• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
sirius - Siemens
sirius - Siemens

Bourns® FLAT® Technology Gas Discharge Tube (GDT) Surge
Bourns® FLAT® Technology Gas Discharge Tube (GDT) Surge

AN11176 Automotive qualified ESD protection for LVDS
AN11176 Automotive qualified ESD protection for LVDS

Oil transformers
Oil transformers

Cable System Transient Study
Cable System Transient Study

Microstrip, Stripline, and CPW Design
Microstrip, Stripline, and CPW Design

... indicated above in a defined cross-section and a defined time.  Because the region between the two outer plates of Stripline contains only a single medium, the phase velocity and the characteristic impedance of the dominant mode TEM do not vary with frequency.  In the fundamental mode the hot cond ...


... off-site ac power for the LNP 1 and LNP 2 via a common switchyard. The connections of LNP 1, LNP 2, the switchyard, and the 500 kV transmission system are shown in Figures 8.2-201 and 8.2-202 respectively. The common 500 kV/230 kV switchyard provides a 500 kV circuit feed to the main step-up transfo ...
certification impact analysis: ul/iec 60950-1
certification impact analysis: ul/iec 60950-1

Practical Aspects of Rogowski Coil Applications to Relaying
Practical Aspects of Rogowski Coil Applications to Relaying

Information and Requirements for Electrical Service
Information and Requirements for Electrical Service

... These specifications, which protect the mutual interests of the Customer and Company, may be revised or amended from time to time in keeping with developments and progress of the industry. For the latest official version of this document please visit the Company’s web site address at: http://www.nat ...
Aalborg Universitet SYSTEMS Choi, Uimin
Aalborg Universitet SYSTEMS Choi, Uimin

... Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights. ? Users may download a ...
ServoOne Operation Manual Single-Axis System
ServoOne Operation Manual Single-Axis System

... machine or plant is itself responsible for ensuring that the drive is rendered safe if the device fails. The standard EN 60204-1/DIN VDE 0113 “Safety of machines”, under the subject “Electrical equipment of machines”, stipulates safety requirements for electrical controls. They are intended for the ...
Circuit Measurement
Circuit Measurement

... 17. State the electrical quantity measured by an ohmmeter, the second use of an ohmmeter, and the way in which an ohmmeter is connected to a resistance being measured. 18. State the method used to allow an ohmmeter to measure different ranges and the area of an ohmmeter scale that should be used whe ...
Short-Circuit Current Rating (Calculations and Marking) 2008 SPD
Short-Circuit Current Rating (Calculations and Marking) 2008 SPD

... industrial control panel. In previous editions of the NEC® (2002 Edition) and NFPA 79 (2002 Edition), the industrial machine nameplate was required to include only the interrupting rating of the machine overcurrent protective device, if furnished. This marking was misleading as it did not represent ...
About Fusetek FUSETEK is a 100% family owned
About Fusetek FUSETEK is a 100% family owned

... fuses and fuse application. Always, we have stressed product understanding before product specification. This software is a natural extension of what we have been ‘preaching’ for the last 35 years. The fact that there has been much talk and debate over correct fuse protection for control (and IEC co ...
EP Convection Air Heaters Hazardous Locations
EP Convection Air Heaters Hazardous Locations

User Manual S811+ Soft Starter Effective November 2012 Supersedes July 2012
User Manual S811+ Soft Starter Effective November 2012 Supersedes July 2012

Medium Voltage Metal-Clad Switchgear Specification
Medium Voltage Metal-Clad Switchgear Specification

... mounted on the front of the switchgear panels and arranged in an approved, logical, symmetrical manner. In those cases where there is not enough space on the door of the instrument compartment, a 10” front extension shall be installed to mount metering, protection, and control devices. 4.10. The bre ...
The Complete Guide to Electrical Insulation Testing
The Complete Guide to Electrical Insulation Testing

... Every electric wire in your plant – whether it’s in a motor, generator, cable, switch, transformer, etc. – is carefully covered with some form of electrical insulation. The wire itself is usually copper or aluminum, which is known to be a good conductor of the electric current that powers your equip ...
R 4series 74-84 Three phase digital speed
R 4series 74-84 Three phase digital speed

... stop the motor. This motor can itself sustain stoppage by a mechanical lock. Finally, voltage variations, in particular power cuts, may also cause stoppages to occur. The disappearance of causes of stoppage could cause restarting, dangerous to some machines or installations, in particular those whic ...
Eaton`s guide to surge suppression
Eaton`s guide to surge suppression

Operating Manual SUNNY TRIPOWER 5000TL / 6000TL / 7000TL /
Operating Manual SUNNY TRIPOWER 5000TL / 6000TL / 7000TL /

switchboards
switchboards

Click here for a
Click here for a

Improving Breaker Failure Protection for Generator Applications
Improving Breaker Failure Protection for Generator Applications

< 1 ... 8 9 10 11 12 13 14 15 16 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report