• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Teacher`s Guide - Discovery Education
Teacher`s Guide - Discovery Education

... experiment with this and see what they find out. Have students draw a diagram of a parallel circuit in their science journals or on a piece of paper. 12. After students have demonstrated a clear understanding of parallel and series circuits, ask them to provide examples of parallel and series circui ...
PUB-NP-279 Q. Describe Newfoundland Power’s protective relaying criteria (standard design
PUB-NP-279 Q. Describe Newfoundland Power’s protective relaying criteria (standard design

... entering an electrical node must exactly equal the amount of electricity leaving the node. For substation buses, if this rule fails because the electricity flow on transmission lines into the substation bus does not match the electricity flow through to the distribution feeders then it is assumed th ...
I 2
I 2

Standard Type Mini-molded chip LEDs
Standard Type Mini-molded chip LEDs

... The products listed in this document are designed to be used with ordinary electronic equipment or devices (such as audio visual equipment, office-automation equipment, communications devices, electrical appliances and electronic toys). Should you intend to use these products with equipment or devic ...
Transition of Magnetic Current Limiter to Superconducting Fault
Transition of Magnetic Current Limiter to Superconducting Fault

Energized Electrical Work Permit
Energized Electrical Work Permit

... (3) Results of Flash Hazard Analysis: Flash Protection Boundary: ____________ (Assumed or Calculated) Hazard/Risk Category __________ OR Calculated Flash Hazard at 18” ____________ (4) Necessary personal protective equipment to safely perform the assigned task: ___________________________ ...
OEM Powerpoint Template Mst.
OEM Powerpoint Template Mst.

... ● Min/max log of all real-time readings ● Interval logging, min/max/avg. of certain parameters. Interval length 1– 1440 minutes. (ex. min/max/avg of current every 5 minutes) ● Default logging loaded at factory, begins on power up Schneider Electric - Marketing – PowerLogic CM 3000 series Circuit Mon ...
Meaning of symbol
Meaning of symbol

... CAUTION! Please consult the operating instructions before using the device. In these operating instructions, failure to follow or carry out instructions preceded by this symbol may result in personal injury or damage to the device and the installations. ...
ELTC 101 - Muskegon Community College
ELTC 101 - Muskegon Community College

... Evaluate the operation of the loaded voltage divider. Design, construct and test measured results in comparison to calculations Describe how to troubleshoot and recognize: a. an open component b. a component value variation c. a short circuit in a series circuit Describe the difference between a ser ...
BP7A - L-Series IPM Interface Circuit Reference Design
BP7A - L-Series IPM Interface Circuit Reference Design

... A significant advantage provided by the L-Series IPM’s builtin gate drive and protection circuits is that the entire family outlined in Table 1 requires only two different interface circuit designs. The standard interface circuit consists of opto-couplers to transfer control signals and isolated pow ...
02025
02025

... Recall that it was mentioned that extrapolation methods were only valid if the arc between the contacts was in the diffuse mode. This would be true if the current being interrupted has a low value, such as switching levels or small faults. This is also true for higher fault levels if the contact str ...
2005 Code Changes
2005 Code Changes

... current rating. This facilitates the inspection and approval process. Inspectors need this information to ensure that 110.10 is met. The potential hazard exists where higher fault currents are available. It is now required that industrial control panels, industrial machinery electrical panels, certa ...
Amp Enable Outputs
Amp Enable Outputs

... the motor I-variable Ix25. All flag inputs must be shorted to the zero-volt reference voltage for the circuit, allowing current to flow through the LEDs in the opto-isolator, in order to be considered in a zero state. The voltage circuit can be configured in various ways utilizing PMAC PC jumpers E8 ...
#2093
#2093

... The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information th ...
Bias Point Calculations - CVL Wiki
Bias Point Calculations - CVL Wiki

... Right Click to end the process of placing the part Vdc. Control-R will rotate the part 90 degrees for each CNT-R. Control-F will flip the part about a vertical axis. ...
Bias Point Calculations: - CVL Wiki
Bias Point Calculations: - CVL Wiki

... Right Click to end the process of placing the part Vdc. Control-R will rotate the part 90 degrees for each CNT-R. Control-F will flip the part about a vertical axis. ...
Vocia® VO-4e Operation Manual
Vocia® VO-4e Operation Manual

... 14) Refer all servicing to qualified service personnel. Servicing is required when the product has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the product, the product has been exposed to rain or moisture, does not operat ...
stepping up electrical safety practices
stepping up electrical safety practices

... Ontario and defines and enforces safety standards through the Ontario Electrical Safety Code, Ontario Regulation 164/99. ...
Full Text - ISSN: 1545
Full Text - ISSN: 1545

14 Current and Voltage Measurements
14 Current and Voltage Measurements

... The magnetic field of the coil is proportional to the electric current The deflection angle is proportional to the magnetic field Hence, the deflection angle is proportional to the current The maximum current that can be measured depends on the full scale deflection (f.s.d) of the ammeter ...
XRP2524
XRP2524

... The XRP2524 is a dual channel integrated high-side power distribution switch optimized for self or bus-powered USB applications and it is compliant with the latest USB 3.0 specification. It accepts an input voltage between 2.7V and 6.5V allowing for operations from industry standard 3.3V and 5V powe ...
Electrical Safe Work Practice
Electrical Safe Work Practice

... • Installations of electric conductors and equipment within or on buildings or other structures, and on other premises such as yards, carnival, parking, and other lots, and industrial substations; ...
PS22A79  < Dual-In-Line Package Intelligent Power Module >
PS22A79 < Dual-In-Line Package Intelligent Power Module >

... 4 :R1, C4 of RC filter for preventing protection circuit malfunction is recommended to select tight tolerance, temp-compensated type. The time constant R1C4 should be set so that SC current is shut down within 2μs. (1.5μs~2μs is general value.) SC interrupting time might vary with the wiring pattern ...
TechTopics
TechTopics

PS22A79
PS22A79

... 4 :R1, C4 of RC filter for preventing protection circuit malfunction is recommended to select tight tolerance, temp-compensated type. The time constant R1C4 should be set so that SC current is shut down within 2μs. (1.5μs~2μs is general value.) SC interrupting time might vary with the wiring pattern ...
< 1 ... 199 200 201 202 203 204 205 206 207 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report