard in his MSc thesis. The main findings were: • When switching the line off the 50 Hz system, it will start resonating with a frequency equal to its resonant frequency given by its inductances and capacitances, which are dominated by the shunt reactor ...
... OHL/UGC line was conducted in 2005 by Kim Søgaard in his MSc thesis. The main findings were: • When switching the line off the 50 Hz system, it will start resonating with a frequency equal to its resonant frequency given by its inductances and capacitances, which are dominated by the shunt reactor ...
Design of High Speed Low Power 15-4 Compressor
... There are several types of static adiabatic logic circuits, namely, Complementary Energy Path Adiabatic Logic (CEPAL), Quasi Static Energy Recovery Logic (QSERL) and Quasi Static Singlephase Energy Recovery Logic (QSSERL). They are all designed to overcome the drawbacks of the previously available i ...
... There are several types of static adiabatic logic circuits, namely, Complementary Energy Path Adiabatic Logic (CEPAL), Quasi Static Energy Recovery Logic (QSERL) and Quasi Static Singlephase Energy Recovery Logic (QSSERL). They are all designed to overcome the drawbacks of the previously available i ...
UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION WASHINGTON, DC 20555-0001
... the grid can cause adverse effects on the operation of Class 1E loads. These degraded voltage conditions will not be detected by the Loss-of-Voltage Relays (LVRs) which are designed to detect loss of power to the bus from the offsite circuit(s). The LVR’s low voltage dropout setting is generally in ...
... the grid can cause adverse effects on the operation of Class 1E loads. These degraded voltage conditions will not be detected by the Loss-of-Voltage Relays (LVRs) which are designed to detect loss of power to the bus from the offsite circuit(s). The LVR’s low voltage dropout setting is generally in ...
The RF Line
... data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. Motorola does not convey any license under its patent ...
... data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. Motorola does not convey any license under its patent ...
Freescale`s 50 V RF LDMOS: An Ideal RF Power Technology for ISM
... ruggedness variant (EVHV6), including advantages over competing device technologies. Ruggedness expectations and requirements for RF power devices targeting ISM applications are more stringent than for devices designed for less challenging applications like cellular infrastructure. This paper will i ...
... ruggedness variant (EVHV6), including advantages over competing device technologies. Ruggedness expectations and requirements for RF power devices targeting ISM applications are more stringent than for devices designed for less challenging applications like cellular infrastructure. This paper will i ...
Lecture 7 Power Consumption in CMOS Circuits and Low Power
... • Leakage power as a fraction of the total power increases as clock frequency drops. Turning supply off in unused parts can save power. • For a gate it is a small fraction of the total power; it can be significant for very large circuits. • Scaling down features requires lowering the threshold volta ...
... • Leakage power as a fraction of the total power increases as clock frequency drops. Turning supply off in unused parts can save power. • For a gate it is a small fraction of the total power; it can be significant for very large circuits. • Scaling down features requires lowering the threshold volta ...
Design of Lightning Arresters for Electrical Power Systems Protection
... losses, high level reliability in the operation time, high speed response to the over-voltages, simplicity of design, easier for maintenance and long life time. Accurate modeling and simulation of their dynamic characteristics are very important for arrester allocation, systems reliability and insul ...
... losses, high level reliability in the operation time, high speed response to the over-voltages, simplicity of design, easier for maintenance and long life time. Accurate modeling and simulation of their dynamic characteristics are very important for arrester allocation, systems reliability and insul ...
Energy scavenging for medical applications - Eit.lth.se
... source, at concept level. After this first sorting, left was a number of papers each one containing useful information about energy scavenging. However, many of these articles covered each other, presenting the same information multiple times. Few of them covered energy harvesting in a lager scale, ...
... source, at concept level. After this first sorting, left was a number of papers each one containing useful information about energy scavenging. However, many of these articles covered each other, presenting the same information multiple times. Few of them covered energy harvesting in a lager scale, ...
A Study of De-Excitation after Abrupt 3
... magnetic energy absorbed. ---value of d-axis mutual inductance Lad’ of loading generator is in saturation area ,and can be determined by simulation. The saturation can be ignored when 3-phase short circuit happens. Obviously armature reaction in this case is quite big to cancel some effect of field ...
... magnetic energy absorbed. ---value of d-axis mutual inductance Lad’ of loading generator is in saturation area ,and can be determined by simulation. The saturation can be ignored when 3-phase short circuit happens. Obviously armature reaction in this case is quite big to cancel some effect of field ...
Power Systems Lab Manual - Electrical and Computer Engineering
... to take it (of course with permission and always reference the source), and state its role, as you understand it at this stage in your study, in operation and protection of power systems. State the approximate physical size and the electric ratings in terms of voltage, current, power, kVA etc. These ...
... to take it (of course with permission and always reference the source), and state its role, as you understand it at this stage in your study, in operation and protection of power systems. State the approximate physical size and the electric ratings in terms of voltage, current, power, kVA etc. These ...
Determining Electric Motor Load and Efficiency
... devices, software methods, and analytical methods. The special devices package all or most of the required instrumentation in a portable box. Software and analytical methods require generic portable instruments for measuring watts, vars, resistance, volts, amps, and speed. These need to be instrumen ...
... devices, software methods, and analytical methods. The special devices package all or most of the required instrumentation in a portable box. Software and analytical methods require generic portable instruments for measuring watts, vars, resistance, volts, amps, and speed. These need to be instrumen ...
Three Phase Theory- Professor J R Lucas As you are aware, to
... Three Phase Theory - Professor J R Lucas As you are aware, to transmit power with single phase alternating current, we need two wires (live wire and neutral). However you would have seen that distribution lines usually have only 4 wires. This is because distribution is done using three phase and the ...
... Three Phase Theory - Professor J R Lucas As you are aware, to transmit power with single phase alternating current, we need two wires (live wire and neutral). However you would have seen that distribution lines usually have only 4 wires. This is because distribution is done using three phase and the ...
Tyco Compact Power Line Shelves
... wide without the mounting ears, is designed to fit inside a 19-inch rack of customer equipment. Shelves can also be mounted directly to the 19inch frame using the adjustable mounting ears. These adjustments permit positioning of the shelf either flush or extended outward in two steps. Another config ...
... wide without the mounting ears, is designed to fit inside a 19-inch rack of customer equipment. Shelves can also be mounted directly to the 19inch frame using the adjustable mounting ears. These adjustments permit positioning of the shelf either flush or extended outward in two steps. Another config ...
Low Power Design and Battery Operation with the MC1322x
... — Signal SWITCH1 is connected to KBI_4 and can be used as a wake-up interrupt to the MC1322x (See the CRM chapter of the MC1322x Reference Manual). — Signal SWITCH2 is connected to KBI_0 and can be used as a wake-up signal from the MC1322x to an external device. (See the CRM chapter of the MC1322x R ...
... — Signal SWITCH1 is connected to KBI_4 and can be used as a wake-up interrupt to the MC1322x (See the CRM chapter of the MC1322x Reference Manual). — Signal SWITCH2 is connected to KBI_0 and can be used as a wake-up signal from the MC1322x to an external device. (See the CRM chapter of the MC1322x R ...
Getting the Best Performance from AC to DC Power
... The segment of power electronics is growing with a faster rhythm than other sectors, as a matter of fact, thanks to increasing research on intelligent, reliable, energy efficient and environmentally sustainable solutions, necessarily linked to the world of power. In this dynamic context, Power Fortr ...
... The segment of power electronics is growing with a faster rhythm than other sectors, as a matter of fact, thanks to increasing research on intelligent, reliable, energy efficient and environmentally sustainable solutions, necessarily linked to the world of power. In this dynamic context, Power Fortr ...
EET-222-ELECTRICAL MC-II
... Induction motors are used worldwide in many residential, commercial, industrial, and utility applications. Induction Motors transform electrical energy into mechanical energy. It can be part of a pump or fan, or connected to some other form of mechanical equipment such as a winder, conveyor, or mixe ...
... Induction motors are used worldwide in many residential, commercial, industrial, and utility applications. Induction Motors transform electrical energy into mechanical energy. It can be part of a pump or fan, or connected to some other form of mechanical equipment such as a winder, conveyor, or mixe ...
How to Install a PowerNet™ IPBridge Copyright © 2013, ISONAS Security Systems
... 4.1: PoE POWER PoE power can used to power the IPBridge itself and is commonly used to provide power to the components at the door, such as an electric lock, a Wiegand device, and/or a passive infrared motion detector. The IPBridge can be use two types of PoE. PoE ( IEEE 802.3af ) --- 13 watts of po ...
... 4.1: PoE POWER PoE power can used to power the IPBridge itself and is commonly used to provide power to the components at the door, such as an electric lock, a Wiegand device, and/or a passive infrared motion detector. The IPBridge can be use two types of PoE. PoE ( IEEE 802.3af ) --- 13 watts of po ...
Electric power system
An electric power system is a network of electrical components used to supply, transmit and use electric power. An example of an electric power system is the network that supplies a region's homes and industry with power—for sizable regions, this power system is known as the grid and can be broadly divided into the generators that supply the power, the transmission system that carries the power from the generating centres to the load centres and the distribution system that feeds the power to nearby homes and industries. Smaller power systems are also found in industry, hospitals, commercial buildings and homes. The majority of these systems rely upon three-phase AC power—the standard for large-scale power transmission and distribution across the modern world. Specialised power systems that do not always rely upon three-phase AC power are found in aircraft, electric rail systems, ocean liners and automobiles.