
Introduction - College of William and Mary
... Surge protectors are equipped with a metal oxide varistor (MOV) inside the casing. The MOV acts like an electrical sponge because it absorbs dangerous excess voltage and prevents most of it from reaching sensitive equipment. But like a sponge, surge protectors have a limited capacity to absorb. Once ...
... Surge protectors are equipped with a metal oxide varistor (MOV) inside the casing. The MOV acts like an electrical sponge because it absorbs dangerous excess voltage and prevents most of it from reaching sensitive equipment. But like a sponge, surge protectors have a limited capacity to absorb. Once ...
USER`S GUIDE
... This product is a Safety Class 1 instrument (provided with a protective earth terminal). To minimize shock hazard, the instrument chassis and cover must be connected to an electrical ground. The instrument must be connected to the ac power mains through a grounded power cable, with the ground wire f ...
... This product is a Safety Class 1 instrument (provided with a protective earth terminal). To minimize shock hazard, the instrument chassis and cover must be connected to an electrical ground. The instrument must be connected to the ac power mains through a grounded power cable, with the ground wire f ...
Tier-1 ISP
... QoS needed for audio, voice, video Original Wi-Fi® didn’t have QoS IEEE 802.11e is new QoS standard ...
... QoS needed for audio, voice, video Original Wi-Fi® didn’t have QoS IEEE 802.11e is new QoS standard ...
DS3904/DS3905 Triple 128-Position Nonvolatile Digital Variable
... The DS3904/DS3905 must receive an 8-bit device address byte following a start condition to enable a specific device for a read or write operation. The address byte is clocked into the DS3904/DS3905 MSB to LSB. For the DS3904, the address byte consists of 101000 binary followed by A0 then the R/W bit ...
... The DS3904/DS3905 must receive an 8-bit device address byte following a start condition to enable a specific device for a read or write operation. The address byte is clocked into the DS3904/DS3905 MSB to LSB. For the DS3904, the address byte consists of 101000 binary followed by A0 then the R/W bit ...
Aggregation of Reactive Power
... transformer or other connection to the Commercial Boundary with another Generating Unit one of the above but with more than one possible route of connection to the Commercial Boundary ...
... transformer or other connection to the Commercial Boundary with another Generating Unit one of the above but with more than one possible route of connection to the Commercial Boundary ...
Phase-shifting Transformer Modeling in PSS®E
... For short circuit calculations the phase-shifting transformer model for the negative sequence network will employ the same leakage impedance used in the load flow calculations, but the sign of the phase shift angle will be reversed. Hence, if the phase shift angle is +Φ in the positive sequence netw ...
... For short circuit calculations the phase-shifting transformer model for the negative sequence network will employ the same leakage impedance used in the load flow calculations, but the sign of the phase shift angle will be reversed. Hence, if the phase shift angle is +Φ in the positive sequence netw ...
SEL-735 Power Quality and Revenue Meter
... The VOLT_SCA, POWR_SCA, ENRG_SCA, and PRI_SCA configuration settings affect how the meter reports quantities to communications channels and internal and external interfaces. The meter always reports LDP1 energy values as change-over-internal (COI) in primary kilo units to ensure compatibility with M ...
... The VOLT_SCA, POWR_SCA, ENRG_SCA, and PRI_SCA configuration settings affect how the meter reports quantities to communications channels and internal and external interfaces. The meter always reports LDP1 energy values as change-over-internal (COI) in primary kilo units to ensure compatibility with M ...
FANUC 16i/18i/21i Ethernet Settings
... The PCMCIA Ethernet card is to be inserted into the memory card slot to the left of the front LCD for temporary communication. NOTE 1 Use the PCMCIA Ethernet card for temporary communication only. Do not use the PCMCIA Ethernet card for routine communication. 2 The PCMCIA Ethernet card is to be inse ...
... The PCMCIA Ethernet card is to be inserted into the memory card slot to the left of the front LCD for temporary communication. NOTE 1 Use the PCMCIA Ethernet card for temporary communication only. Do not use the PCMCIA Ethernet card for routine communication. 2 The PCMCIA Ethernet card is to be inse ...
Document
... High-Speed Differential Protection. A two-stage slope adapts automatically to external fault conditions, providing fast, sensitive, dependable, and secure differential protection, even for CT saturation and heavily distorted waveforms. Multiple Synchrophasor Data Channels. System-wide monitoring is ...
... High-Speed Differential Protection. A two-stage slope adapts automatically to external fault conditions, providing fast, sensitive, dependable, and secure differential protection, even for CT saturation and heavily distorted waveforms. Multiple Synchrophasor Data Channels. System-wide monitoring is ...
Cable Coupler Overview
... When used with a suitable ground-check monitoring system, UEE quick-connect couplers are completely safe, even for high-voltage systems. The UEE conductor arrangement ensures that power cannot be turned on until the couplers are completely connected. Should a coupler in a live circuit be disconnecte ...
... When used with a suitable ground-check monitoring system, UEE quick-connect couplers are completely safe, even for high-voltage systems. The UEE conductor arrangement ensures that power cannot be turned on until the couplers are completely connected. Should a coupler in a live circuit be disconnecte ...
Power supplies and transformers Phaseo Creator of energy from 0.3
... for the control circuits of automation system equipment. Split into three families, this range meets all the needs encountered in industrial, commercial and residential applications. Single-phase or 3-phase, of the electronic switch mode type, they provide a quality of output which is suitable for t ...
... for the control circuits of automation system equipment. Split into three families, this range meets all the needs encountered in industrial, commercial and residential applications. Single-phase or 3-phase, of the electronic switch mode type, they provide a quality of output which is suitable for t ...
AD5110,12,14 - Analog Devices
... and EEPROM content. Resistor tolerance is stored within EEPROM, providing an end-to-end tolerance accuracy of 0.1%. The AD5110/AD5112/AD5114 are available in a 2 mm × 2 mm LFCSP package. The parts are guaranteed to operate over the extended industrial temperature range of −40°C to +125°C. ...
... and EEPROM content. Resistor tolerance is stored within EEPROM, providing an end-to-end tolerance accuracy of 0.1%. The AD5110/AD5112/AD5114 are available in a 2 mm × 2 mm LFCSP package. The parts are guaranteed to operate over the extended industrial temperature range of −40°C to +125°C. ...
Kintex-7 FPGA CES Errata Introduction
... Out-of-Band Signaling The GTX transceiver circuitry for out-of-band (OOB) signaling is always enabled. ...
... Out-of-Band Signaling The GTX transceiver circuitry for out-of-band (OOB) signaling is always enabled. ...
80 SBO Service Manual - ASL Technologies, LLC!
... polyofin, water in concentrations of 400 ppm or less will not disrupt normal operations, although microamp readings of the fluid will be slightly higher due to the conductivity of water. The cell operates with alternating electrostatic and magnetic fields. If, for example, a particle is negative, it ...
... polyofin, water in concentrations of 400 ppm or less will not disrupt normal operations, although microamp readings of the fluid will be slightly higher due to the conductivity of water. The cell operates with alternating electrostatic and magnetic fields. If, for example, a particle is negative, it ...
Peak Power Tracking and Multi-Thruster Control in Direct Drive
... Peak power tracking is simply the management of loads on a power system to extract the maximum power available from a solar array. In graphical terms, it is the operation of a system at the peak power point of the solar array power-voltage (P-V) curve, an example of which is shown in Fig. 1. NASA ro ...
... Peak power tracking is simply the management of loads on a power system to extract the maximum power available from a solar array. In graphical terms, it is the operation of a system at the peak power point of the solar array power-voltage (P-V) curve, an example of which is shown in Fig. 1. NASA ro ...
ups howto - The Linux Documentation Project
... UPSes are nowadays very inexpensive. In the U.S. in 2006, quite capable ones are available for less than $100, and prices are heading down. In fact prices are so low now that we're not going to walk you through the elaborate optimization step that would have been important even two or three years ag ...
... UPSes are nowadays very inexpensive. In the U.S. in 2006, quite capable ones are available for less than $100, and prices are heading down. In fact prices are so low now that we're not going to walk you through the elaborate optimization step that would have been important even two or three years ag ...
ISL12026, ISL12026A Datasheet
... SDA is a bidirectional pin used to transfer data into and out of the device. It has an open drain output and may be wire ORed with other open drain or open collector outputs. The input buffer is always active (not gated). This open drain output requires the use of a pull-up resistor. The pull-up res ...
... SDA is a bidirectional pin used to transfer data into and out of the device. It has an open drain output and may be wire ORed with other open drain or open collector outputs. The input buffer is always active (not gated). This open drain output requires the use of a pull-up resistor. The pull-up res ...
FM HD Radio System - Gates Harris History
... In the ten digit part numbers, if the last three numbers are 000, the item is a part that Harris has purchased and has not manufactured or modified. If the last three numbers are other than 000, the item is either manufactured by Harris or is purchased from a vendor and modified for use in the Harri ...
... In the ten digit part numbers, if the last three numbers are 000, the item is a part that Harris has purchased and has not manufactured or modified. If the last three numbers are other than 000, the item is either manufactured by Harris or is purchased from a vendor and modified for use in the Harri ...
Accurate Fault Location Algorithm on Power Transmission Lines
... Digital measurements at different line terminals can be performed synchronously if the global positioning system (GPS) [3] is available. Otherwise, or in case of loss of the signal from the GPS, the digital measurements from the line terminals are acquired asynchronously and, thus, do not have a com ...
... Digital measurements at different line terminals can be performed synchronously if the global positioning system (GPS) [3] is available. Otherwise, or in case of loss of the signal from the GPS, the digital measurements from the line terminals are acquired asynchronously and, thus, do not have a com ...
Power over Ethernet

Power over Ethernet or PoE describes any of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras. Unlike standards such as Universal Serial Bus which also power devices over the data cables, PoE allows long cable lengths. Power may be carried on the same conductors as the data, or it may be carried on dedicated conductors in the same cable.There are several common techniques for transmitting power over Ethernet cabling. Two of them have been standardized by IEEE 802.3. Since only two of the four pairs are needed for 10BASE-T or 100BASE-TX, power may be transmitted on the unused conductors of a cable. In the IEEE standards, this is referred to as Alternative B. Power may also be transmitted on the data conductors by applying a common-mode voltage to each pair. Because twisted-pair Ethernet uses differential signalling, this does not interfere with data transmission. The common mode voltage is easily extracted using the center tap of the standard Ethernet pulse transformer. This is similar to the phantom power technique commonly used for powering audio microphones. In the IEEE standards, this is referred to as Alternative A.In addition to standardizing existing practice for spare-pair and common-mode data pair power transmission, the IEEE PoE standards provide for signalling between the power sourcing equipment (PSE) and powered device (PD). This signaling allows the presence of a conformant device to be detected by the power source, and allows the device and source to negotiate the amount of power required or available. Up to a 25.5 watts is available for a device.