• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
scanCONTROL 2700
scanCONTROL 2700

Large 2 digit BCD input 1/8 DIN display - Model BCD-2
Large 2 digit BCD input 1/8 DIN display - Model BCD-2

DAC Presentation kit - University of Toronto
DAC Presentation kit - University of Toronto

... – Will be leaking power for long periods of time ...
Installation Guide
Installation Guide

... MALE ...
2 Easily completed these tasks!
2 Easily completed these tasks!

... You need to have phone conversations transmitted over the existing data net using VOIP. •Use the phone's ports to daisy chain the PCs to the rest of the net. •Do not use the regular power outlets to power phones. •Reduce the packet delay as much as possible. **This was probably the most confusing q ...
10 GigaBit Span Regeneration Tap with SFP Monitor Ports
10 GigaBit Span Regeneration Tap with SFP Monitor Ports

... still sees all full-duplex traffic as if it were inline, including Layer 1 and Layer 2 errors. For extra uptime protection, Net Optics Taps offer redundant power connections. Should the primary power source fail, the Tap automatically switches to the backup power source. Power LEDs on the front of t ...
iBusway for Data Center An innovative rack power distribution ready
iBusway for Data Center An innovative rack power distribution ready

... ● Up-stream support: architecture design (software) ● Operational service: commissioning ● Tested and warranty by Schneider Electric ...
Catoms: Moving Robots Without Moving Parts
Catoms: Moving Robots Without Moving Parts

... communicate, and obtain power. ...
flexible ac transmission systems
flexible ac transmission systems

... cases, overlooked. The factory is built but the grid is often found to be weak or even insufficient. The result is unsatisfactory plant performance as well as added "pollution" to the grid that spreads and affects other industries connected to it. In such cases, FACTS can confine or neutralize elect ...
MIG Welder Lincoln CV305
MIG Welder Lincoln CV305

... materials, you won’t find a more reliable power source than the CV-305. This well-engineered CV unit features two inductance connections. Lincoln’s Twist-Mate® output connectors make it easy to choose the right inductance for your application. ...
32910-Propeller-Activity-Board-Guide-v1.0.pdf
32910-Propeller-Activity-Board-Guide-v1.0.pdf

... The USB port is used:  to load programs from your computer into the Propeller microcontroller  to provide serial-over-USB communication with a terminal program on your computer.  to supply 5 V power to the Propeller Activity Board from your computer’s USB port. For power, the USB Port is input cu ...
Accurate Measurement of the Air-Core Inductance of Iron
Accurate Measurement of the Air-Core Inductance of Iron

... the required power is considerably lower than that of the conventional open-circuit test. Each time the transformer is excited with the rectifier, it goes curve. into deep saturation on the positive side of the Therefore, the result is accurate with any remnant flux, and the ...
for Low-Voltage High
for Low-Voltage High

... supply voltage. It also slows down the circuit operation speed sipificantly. Therefore. it is the challenge to retain high speed peifonnance under low-voltage. particularly when the power supply voltage approaches the threshold voltage. The complementary pass-transistor logic (CPL) as shown in Fig. ...
AS Interface gateway VBG MOD K20 D 1
AS Interface gateway VBG MOD K20 D 1

用 户 手 册 - Global Sources
用 户 手 册 - Global Sources

... instructions carefully before connecting, operating or adjusting this product. Please keep this manual for future reference. The products are designed to make your A/V device use more convenient, comfortable, productive and cost-efficient. This product will let the user experience of transmitting th ...
Megger® Hand-Held TDR / Cable Length Meter Megger® Hand
Megger® Hand-Held TDR / Cable Length Meter Megger® Hand

... Megger® Hand-Held TDR / Cable Length Meter ...
AC Main Panel Installation - Fondriest Environmental, Inc.
AC Main Panel Installation - Fondriest Environmental, Inc.

... Do not confuse the neutral current carrying wires (sometimes called ground) with the green normally non-current carrying wires (sometimes called grounding). These two wires must be connected only at the source of power, nowhere else. If the feed wires are from the shore power inlet or the electrical ...
IM-103 Rebuild Kit
IM-103 Rebuild Kit

... To replace a part, it is better to cut it from the circuit then gently remove the remaining leads using a low wattage soldering tool. Be careful not to destroy the terminal board by overheating the individual terminal contacts. If these get too hot, they can fall out of the terminal board. When repl ...
UPFC ICREDG_English-1-2
UPFC ICREDG_English-1-2

... The series converter executes the main function of the UPFC by injecting a voltage, with controllable magnitude and phase angle, in series with the transmission line. It is controlled to provide concurrent active and reactive series compensation without an external energy source. By means of the ser ...
Installation Manual
Installation Manual

Kerite Cable Services
Kerite Cable Services

... For over 25 years Kerite Cable Services has provided HV cable solutions to satisfied clients in the electric utilities industry. These installations range in size from a few hundred feet, within congested substations, to several miles of transmission circuits. A substation turnkey package from KCS p ...
Common Mode Noise The Often Neglected Tenth Power Problem
Common Mode Noise The Often Neglected Tenth Power Problem

... Computers and other electronic equipment play a key role in our lives. Everything from business to our personal enjoyment is addressed by these devices. As electronic equipment becomes more and more a part of our daily lives, the need for clean, quality, power to keep them operating at peak performa ...
Team 955 Electrical Certification
Team 955 Electrical Certification

... • 2 – 20 VDC input • 5V 0.25A supply for sensors • Standard 3 pin interface • Interfaces with NI 9201 The Analog Breakout Module is used to wire analog sensors to the cRIO NI 9201 module and to monitor the battery voltage ...
AZ044319323
AZ044319323

HIPERLAN: HIgh Performance Radio Local Area Networks
HIPERLAN: HIgh Performance Radio Local Area Networks

< 1 ... 458 459 460 461 462 463 464 465 466 ... 576 >

Power over Ethernet



Power over Ethernet or PoE describes any of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras. Unlike standards such as Universal Serial Bus which also power devices over the data cables, PoE allows long cable lengths. Power may be carried on the same conductors as the data, or it may be carried on dedicated conductors in the same cable.There are several common techniques for transmitting power over Ethernet cabling. Two of them have been standardized by IEEE 802.3. Since only two of the four pairs are needed for 10BASE-T or 100BASE-TX, power may be transmitted on the unused conductors of a cable. In the IEEE standards, this is referred to as Alternative B. Power may also be transmitted on the data conductors by applying a common-mode voltage to each pair. Because twisted-pair Ethernet uses differential signalling, this does not interfere with data transmission. The common mode voltage is easily extracted using the center tap of the standard Ethernet pulse transformer. This is similar to the phantom power technique commonly used for powering audio microphones. In the IEEE standards, this is referred to as Alternative A.In addition to standardizing existing practice for spare-pair and common-mode data pair power transmission, the IEEE PoE standards provide for signalling between the power sourcing equipment (PSE) and powered device (PD). This signaling allows the presence of a conformant device to be detected by the power source, and allows the device and source to negotiate the amount of power required or available. Up to a 25.5 watts is available for a device.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report