• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
2015 Power transformers design and analysis with Flux SG CN67
2015 Power transformers design and analysis with Flux SG CN67

... components can model either wounded coils or conductors with Eddy currents and skin effects. A new model of coil conductor region with losses allows skin and proximity effects to be assessed in coils without representing each wire. This means fast solving and less memory requirement. Thanks to dedic ...
Series and parallel circuits
Series and parallel circuits

... Task 2 – Parallel circuits Parallel circuits have components connected in parallel with the power supply and components are connected in parallel with each other. If one of the lamps fails, the other will still work. The current has more than one path to take. The amount of current flowing is larger ...
Current Transformers
Current Transformers

Tranquell™ Series - GE Industrial Solutions
Tranquell™ Series - GE Industrial Solutions

Reliably Detect Faults In Circuit Breakers with
Reliably Detect Faults In Circuit Breakers with

... Circuit breakers are commonly used to manage the flow of electricity within a home or office but their reliable functionality is often taken for granted. Circuit breakers rely on making a solid electrical contact between the AC mains and the rest of the circuitry with the ability the open the circui ...
SPH3U - K-Moncrief
SPH3U - K-Moncrief

... person touching a live wire with their outstretched hand may literally not be able to let go of the wire due to the current's effect on the muscles. Currents from 0.03 to 0.07 amp will begin to impair the ability of the person to ...
higher tier revision questions
higher tier revision questions

Application of 60 Hz rated medium voltage vacuum circuit
Application of 60 Hz rated medium voltage vacuum circuit

... current rating, the rated value was primarily established by measuring the temperature rise of the current carrying components with the rated current applied. The stabilized temperature must have been less than or equal to the maximum values stated in the relevant test standard. The material propert ...
TPL-001-0.1
TPL-001-0.1

... d) A number of extreme contingencies that are listed under Category D and judged to be critical by the transmission planning entity(ies) will be selected for evaluation. It is not expected that all possible facility outages under each listed contingency of Category D will be evaluated. e) Normal cle ...
Experiment 19 Series and Parallel Resistances ∑
Experiment 19 Series and Parallel Resistances ∑

... 10. Adjust the dial on the power supply until the DMM reads approximately 1.0 volt. Record this voltage. Now measure the voltage difference across the 100Ω resistor and record this voltage. Do the same for the 200Ω and the 300Ω resistors. Are the values the same? 11. Measure current vs. potential as ...
In this proposed method we are test 36-bit input ISCAS
In this proposed method we are test 36-bit input ISCAS

... Over testing due to the application of two-patterns can-based tests was described. Over testing is related to the detection of delay faults under non-functional operation conditions. One of the reasons for these non-functional operation conditions is the following. When an arbitrary state is used as ...
ACADEMIC PHYSICS REVIEW: CIRCUITS
ACADEMIC PHYSICS REVIEW: CIRCUITS

... a. Explain why these two seemingly contradictory representations exist. ...
Electrical Hazards and Safety
Electrical Hazards and Safety

... Circuit breakers and Fuses: These protect wires from overheating and are found in the distribution panel box. When there is an overload, that is, too much current flowing, the fuses will blow or the circuit breakers will trip. Fuses and circuit breakers are rated so therefore at a particular current ...
File
File

ground loops in the av world
ground loops in the av world

Transformer Secondary Tap Conductors
Transformer Secondary Tap Conductors

... Thus, in most cases, the provisions of 240.21(C)(2), transformer secondary conductors not over 10 feet or 240.21(C)(6), transformer secondary conductors not over 25 feet must be met. Regardless of which rule is used, besides the tap conductor rules, short-circuit protection of the transformer second ...
Electricity jeopardy
Electricity jeopardy

... Neutron - neutral ...
Put that in the Form of a Question, Please!”
Put that in the Form of a Question, Please!”

... Neutron - neutral ...
Create PDF - HighFinesse
Create PDF - HighFinesse

Solutions: Chapter 8 Exercises 1. Excess electrons rubbed from your
Solutions: Chapter 8 Exercises 1. Excess electrons rubbed from your

... has its own current path. 45. The three circuits are equivalent. Each branch is individually connected to the battery. 46. Yes, there will be a decrease in brightness if too many lamps are connected in parallel because of the increased current that flows through the battery. Internal voltage drop in ...
- Electrotehnică, Electronică, Automatică (EEA)
- Electrotehnică, Electronică, Automatică (EEA)

Protection components
Protection components

... provide commonly 1N/O +1N/C output relay contact. Mors Smitt protection relays operate on an electromechanical magnetic circuit principle. Primary current or voltage create in the magnetic circuit a flux. A permanent magnet creates an opposite flux maintaining the contacts in rest position. As soon ...
Télécharger
Télécharger

... expect line protective relays to offer traveling-wave fault locating with ten-fold better accuracy. The SEL-T400L incorporates a single-ended traveling-wave fault-locating method, which calculates the fault location by analyzing only the local current traveling waves without the need for a communica ...
Group Motor Protection
Group Motor Protection

... Typically, group motor installations protected by one branch circuit OCPD and group switching are considered for cost savings. However, caution should be taken where a conductor is expected to be protected by an overcurrent protective device significantly greater than the conductor ampacity. The NEC ...
Inst. för teknik och naturvetenskap 2007-03-14 Dnr ITN 55/07
Inst. för teknik och naturvetenskap 2007-03-14 Dnr ITN 55/07

< 1 ... 253 254 255 256 257 258 259 260 261 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report