• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Probing Further: Household electrical power
Probing Further: Household electrical power

Fault current reduction by SFCL in a distribution system with PV
Fault current reduction by SFCL in a distribution system with PV

ABB Template
ABB Template

... Because the open circuit voltage is limited by saturation of the core, the RMS value measured by a voltmeter may not appear to be dangerous. As the current cyclically passes through zero, the rate of change of flux at current zero is not limited by saturation, and is very high indeed. This induces e ...
Stray Voltage: Sources and Solutions
Stray Voltage: Sources and Solutions

Ch 34 Electric Current Summary
Ch 34 Electric Current Summary

Lecture 5
Lecture 5

... causing it to rotate and move a pointer across a calibrated scale. The deflection of the pointer is proportional to the current ...
Rectifier Circuit Current Ratios
Rectifier Circuit Current Ratios

... power diodes and SCRs requires ultra current-limiting short circuit fuses; semiconductor devices cannot withstand heavy short-circuit current. The circuits in which fuses are installed place certain requirements upon high speed fuses. These requirements are generally more stringent than the fuse req ...
2159
2159

... The Cooper Bussmann BSPD5BNCSI two-stage in-line surge arrester is for protecting coaxial cable-connected systems (such as video and camera systems) from potential damage. The BSPD5BNCSI shielded surge arrester is plugged into coaxial terminal equipment or connections. Common applications include pr ...
Recommended Practice for Establishing Ground Potential Rise (GPR)
Recommended Practice for Establishing Ground Potential Rise (GPR)

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... In transmission lines with a three-phase power source, there are ten types of faults that can occur. The faults in the order of decreasing frequency of occurrence are: three single-phase-to ground faults (1LGs), three phaseto-phase faults (2Ls), three double-phase-to-ground faults (2LGs), and a thre ...
isometer
isometer

... especially when factors such as production failure, repairs, device replacement or even unplanned service work are counted. Increasing availability - reducing costs The key objective of any system operator must be to recognise faults at an early stage and eliminate the cause in an efficient way. To ...
Transformer Notes
Transformer Notes

test 2 review
test 2 review

electric current - INFN-LNF
electric current - INFN-LNF

... experience a force when near other electrically charged matter.” Beyond plain definition, electric charge depends on electrons, which are the fundamental bricks of electromagnetism. The electron is a subatomic particle carrying a negative electric charge whose value is −1.602176487×10−19 Coulomb. ...
Name: Date:______ Hour:______ Assignment #______ Power and
Name: Date:______ Hour:______ Assignment #______ Power and

... Power and Energy Calculations Use the following formulas below to solve. ...
File
File

... The __ __ in the circuit is like a radiator. An electrical device uses electrical energy supplied by the circuit. Instead of a flow of water, electricity flows in an electrical circuit. The _______ are like pipes; they carry the electricity (called current) round the circuit. The electrical current ...
New Comparators Feature Micropower Operation Under All
New Comparators Feature Micropower Operation Under All

Chip Detects Shorts and Overloads, Measures Current
Chip Detects Shorts and Overloads, Measures Current

... Avago Technologies has produced a new device that can help designers of motor control circuits measure current and detect short circuits and overloads. The HCPL-788J chip galvanically isolates the motor-side and microcontroller/DSP side so you don't have to include an isolation amplifier or opto-iso ...
HAS 600-S
HAS 600-S

WIRE 1 = WIRE 2 = WIRE 3 - Bishopston Comprehensive School
WIRE 1 = WIRE 2 = WIRE 3 - Bishopston Comprehensive School

... The fuse is always connected in the live part of the circuit. This is because it is only then can we be sure there is no chance of electrocution. If the fuse were connected in the neutral part of the circuit then the live wire would still be active all the way up to the appliance (risky!) Fuses come ...
Conducted Emissions - IEEE Rock River Valley Section
Conducted Emissions - IEEE Rock River Valley Section

View - Toshiba America Electronic Components
View - Toshiba America Electronic Components

... etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or bodily injury (“Unintended Usage”). Unintended Usage include atomic energy contro ...
SAMPLE ELECTRICAL PI QUESTIONS 1. Why heat produce in AC
SAMPLE ELECTRICAL PI QUESTIONS 1. Why heat produce in AC

BASE Power Overview 2016
BASE Power Overview 2016

... Overvoltage Shut OFF with VCC > 26V ...
50A-3PH 3 Phase Current Injection System
50A-3PH 3 Phase Current Injection System

... the current outputs and an external voltage or current. The timing system is very flexible without compromising ease of use, allowing trip times, reset times and reclose times to be quickly measured to a high degree of accuracy. Two independently isolated contact inputs are provided, and the timing ...
< 1 ... 267 268 269 270 271 272 273 274 275 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.