• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Ethernet Implementation
Ethernet Implementation

Verilog HDL Implementation of USB to Ethernet Converter
Verilog HDL Implementation of USB to Ethernet Converter

... transceiver of the sending station detects activity on both its receive and transmit pairs before it has completed transmitting, then it decides that a collision has occurred. On a coaxial system, a collision is detected when the DC signal level on the cable is the same or greater than the combined ...
Specialised Transformer Use for Active Power Flow Control in the
Specialised Transformer Use for Active Power Flow Control in the

... HVDC (High Voltage Direct Current) system was commercially first used 50 years ago. Since then a growing number of transmission systems have been constructed around the world. HVDC system has a number of properties that makes it different from AC transmission. The most important are: ƒ the two stati ...
SL150KV Rack Mount High Voltage Power Supply
SL150KV Rack Mount High Voltage Power Supply

... Spellman’s SL150kV rack mount high voltage power supply is designed for scientific and industrial OEM applications requiring 150kV at 1200 watts in a compact cable connected standard sized rack. Models are available in positive, negative or reversible polarity. The SL150kV is fully arc and short cir ...
LAB#3 - SIUE
LAB#3 - SIUE

... Transformers are probably the most universally used pieces of equipment in the electrical industry. They range in size from miniature units in transistor radios to huge units, weighing tons, used in central power distributing stations. However, all transformers have the same basic properties, which ...
Experiment — 2
Experiment — 2

... understanding power engineering. The mathematical relationship among them can be represented by vectors or expressed using complex numbers, (where j is the imaginary unit). ...
App Note 509 - What is Regulation and Repeatability?
App Note 509 - What is Regulation and Repeatability?

Lecture 1
Lecture 1

Low Voltage System Configuration
Low Voltage System Configuration

... • Isolation: power supply outputs must be floating. Furthermore, since one set of plus and minus outputs supply current for up to 10 trays tray inputs are isolated from other trauys to avoid interference. • HV will be interfaced to STAR interlock system. • Remote control software will be based on EP ...
MAX2242 2.4GHz to 2.5GHz Linear Power Amplifier General Description Features
MAX2242 2.4GHz to 2.5GHz Linear Power Amplifier General Description Features

... DC current can be reduced by an external DAC to increase PAE while still maintaining sufficient ACPR performance. This is achieved by using external resistors connected to the BIAS pin to set the bias currents of the driver and output stages. The resistors are typically 8kΩ. Typically, a DAC voltage ...
Ecograph T, RSG35 - Endress+Hauser Portal
Ecograph T, RSG35 - Endress+Hauser Portal

... A USB 2.0 connection is available on a shielded USB A socket at the front of the device. A USB stick, for example, can be connected to this interface as a storage medium. An external keyboard or USB hub may also be connected. 1 x USB port type B (function) A USB 2.0 connection is available on a shie ...
unit2 - WCU Computer Science
unit2 - WCU Computer Science

... Twisted, to avoid forming an antenna: reduces interference • Two major kinds – Cat 3 (1988 and earlier) • four pairs: (allows four telephone lines) ...
abstract - Wine Yard Technologies
abstract - Wine Yard Technologies

... ZigBee is the name of a specification for a suite of high level communication protocols using small, low-power digital radios based on the IEEE 802.15.4 standard for wireless personal area networks (WPANs), such as wireless headphones connecting with cell phones via short range radio. The technology ...
I56-3326 MIX-M502MAPA
I56-3326 MIX-M502MAPA

... The MIX-M502MAPA Interface Module is intended for use in intelligent, two-wire systems, where the individual address of each module is selected using the built-in rotary decade switches. This module allows intelligent panels to interface and monitor two-wire conventional smoke detectors. It transmit ...
Eaton's New J-Hook Color ID Products,News Release 3/11/14 Read more
Eaton's New J-Hook Color ID Products,News Release 3/11/14 Read more

Ethernet
Ethernet

... statistics for display to LAN administrators  100BaseT does not use Manchester encoding; it uses 4B5B for better coding efficiency  100BaseT usually uses category-5 twisted pair (a high-quality twisted pair of wires with many twists) ...
Giga-tronics white paper - RF/Microwave instrumentation amplifiers
Giga-tronics white paper - RF/Microwave instrumentation amplifiers

... performance. Solid-state amplifiers, on the other hand, have power ratings defined by their one or two dB gain compression point and can be operated at or near their rated one dB compression level to achieve linear performance. This means, for example, that a solid-state amplifier rated at 10 W P1dB ...
Signal Integrity for Vacuum Processing Systems
Signal Integrity for Vacuum Processing Systems

... Successful operation of power supplies and instrumentation in vacuum processing systems requires detailed attention to signal integrity. This paper introduces techniques involving signal grounding, shielding, coaxial cables, twisted pair cables, and quad cables, as well as methods for preventing ele ...
Getting Connected (Chapter 2 Part 3) Networking CS 3470, Section 1
Getting Connected (Chapter 2 Part 3) Networking CS 3470, Section 1

Project 2007-09 - Generator Verification
Project 2007-09 - Generator Verification

... then the next verification shall be by another staged test, not operational data: 2.1. Verify Real Power capability and Reactive Power capability over-excited (lagging) of all applicable Facilities at the applicable Facilities’ normal (not emergency) expected maximum Real Power output at the time of ...
• 100 - 240 Vac nominal input range • Overvoltage and short circuit
• 100 - 240 Vac nominal input range • Overvoltage and short circuit

... Condor DC Power Supplies Inc. 2311 Statham Parkway, Oxnard CA, 93033, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 Email: [email protected] G2T60 Rev C 7/27/05. Data Sheet © 2005 Condor DC Power Supplies Inc. The information and specifications contained in this data sheet are believed to be correc ...
LECTURE 10
LECTURE 10

... Has multiple antennas at each end of the channel – provides spatial diversity OFDM part about the same as 802.11a,g – uses 64QAM with 5/6 FEC rate Combines 2 of the 20MHz 802.11a,g channels to achieve higher data rates ...
Power Flow Enhancement of 220 KV
Power Flow Enhancement of 220 KV

... which three-phase circuits are represented by single lines. Transmission refers to the huge transfer of power by high voltage links between central generation and load centers. Distribution describes the dispatch of that power to the consumers by lower voltage networks [2] and [3]. In power system, ...
MAXIM INTEGRATED PRODUCTS
MAXIM INTEGRATED PRODUCTS

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... verify the functionality following which, synthesis and design implementation is carried out. Keywords:Power, Clock Gating, Intelligent Clock Gating,Dcg,Fpga,Xilinx ...
< 1 ... 400 401 402 403 404 405 406 407 408 ... 576 >

Power over Ethernet



Power over Ethernet or PoE describes any of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras. Unlike standards such as Universal Serial Bus which also power devices over the data cables, PoE allows long cable lengths. Power may be carried on the same conductors as the data, or it may be carried on dedicated conductors in the same cable.There are several common techniques for transmitting power over Ethernet cabling. Two of them have been standardized by IEEE 802.3. Since only two of the four pairs are needed for 10BASE-T or 100BASE-TX, power may be transmitted on the unused conductors of a cable. In the IEEE standards, this is referred to as Alternative B. Power may also be transmitted on the data conductors by applying a common-mode voltage to each pair. Because twisted-pair Ethernet uses differential signalling, this does not interfere with data transmission. The common mode voltage is easily extracted using the center tap of the standard Ethernet pulse transformer. This is similar to the phantom power technique commonly used for powering audio microphones. In the IEEE standards, this is referred to as Alternative A.In addition to standardizing existing practice for spare-pair and common-mode data pair power transmission, the IEEE PoE standards provide for signalling between the power sourcing equipment (PSE) and powered device (PD). This signaling allows the presence of a conformant device to be detected by the power source, and allows the device and source to negotiate the amount of power required or available. Up to a 25.5 watts is available for a device.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report