• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
supervisión de la temperatura en los bobinados y estator en un
supervisión de la temperatura en los bobinados y estator en un

... quede inservible, para prevenir este problema se utilizan sensores de temperatura que nos permiten tomar lecturas de los bobinados y estátor del generador, gracias a estas lecturas de temperatura podemos controlar esta variable, planear mantenimientos y prevenir daños en la maquina. En este document ...
TDC3000X Galvanic Isolation/Intrinsic Safety Field Termination
TDC3000X Galvanic Isolation/Intrinsic Safety Field Termination

... hazardous areas. The field wiring to the hazardous area is terminated to a removable connector on top of each isolator. Each isolator plugs onto the FTA. The connection between the FTA and the isolator is a “safe” connection because the IS interface is performed within the isolator. As a result, the ...
64-Position OTP Digital Potentiometer AD5171  FEATURES
64-Position OTP Digital Potentiometer AD5171 FEATURES

... This software application effectively replaces the need for external I2C controllers or host processors and, therefore, significantly reduces the development time of the users. An AD5171 evaluation kit includes the software, connector, and cable that can be converted for factory programming applicat ...
A Scalable Fault-Tolerant Layer 2 Data Center Network Fabric
A Scalable Fault-Tolerant Layer 2 Data Center Network Fabric

... to all switches. On the efficiency side, the broadcast overhead of such protocols would likely require configuring the equivalent of routing areas [5], contrary to R2. Hence, the current assumption is that the vision of a unified plug-and-play large-scale network fabric is unachievable, leaving data ...
uBR 10000 Series High-End Broadband Router
uBR 10000 Series High-End Broadband Router

... access for multiple ISPs via Policy-Based Routing • PBR works well in small to medium scale implementations • Managed access via VPNs using MPLS will be supported in February 2001 • MPLS-VPN provides a scalable, robust solution that protects the operator’s network www.cisco.com ...
XR50 Transmitter Pre-installation Manual
XR50 Transmitter Pre-installation Manual

... The RF connection to the transmitter output can be a serious safety hazard. Connect a 50 Ω test load during installation and commissioning. It is recommended that a switch be used to automatically connect the transmitter to the antenna system without human contact with the transmitting conductors. ...
MAX14970 Ruggedized 6Gbps SATA Redriver with High ESD and Extended Temperature Operation
MAX14970 Ruggedized 6Gbps SATA Redriver with High ESD and Extended Temperature Operation

... (gold standard) compliant and can also be pin configured for SATA specification version 2.6 (gold standard) compliance. The device features hardware SATA-drive cable detection that automatically places the device into a standby mode that consumes less than 20µA (typ) standby current when no drive is ...
Introduction - College of William and Mary
Introduction - College of William and Mary

... transient over-voltages. Surge protectors are generally priced between $20$170, depending on the level of surge suppression the unit can provide and the time it takes for the unit to react to a surge. Surge control is important because even small surges or spikes can eventually destroy or affect the ...
Samsung Refrigeration Familiarization
Samsung Refrigeration Familiarization

... Fahrenheit, the condenser fan will begin operation with the compressor. Between 61 and 65 degrees, the condenser fan energizes five minutes after the compressor energizes. Below 60 degrees, the condenser fan will not operate. This function is used to promote good oil distribution within the compress ...
GA-H61M-DS2
GA-H61M-DS2

... The motherboard contains numerous delicate electronic circuits and components which can become damaged as a result of electrostatic discharge (ESD). Prior to installation, carefully read the user's manual and follow these procedures: •• Prior to installation, do not remove or break motherboard S/N ( ...
VL-9542-AD Owner`s Manual
VL-9542-AD Owner`s Manual

... 6. Do not exceed maximum load of 600 watts. Z-Wave Device Network Installation Instructions for RF Master Dimmer Only: 1. This product may be added to a new or existing Z-Wave network. The device has a blue LED, which will blink when the device is not included in a Z-Wave network. The LED stop ...
ISL12025 Datasheet
ISL12025 Datasheet

... SDA is a bidirectional pin used to transfer data into and out of the device. It has an open drain output and may be wire ORed with other open drain or open collector outputs. The input buffer is always active (not gated). ...
ENG- FM FM1 FM2 Keeping Ovens Operating Manual
ENG- FM FM1 FM2 Keeping Ovens Operating Manual

... doing the ON/OFF symmetrical adjustment according to the temperatures and times set up in advance: Oven-environment 120°C with safety control on the heating elements at 470°C. ...
GEK-98000B-P Power/Vac Electrically Operated 15kV Ground
GEK-98000B-P Power/Vac Electrically Operated 15kV Ground

... The equipment described in this document may contain high voltages and currents which can cause serious injury or death. The equipment is designed for use, installation, and maintenance by knowledgeable users of such equipment having experience and training in the field of high voltage electricity. ...
Easy8051 v6 Manual
Easy8051 v6 Manual

Transformer Testing Experience by LVI/FRA Methods. Short
Transformer Testing Experience by LVI/FRA Methods. Short

... range from about 25 MVA to over 666 MVA and in voltage range from 110 kV to 750 kV were tested at short-circuit at Togliatty Power Testing Laboratory, Russia, during 19831995. The application of LVI method and measurement of inductive reactance deviation allowed detecting a twisting of low-voltage w ...
product catalog - ASSA ABLOY Door Security Solutions
product catalog - ASSA ABLOY Door Security Solutions

Structured Cabling System (SCS)
Structured Cabling System (SCS)

... ISO/IEC documents can also be used to provide the same standardized cabling architecture for the BMS devices, systems, and applications. The cabling and cable-delivery methods can be designed for all the services with the telecommunications closet (TC) as the terminating point for horizontal cables. ...
V2x Series Encoder Hardware Manual V21, V22, V23, V24
V2x Series Encoder Hardware Manual V21, V22, V23, V24

... Disconnect this video product from the power supply immediately and refer servicing to qualified service personnel under the following conditions. 1) When the power-supply cord or plug is damaged 2) If liquid has been spilled, or objects have fallen into the video product. 3) If the inner parts of v ...
On-Line Technical Training Course
On-Line Technical Training Course

Eaton 9E
Eaton 9E

... The terminal block on the back of the UPS also implements the R.E.P.O. (Remote Emergency Power Off) function that can be used to shut off the UPS remotely in case of an emergency. For installation, connect to the device's normally open contact . In case of an emergency, if the stop device is used, t ...
Product manual MICRO-0.25/0.3/0.3HV-I-OUTD-US-208/240 ABB solar inverters
Product manual MICRO-0.25/0.3/0.3HV-I-OUTD-US-208/240 ABB solar inverters

replacing batteries
replacing batteries

... The switch should be connected to a normally open switch contact. External voltage is not required; the switch is driven by 12V internal supply. In closed condition, 2mA of current are drawn The EPO switch is internally powered by the UPS for use with non-powered switch circuit breakers. The EPO cir ...
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)

... transistors are used for each cluster. The width of TTS is dependent on maximum delay of the gate, which is very less compared to the worst delay in the larger CMOS circuits. The unbalanced gate delays and delay differences of the input signals will not affect the Minimal Transient Time Slot (MTTS). ...
CFE Generator Protection Guidelines for Setting 40 and 64G
CFE Generator Protection Guidelines for Setting 40 and 64G

< 1 ... 44 45 46 47 48 49 50 51 52 ... 576 >

Power over Ethernet



Power over Ethernet or PoE describes any of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras. Unlike standards such as Universal Serial Bus which also power devices over the data cables, PoE allows long cable lengths. Power may be carried on the same conductors as the data, or it may be carried on dedicated conductors in the same cable.There are several common techniques for transmitting power over Ethernet cabling. Two of them have been standardized by IEEE 802.3. Since only two of the four pairs are needed for 10BASE-T or 100BASE-TX, power may be transmitted on the unused conductors of a cable. In the IEEE standards, this is referred to as Alternative B. Power may also be transmitted on the data conductors by applying a common-mode voltage to each pair. Because twisted-pair Ethernet uses differential signalling, this does not interfere with data transmission. The common mode voltage is easily extracted using the center tap of the standard Ethernet pulse transformer. This is similar to the phantom power technique commonly used for powering audio microphones. In the IEEE standards, this is referred to as Alternative A.In addition to standardizing existing practice for spare-pair and common-mode data pair power transmission, the IEEE PoE standards provide for signalling between the power sourcing equipment (PSE) and powered device (PD). This signaling allows the presence of a conformant device to be detected by the power source, and allows the device and source to negotiate the amount of power required or available. Up to a 25.5 watts is available for a device.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report