• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
The difference between voltage and potential difference
The difference between voltage and potential difference

...  conventional circuit analysis without time-varying fields → Ohm law and Kirchhoff voltage law  time-harmonic electromagnetic field → Ohm law and Kirchhoff voltage law extend with Faraday law  the voltmeter readings are path dependent  the measured voltage depends on the rate of change of magnet ...
Fuses – Introductory Information
Fuses – Introductory Information

... There are many additional requirements, which cannot be addressed in detail here. Hence, only recommendations will be provided on what fuse type would be suitable for a given application (soldering processes such as infrared/wave soldering of surface mount components or wave soldering of wired comp ...
Interactive Notes
Interactive Notes

MAX14606/MAX14607 Overvoltage Protectors with Reverse Bias Blocking General Description
MAX14606/MAX14607 Overvoltage Protectors with Reverse Bias Blocking General Description

... overvoltage threshold, the internal FET is turned off to prevent damage to the protected components. The devices automatically choose the accurate internal trip thresholds. The internal OVLO are preset to typical 5.87V (MAX14606) or 6.8V (MAX14607). The MAX14606/MAX14607 feature reverse bias blockin ...
Inground Spa Equipment Installation Instructions
Inground Spa Equipment Installation Instructions

Application Notes Ohm’s Law
Application Notes Ohm’s Law

... Note 2: The rating of control apparatus in general is expressed in volts, amperes, horsepower or kilowatts as may be appropriate, except that resistors are rated in ohms, amperes and class of service.* Reactor: A device used for introducing reactance into a circuit for purposes such as motor startin ...
- Connect Innovate UK
- Connect Innovate UK

... - grounding is a complex issue and there are many different approaches to designing grounding in an electrical power distribution system: depending on factors such as the actual voltages involved and the general system lay-out, DC power grids may be ungrounded, high-resistance grounded, or low-resis ...
XRI1-IE - Combined time overcurrent and earth current relay
XRI1-IE - Combined time overcurrent and earth current relay

Impedance cardiography (ICG) is a non-invasive method to - IITB-EE
Impedance cardiography (ICG) is a non-invasive method to - IITB-EE

... cardiac output by sensing the variation in thoracic impedance during the cardiac cycle [4]-[10]. The bioimpedance is generally measured by passing an alternating current through a pair of surface electrodes (spot or band electrodes). The voltage resulting across the body segment, sensed using the sa ...
Integrated circuit including logic array with distributed ground
Integrated circuit including logic array with distributed ground

... unwanted switching of the FET to occur. For example, it is common for the FET’s in a microprocessor to be 25 either side as represented by blocks 22 and 23. Output drivers are represented by blocks 25 and 26. The ran organized into a programmable logic array (PLA), hav dom logic circuits common to s ...
Bonding and Grounding AMP NETCONNECT
Bonding and Grounding AMP NETCONNECT

A 0.9V 150MHz 10mW 4mm2 2-D Discrete Cosine Transform Core
A 0.9V 150MHz 10mW 4mm2 2-D Discrete Cosine Transform Core

... Kako, Masaaki Kinugawa, Masakazu Kakumu, Takayasu Sakurai Toshiba Corp., Kawasaki, Japan This two-dimensional 8x8 discrete cosine transform (DCT) core processor for portable multimedia equipment with HDTV-resolution in a 0.3µm CMOS triple-well double-metal technology operates at 150MHz from a 0.9V p ...
Distance Protection for Half Wavelength Transmission Lines
Distance Protection for Half Wavelength Transmission Lines

... an alternating current (AC link) option with some particular characteristics might be the most economical one, having much less dependence on the Power Electronics technology. In the 1960s [1]-[2], the first studies were done showing that the AC line has an interesting behavior in terms of voltage, ...
EST 2043 Answers - 18 September 2010 PDF, 111 KB
EST 2043 Answers - 18 September 2010 PDF, 111 KB

... automatically disconnected if the earth to the appliance is broken or disconnected. ...
High-Voltage Signal Conditioning for Low
High-Voltage Signal Conditioning for Low

7 Practical Aspects of Installation Design
7 Practical Aspects of Installation Design

Operating instructions K3G175RC0503 - ebm
Operating instructions K3G175RC0503 - ebm

File
File

Lab 7 - Circuits - Cabrillo College
Lab 7 - Circuits - Cabrillo College

... Every electrical circuit must have at least one source (which supplies electrical energy to the circuit) and at least one load (which removes electrical energy from the circuit). When two or more loads are connected to a single source, they may be connected in series (end-to-end), in parallel (side- ...
High Current Power Supply, Cat. No. BT406
High Current Power Supply, Cat. No. BT406

... BT Lab Systems High Current Power Supply has been tested and found to comply with the limits for the CE regulation. Also, it is RoHS compliant to deliver confident product which meets the environmental directive. These limits are designed to provide reasonable protection against harmful interference ...
ELITE 15 PF OWNER`S MANUAL
ELITE 15 PF OWNER`S MANUAL

SIPROTEC 4 7SJ63 Multifunction Protection Relay
SIPROTEC 4 7SJ63 Multifunction Protection Relay

... When the high-impedance measurement principle is applied, all current transformers in the protected area are connected in parallel and operated on one common resistor of relatively high R whose voltage is measured (see Fig. 5/115). In the case of 7SJ6 units, the voltage is measured by detecting the ...
Practical Approaches to Reducing Transient - IEEE
Practical Approaches to Reducing Transient - IEEE

... operationally. It is well understood that restrike can result in very high T factors. As stated in [1], if restriking of the switching device is included, then the resulting overvoltages are essentially the same as those of reclosing into a trapped charge. The only difference is the probability of o ...
Capacitors for Power Factor Correction
Capacitors for Power Factor Correction

electrical safety general electrical safety
electrical safety general electrical safety

... fibrillation. This is not much current when you realize that a small power drill uses 30 times as much current as what will kill. At relatively high currents, death is certain if the shock is long enough. However, if the shock is short and the heart has not been damaged, a normal heartbeat may resum ...
< 1 ... 91 92 93 94 95 96 97 98 99 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report