• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
MAX4644 Full Data Sheet
MAX4644 Full Data Sheet

ELEC34 - aes journals
ELEC34 - aes journals

... and commercial installations. Such motors have extensive usage in consequence of their sturdy edifice, unpretentious installation, undemanding control strategies, and adaptability to various industrial applications. Furthermore, induction motors may plausibly be fed from an unswerving sinusoidal pow ...
Data Sheet
Data Sheet

... Ensure that the direction and position are correct when mounting the IC on the PCB. Incorrect mounting may result in damaging the IC. Avoid nearby pins being shorted to each other especially to ground, power supply and output pin. Inter-pin shorts could be due to many reasons such as metal particles ...
Three-Level Inverter-Based Shunt Active Power Filter in Three
Three-Level Inverter-Based Shunt Active Power Filter in Three

the inequality of circuit breaker standards - CBI
the inequality of circuit breaker standards - CBI

MN1919WEN MicroFlex
MN1919WEN MicroFlex

... Unless otherwise specified, this drive is intended for installation in a suitable enclosure. The enclosure must protect the drive from exposure to excessive or corrosive moisture, dust and dirt or abnormal ambient temperatures. The exact operating specifications are found in section 8 of this manual ...
LTC5542 - 1.6GHz to 2.7GHz High Dynamic Range Downconverting Mixer.
LTC5542 - 1.6GHz to 2.7GHz High Dynamic Range Downconverting Mixer.

... generated bias voltage of 1.2V. It must be DC-isolated from ground and VCC. GND (Pins 4, 10, 12, 13, 17, Exposed Pad Pin 21): Ground. These pins must be soldered to the RF ground plane on the circuit board. The exposed pad metal of the package provides both electrical contact to ground and good ther ...
doc - Iowa State University
doc - Iowa State University

Phys11U_Unit 5_Ch13_transmittal_July12
Phys11U_Unit 5_Ch13_transmittal_July12

... Electromagnetic induction is also used to detect metals. Metal detectors use a coil that generates a rapidly changing magnetic field. This magnetic field will induce a current in any metal near it. The induced electric current in the detected metal will also produce an induced magnetic field of its ...
3 Ohm`s Law - Skills Commons
3 Ohm`s Law - Skills Commons

... The current has been reduced to one half of the value of the previous equation, or 0.3 ampere. This demonstrates that the current is inversely proportional to the resistance. Doubling the value of the resistance of the load reduces circuit current value to one half of its former value. Ohm's Law als ...
2ch High Side Switch ICs for USB Devices and Memory Cards Datasheet
2ch High Side Switch ICs for USB Devices and Memory Cards Datasheet

... When excessive current flows due to output short-circuit or so, ringing occurs because of inductance between power source lines to IC, and may cause bad influences on IC operations. In order to avoid this case, connect a bypass capacitor across IN terminal and GND terminal of IC. 1μF or higher is re ...
2 - Electrical Contractor Network
2 - Electrical Contractor Network

Bates
Bates

... continuity between two points.  When checking for continuity, make sure the ohmmeter is set on the lowest ohms range.  If continuity exists between two points, the ohmmeter will read a very low resistance such as zero ohms.  If there is no continuity between two points, the ohmmeter will read inf ...
4.1 Main electrical characteristics
4.1 Main electrical characteristics

TCS-DL004-250-WH
TCS-DL004-250-WH

... The Bourns® TCS™ High-Speed Protector acts like a low value resistor during normal operation. As the Bourns® TCS™ HighSpeed Protector has no electrical connection to anything other than the signal line it protects, the capacitance to ground is purely dictated by the capacitance of the device to surr ...
2SP0115T Preliminary Description & Application Manual
2SP0115T Preliminary Description & Application Manual

Effective Drive Current in CMOS Inverters for Sub
Effective Drive Current in CMOS Inverters for Sub

MAX13202E/MAX13204E/MAX13206E/MAX13208E 2-/4-/6-/8-Channel, ±30kV ESD Protectors in µDFN General Description Features
MAX13202E/MAX13204E/MAX13206E/MAX13208E 2-/4-/6-/8-Channel, ±30kV ESD Protectors in µDFN General Description Features

... Proper circuit-board layout is critical to suppress ESDinduced line transients. The MAX13202E/MAX13204E/ MAX13206E/MAX13208E clamp to ±120V; however, with improper layout, the voltage spike at the device is much higher. A lead inductance of 10nH with a 45A current spike at a dv/dt of 1ns results in ...
Request for Bids_NE Starkville VCBs_2016-01-11
Request for Bids_NE Starkville VCBs_2016-01-11

MN201001EN/S201-20-1
MN201001EN/S201-20-1

... Eaton's Cooper Power series single-phase pad-mounted distribution transformers. Pad-mounted distribution transformers from Eaton's Cooper Power series are designed for installation on single-phase underground systems. All units are constructed for weather exposed mounting on a concrete pad with high ...
MWS Power Fitting - PF and FF
MWS Power Fitting - PF and FF

... 18AWG TFN while PF leads are 12AWG TFN. All leads come with pushwire connectors. ...
Mapping Document
Mapping Document

... not proposed because the quantity is not useful for fault analysis ...
MAX3202E/MAX3203E/MAX3204E/MAX3206E Low-Capacitance, 2/3/4/6-Channel, ±15kV ESD Protection Arrays for High-Speed Data Interfaces General Description
MAX3202E/MAX3203E/MAX3204E/MAX3206E Low-Capacitance, 2/3/4/6-Channel, ±15kV ESD Protection Arrays for High-Speed Data Interfaces General Description

... PROTECTED LINE NEGATIVE ESD ...
Powersub™ Vacuum Substation Circuit Breaker
Powersub™ Vacuum Substation Circuit Breaker

... • Turn OFF all power before working on or inside equipment. • Always use a properly rated voltage sensing device to confirm that power is off. • All maintenance must be performed by qualified personnel in accordance with local codes and under the following conditions: — The circuit breaker must be i ...
PS-A.3 Terms and definitions - Power Sources Manufacturers
PS-A.3 Terms and definitions - Power Sources Manufacturers

< 1 ... 51 52 53 54 55 56 57 58 59 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report