
Inside Computers 1
... to the various components within the computer, PSUs can either be internal or external, A PSU is a step down transformer converting 230V AC into a lower voltage – in a desktop computer its 12v / 5v DC, There are various cables with different connectors coming out of a PSU – the different connectors ...
... to the various components within the computer, PSUs can either be internal or external, A PSU is a step down transformer converting 230V AC into a lower voltage – in a desktop computer its 12v / 5v DC, There are various cables with different connectors coming out of a PSU – the different connectors ...
AN-4191 - Advanced GreenBridge™ Technology Enables
... and clean circuit layout. It achieves high power density due to low on-resistance (RDS(ON)) switches from the Fairchild shielded gate power trench MOSFET technology; and also provides compliance with the PoE standard described in IEEE802.3at. The validation of the FDMQ8205 increased efficiency in Po ...
... and clean circuit layout. It achieves high power density due to low on-resistance (RDS(ON)) switches from the Fairchild shielded gate power trench MOSFET technology; and also provides compliance with the PoE standard described in IEEE802.3at. The validation of the FDMQ8205 increased efficiency in Po ...
isscc 2010 / session 5 / processors / 5.5
... Achieved numbers varied by function, but installed clock gating numbers up to 95% were common, resulting in an AC power savings of up to 32% (40W). Gating of top-level clock grids is not implemented since physical separation would introduce skew between grids and would only reduce clock power by an ...
... Achieved numbers varied by function, but installed clock gating numbers up to 95% were common, resulting in an AC power savings of up to 32% (40W). Gating of top-level clock grids is not implemented since physical separation would introduce skew between grids and would only reduce clock power by an ...
Topic 12.3 Transmission of Electrical Power
... France. �The New Zealand high-voltage direct current scheme has around 610 km of overhead and submarine transmission lines. ...
... France. �The New Zealand high-voltage direct current scheme has around 610 km of overhead and submarine transmission lines. ...
RIII Area Grid Operations - The United States Nuclear Infrastructure
... Reactive power (VARs) is the component of total power that maintains voltages across the system Sufficient voltage is maintained by supplying the transmission system with reactive power from generating stations and static devices (capacitors) Customer loads consume reactive power, as do heavily load ...
... Reactive power (VARs) is the component of total power that maintains voltages across the system Sufficient voltage is maintained by supplying the transmission system with reactive power from generating stations and static devices (capacitors) Customer loads consume reactive power, as do heavily load ...
Marist College Advanced Facilities Course Topics Prof. Peter Curtis
... industry. As our reliance on computer technologies increases, our need for clean, uninterrupted power to keep this technology running is equally increasing. Students will learn about the opportunity cost of downtime, and associated ROI by developing a technical maintenance program, instituting an em ...
... industry. As our reliance on computer technologies increases, our need for clean, uninterrupted power to keep this technology running is equally increasing. Students will learn about the opportunity cost of downtime, and associated ROI by developing a technical maintenance program, instituting an em ...
Inverter Charger Switches Explanation
... This switch can change the low battery disconnect between 10.0V-11.5V. Depending on whether shore power is present or not the low voltage set point will change. For most applications, the voltage should be set to 11.5V to prevent the batteries from being depleted. NOTE: The switch positions are depe ...
... This switch can change the low battery disconnect between 10.0V-11.5V. Depending on whether shore power is present or not the low voltage set point will change. For most applications, the voltage should be set to 11.5V to prevent the batteries from being depleted. NOTE: The switch positions are depe ...
The Franck-Hertz Experiment Data Studio Version
... measure the very small collector current and your ThinkPad to log and plot the data in an XY plot. The tube contains a small amount of mercury, some of which vaporizes in the heat of the oven (~180°C). The oxide-coated cathode emits electrons when heated by the filament. These electrons are released ...
... measure the very small collector current and your ThinkPad to log and plot the data in an XY plot. The tube contains a small amount of mercury, some of which vaporizes in the heat of the oven (~180°C). The oxide-coated cathode emits electrons when heated by the filament. These electrons are released ...
Investigation of a magnetic flux compression by plasma liner.
... generators [2], plasma switch [3], exploding foils and wires [4], plasma breakers of current [5]. The schemes [3], [4], and [5] are able to reduce the pulse duration up to ~ 0.1 µs. The most complex is to make the current pulse shorter than 0.1 µs. For the experimental progress it’s necessary to inc ...
... generators [2], plasma switch [3], exploding foils and wires [4], plasma breakers of current [5]. The schemes [3], [4], and [5] are able to reduce the pulse duration up to ~ 0.1 µs. The most complex is to make the current pulse shorter than 0.1 µs. For the experimental progress it’s necessary to inc ...
i-class Induction Heating
... And a 9-pin.-Sub-D-Interface to load up new Firmware. Optional an additional Interface (also after installation) can be installed. These interface-cards are available as Profibus, Interbus-S, DeviceNet, RS 232/485 and others. ...
... And a 9-pin.-Sub-D-Interface to load up new Firmware. Optional an additional Interface (also after installation) can be installed. These interface-cards are available as Profibus, Interbus-S, DeviceNet, RS 232/485 and others. ...
VKM03,SR01 Rev. E
... 1 Input to Multiple outputs connections via a Gigabit network switch Recommend installation using an independent Gigabit LAN; do not link with existing LAN to avoid a lot of video data transmission slow down your network system. When using multiple transmitters and receivers via a Gigabit network sw ...
... 1 Input to Multiple outputs connections via a Gigabit network switch Recommend installation using an independent Gigabit LAN; do not link with existing LAN to avoid a lot of video data transmission slow down your network system. When using multiple transmitters and receivers via a Gigabit network sw ...
FSP 150CC-T3204 - ADVA Optical Networking
... Our FSP 150CC-T3204 provides Carrier Ethernet 2.0 service extension over one or two bonded T3 or E3 facilities with up to 89Mbit/s or 68Mbit/s, respectively. With four Ethernet service ports and advanced servicedefinition capabilities, the FSP 150CC-T3204 is capable of supporting multiple services o ...
... Our FSP 150CC-T3204 provides Carrier Ethernet 2.0 service extension over one or two bonded T3 or E3 facilities with up to 89Mbit/s or 68Mbit/s, respectively. With four Ethernet service ports and advanced servicedefinition capabilities, the FSP 150CC-T3204 is capable of supporting multiple services o ...
High-Side Power Monitor Measures Both Current and Voltage up to
... a high side power monitor that measures current and input voltages from 7V to 80V. The LTC4151 utilizes an internal 12-bit ADC to continuously measure both high side current and input voltage to give a true power reading. The LTC4151 replaces prior solutions that use costly current sense amplifiers ...
... a high side power monitor that measures current and input voltages from 7V to 80V. The LTC4151 utilizes an internal 12-bit ADC to continuously measure both high side current and input voltage to give a true power reading. The LTC4151 replaces prior solutions that use costly current sense amplifiers ...
Light Sources
... The AvaLight-CAL is a spectral calibration lamp. It is available with different gasses, the standard is HgAr, that emits all mercury and argon lines from 254 to well over 922 nm. The major lines and structures are shown on the bottom surface including their relative intensity. With the standard SMA ...
... The AvaLight-CAL is a spectral calibration lamp. It is available with different gasses, the standard is HgAr, that emits all mercury and argon lines from 254 to well over 922 nm. The major lines and structures are shown on the bottom surface including their relative intensity. With the standard SMA ...
Document
... bidirectional switch are employed. The primary windings of the two transformers are in series and the secondary windings are in parallel. With optimized dual-phase-shift modulation strategies, zero voltage switching (ZVS) is achieved for both the primaryand secondary-side power MOSFETs in a wide loa ...
... bidirectional switch are employed. The primary windings of the two transformers are in series and the secondary windings are in parallel. With optimized dual-phase-shift modulation strategies, zero voltage switching (ZVS) is achieved for both the primaryand secondary-side power MOSFETs in a wide loa ...
chapter 8 - Power Quality
... Utilities transmit electricity over power lines into home as an alternating current (AC) wave. This is how power travels through wiring and passes into appliances. ...
... Utilities transmit electricity over power lines into home as an alternating current (AC) wave. This is how power travels through wiring and passes into appliances. ...
PREMIUM POWER - Murrelektronik
... (PWM) makes this possible: The circuit supplies full power to energize the solenoid and shift the valve, then reduces the power when maintaining its position. Murrelektronik offers capacity reducers for contactors, to integrate into Cube20S fieldbus stations and as integral component of valve connec ...
... (PWM) makes this possible: The circuit supplies full power to energize the solenoid and shift the valve, then reduces the power when maintaining its position. Murrelektronik offers capacity reducers for contactors, to integrate into Cube20S fieldbus stations and as integral component of valve connec ...
Power over Ethernet

Power over Ethernet or PoE describes any of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras. Unlike standards such as Universal Serial Bus which also power devices over the data cables, PoE allows long cable lengths. Power may be carried on the same conductors as the data, or it may be carried on dedicated conductors in the same cable.There are several common techniques for transmitting power over Ethernet cabling. Two of them have been standardized by IEEE 802.3. Since only two of the four pairs are needed for 10BASE-T or 100BASE-TX, power may be transmitted on the unused conductors of a cable. In the IEEE standards, this is referred to as Alternative B. Power may also be transmitted on the data conductors by applying a common-mode voltage to each pair. Because twisted-pair Ethernet uses differential signalling, this does not interfere with data transmission. The common mode voltage is easily extracted using the center tap of the standard Ethernet pulse transformer. This is similar to the phantom power technique commonly used for powering audio microphones. In the IEEE standards, this is referred to as Alternative A.In addition to standardizing existing practice for spare-pair and common-mode data pair power transmission, the IEEE PoE standards provide for signalling between the power sourcing equipment (PSE) and powered device (PD). This signaling allows the presence of a conformant device to be detected by the power source, and allows the device and source to negotiate the amount of power required or available. Up to a 25.5 watts is available for a device.