• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Selection, installation and assembly of surge protective devices
Selection, installation and assembly of surge protective devices

Figure 1.1 A telephone system.
Figure 1.1 A telephone system.

ElEctricity
ElEctricity

Electrical System Bonding and Grounding
Electrical System Bonding and Grounding

lecture1425873259
lecture1425873259

NE02 Brochure
NE02 Brochure

horstmann gmbh
horstmann gmbh

ITE-5HK250-MAG-VAC, 1200A, 2000A Medium
ITE-5HK250-MAG-VAC, 1200A, 2000A Medium

Residual Current Protective Devices / Arc Fault Detection Devices SENTRON
Residual Current Protective Devices / Arc Fault Detection Devices SENTRON

Protective Relay Application Guide
Protective Relay Application Guide

XRI1-IE - Combined time overcurrent and earth current relay
XRI1-IE - Combined time overcurrent and earth current relay

gfci / elci / egfpd
gfci / elci / egfpd

Leakage Current Reduction in CMOS VLSI Circuits by Input Vector
Leakage Current Reduction in CMOS VLSI Circuits by Input Vector

mira`s guide to
mira`s guide to

CAT L-200 24 Technical Information pages 783
CAT L-200 24 Technical Information pages 783

Powersub™ Vacuum Substation Circuit Breaker
Powersubâ„¢ Vacuum Substation Circuit Breaker

Hospital Isolated Power Systems
Hospital Isolated Power Systems

Parts List for Lab 2 - Electrical and Computer Engineering
Parts List for Lab 2 - Electrical and Computer Engineering

Slide 1
Slide 1

Electrical energy
Electrical energy

Electrical energy
Electrical energy

Basics of Load Centers
Basics of Load Centers

AC-DC sensitive residual current devices (Type B RCDs)
AC-DC sensitive residual current devices (Type B RCDs)

the inequality of circuit breaker standards - CBI
the inequality of circuit breaker standards - CBI

AGS General Science Chapt 8
AGS General Science Chapt 8

< 1 2 3 4 5 6 7 8 ... 27 >

Residual-current device



A residual-current device (RCD), or residual-current circuit breaker (RCCB), is a device to quickly disconnect current to prevent serious harm from an ongoing electric shock. Injury may still occur in some cases, for example if a person falls after receiving a shock. In the United States and Canada, the device is more commonly known as a ground fault circuit interrupter (GFCI), ground fault interrupter (GFI) or an appliance leakage current interrupter (ALCI). In the United Kingdom, these are better known by their initials RCD, and a combined RCD+MCB is known as a RCBO (residual-current circuit breaker with overcurrent protection). In Australia, they are sometimes known as safety switches or a RCD. An earth leakage circuit breaker (ELCB) may be a residual-current device, although an older type of voltage-operated earth leakage circuit breaker also exists.These electrical wiring devices disconnect a circuit when it detects that the electric current is not balanced between the energized (line) conductor(s) and the return (neutral) conductor. In normal circumstances, these two wires are expected to carry matching currents, and any difference usually indicates that a short circuit or other electrical anomaly is present. Even a small leakage current can mean a risk of harm or death due to electric shock if the leaking electric current passes through a human; a current of around 30 mA (0.030 amperes) is potentially sufficient to cause cardiac arrest or serious harm if it persists for more than a small fraction of a second. RCCBs are designed to disconnect the conducting wires quickly enough to prevent serious injury from such shocks. (This is commonly described as the RCD being ""tripped"".) A RCD does not provide protection against unexpected or dangerously high current when current is flowing in the usual wires in the circuit, therefore it cannot replace a fuse or protect against overheating or fire risk due to overcurrent (overload) or short circuits if the fault does not lead to current leakage. Therefore RCDs are often used or integrated as a single product along with some kind of circuit breaker, such as a fuse or miniature circuit breaker (MCB), which adds protection in the event of excessive current in the circuit. RCDs also cannot detect the situation where a human accidentally touches both conductors at the same time, since the flow of current through an expected device, an unexpected route, or a human, are indistinguishable if the current returns through the expected conductor.RCDs are usually testable and resettable devices. Commonly they include a button that when pressed, safely creates a small leakage condition, and a switch that reconnects the conductors when a fault condition has been cleared. Depending upon their design, some RCDs disconnect both the energized and return conductors upon a fault, while others only disconnect the energized conductor and rely upon the return conductor being at ground (earth) potential. The former are commonly known as ""double-pole"" designs; the latter as ""single-pole"" designs. If the fault has left the return wire ""floating"" or not at its expected ground potential for any reason, then a single-pole RCD will leave this conductor still connected to the circuit when it detects the fault.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report