• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
AC DC Internet Articles Easy
AC DC Internet Articles Easy

Retrofit for Siemens GIS Type 8D1 / 8D2
Retrofit for Siemens GIS Type 8D1 / 8D2

... circuit breaker used at the beginning of the introduction to the market require very high maintenance. On the other hand, remaining GIS-components like disconnector, earthing switch, busbar, etc. need very low care and have a long service life. The Siemens retrofit solution with a modern SF6-self bl ...
Figure 12–4 - WordPress.com
Figure 12–4 - WordPress.com

fault location on subsea cable systems
fault location on subsea cable systems

INSTRUCTION - 2A/12V DC boxed power supply
INSTRUCTION - 2A/12V DC boxed power supply

Three Phase Fault Analysis with Auto Reset for Temporary
Three Phase Fault Analysis with Auto Reset for Temporary

200 W, Single Output Power Supply
200 W, Single Output Power Supply

AD4C212 - ssousa.com
AD4C212 - ssousa.com

Electricity and Magnetism
Electricity and Magnetism

... Georg Simon Ohm (1787-1854), a German physicist, discovered Ohm’s law in 1826. ...
Effects of Electric Current * Learning Outcomes
Effects of Electric Current * Learning Outcomes

Electricity guided notes
Electricity guided notes

... Conductors let electrons move ____________. Insulators do ________ let electrons move easily. A _________________________ has conductivity somewhere between an insulator and a conductor. Devices made of semi-conductors, notably _____________________, are essential components of most electronic circu ...
PolySwitch Device Enhances Overcurrent
PolySwitch Device Enhances Overcurrent

... thermally activated device, it resets automatically and resists nuisance tripping. Once a fault condition is removed and the PolySwitch device temperature drops, the device returns to a low-resistance value, restoring normal circuit operation. If a short duration event occurs—for example, inrush cur ...
Lecture #12 03/01/05
Lecture #12 03/01/05

... •In an emf source, going – to + gives a positive V, + to - is a negative V •Solve all equations You might end up with many equations, but I trust that you can solve simultaneous equations. ...
Features - Embedia
Features - Embedia

... Intelligence is distributed to each controller, allowing the system to scale to any size without the danger of a central point of failure. ...
Building a VLSI Neuron
Building a VLSI Neuron

Safety in electrical testing – service and repair HSE information sheet Introduction
Safety in electrical testing – service and repair HSE information sheet Introduction

... individual sleeves can be placed over conductors. This may be difficult where the conductor areas are small (connection size). In these cases, ensure that a safe system of work, incorporating the other relevant precautions listed below, is being followed. ■■ Where the dangerous conductors on the equ ...
ELECTRICITY
ELECTRICITY

... • Electric current that travels back and forth in a circuit. – Changes direction 60 times in a second!!! – Much more intense than Direct Current – Created by a generator (magnets inside) ...
LF 205-S
LF 205-S

... Rms voltage for AC insulation test, 50/60 Hz, 1 min Impulse withstand voltage 1.2/50 µs Partial discharge extinction voltage rms @ 10 pC ...
hmrp - Mirus International
hmrp - Mirus International

Advantages and Disadvantages of Different Types of Neutral
Advantages and Disadvantages of Different Types of Neutral

File
File

... ACTIVITY 63 Components with other functions   ...
CABLE FAULT PRE-LOCATOR MODEL- KM-CFPL
CABLE FAULT PRE-LOCATOR MODEL- KM-CFPL

... automatic Cable Fault Locator which adopts ARM, FPGA & Dot Matrix Color LCD display Technology. This tester combines both pulse ...
2006 Q9 - Loreto Balbriggan
2006 Q9 - Loreto Balbriggan

... What is the resistance of the filament of a light bulb, rated 40 W, when it is connected to the mains? Explain why the resistance of the bulb is different when it is not connected to the mains. ____________________________________________________ ...
Measuring Ground Resistance — The Fall of Potential Method
Measuring Ground Resistance — The Fall of Potential Method

... tend to seem impractical, and they would like to have something more cost-effective. Remember, a ground test is not being performed on a circuit in the conventional sense, where current is being neatly directed from point to point by human design. Rather, it is governed by nature, in the form of loc ...
WBPT Series - Panel Mount Isolation Transformers
WBPT Series - Panel Mount Isolation Transformers

< 1 ... 288 289 290 291 292 293 294 295 296 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report