• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Lab 6 Series and Parallel Circuits - Lawrence Technological University
Lab 6 Series and Parallel Circuits - Lawrence Technological University

AC Power Distribution 6-9-10
AC Power Distribution 6-9-10

Calculating power factor
Calculating power factor

... Figure above. Negative power is fed back to the generator. It cannont be sold; though, it does waste power in the resistance of electric lines between load and generator. The parallel capacitor corrects this problem. Note that reduction of line losses applies to the lines from the generator to the p ...
manual - Zodiac
manual - Zodiac

Protect your Power!
Protect your Power!

INSTRUCTION MANUAL #102 SINGLE PHASE PAD MOUNT DISTRIBUTION TRANSFORMER
INSTRUCTION MANUAL #102 SINGLE PHASE PAD MOUNT DISTRIBUTION TRANSFORMER

Draft - NYU Steinhardt
Draft - NYU Steinhardt

... Electricity is electric energy. Electricity can be changed into light energy and heat energy. Electricity is dangerous if it is not used correctly. It can cause burns, shock, and death if it travels through‎a‎person’s‎body.‎‎An‎important‎safety‎ rule to follow is never touch anything electrical whil ...
Chapter 6: Single Phase Transformer
Chapter 6: Single Phase Transformer

... changing voltage and current levels in electric power systems. matching source and load impedances for maximum power transfer in electronic and control circuitry. electrical isolation (isolating one circuit from another or isolating dc while maintaining ac continuity between two circuits). ...
Chapter 24 Three-Phase Voltage Generation
Chapter 24 Three-Phase Voltage Generation

Safety Risk Assessment for Lab Electrical Equipment FORM BLANK
Safety Risk Assessment for Lab Electrical Equipment FORM BLANK

Electromagnetic compatibility of power converters
Electromagnetic compatibility of power converters

Electromagnetic compatibility of power converters
Electromagnetic compatibility of power converters

02 electric power
02 electric power

... The delta-wye connection is shown in figure 2-11. Note that for the given turns ratios of 1:1 that the magnitude of the phase-to-phase output voltage is equal to the magnitude of the phase-to-phase input voltage multiplied by √3 . The input and output voltages of 3Ø transformers and 3Ø banks of sing ...
Electric Service Requirements - Singing River Electric Power
Electric Service Requirements - Singing River Electric Power

... in lieu of a grounding electrode but may be used in conjunction with it. Connection Between Ground Wire and Grounding Electrode 1. The connection between the ground wire and electrode shall be easily accessible and shall not be covered by concrete or any other substance. 2. The ground clamp must be ...
document
document

... Motor circuits include motor control devices such as motor starters and contactors, together with overcurrent protection components such as overload relays, circuit breakers, and fuses are often assembled into motor control panels and motor control centers as well as individual enclosures. Motor con ...
NEMA Evaluating Water damaged Electrical Equipment
NEMA Evaluating Water damaged Electrical Equipment

... Motor circuits include motor control devices such as motor starters and contactors, together with overcurrent protection components such as overload relays, circuit breakers, and fuses are often assembled into motor control panels and motor control centers as well as individual enclosures. Motor con ...
Autotransformer 120/240V - 32A and 120/240 - 100A
Autotransformer 120/240V - 32A and 120/240 - 100A

... neutral, as shown in figure 1, any load unbalance is ‘absorbed’ by the Autotransformer. In case of a 30A supply, the load can be increased to 7,2kVA, and a 20A load unbalance will result in one leg supplying 40A, and the other leg 20A. The 20A difference will flow through the neutral and the winding ...
Chapter 4_Power Transformer
Chapter 4_Power Transformer

... Every transformer has a maximum output current that it can deliver at its standard output voltage. This VA rating (KVA or MVA for large power transformers) is dependent on the ambient temperature or cooling provided. Exceeding the VA rating will cause overheating of the core and windings and subsequ ...
SAFER (main)
SAFER (main)

... - Three basic types of firing circuits • Capacitive Discharge – most common at NASA • Constant Current – occasionally used • Constant Voltage - rare ...
Using Thyristors in Heating Applications
Using Thyristors in Heating Applications

... To provide full protection for thyristor devices is not straightforward. In particular the use of HBC fuses (type gG or gL in Europe) alone will most probably not offer adequate protection against either overload or short circuit. Special semiconductor fuses (type aR) provide correct protection agai ...
Control Circuit Transients - GE Grid Solutions Online Store
Control Circuit Transients - GE Grid Solutions Online Store

CGD15HB62LP
CGD15HB62LP

... • PWM Signals: High side and low side PWM must be differential signals 4. The termination impedance of the differential receiver is 250 Ω. A reference single-ended to differential converter is available as an optimized companion product. Overlap protection is provided to prevent both the high side a ...
Copper losses
Copper losses

... Eddy current, and hysteresis losses are called ‘iron losses’. This type of loss is a magnetic loss. The eddy current, particularly within a material such as iron, can cause quite a large increase in temperature, and consequent power loss. Solution = laminated cores (these reduce the losses) Hysteres ...
Chapter 3 Special-Purpose Diodes
Chapter 3 Special-Purpose Diodes

... Mutual inductance is a phenomenon basic to the operation of the transformer, an electrical device used today in almost every field of electrical engineering. This device plays an integral part in power distribution systems and can be found in many electronic circuits and measuring instruments. In th ...
Lab 2
Lab 2

< 1 ... 195 196 197 198 199 200 201 202 203 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report