
SSPA 9.5-10.5-25 DS_SSPA 9.5-10.5-25 DS.qxd
... gain flatness is ±2.0 dB across the band. Noise Figure is 5.5 dB typical at 25ºC. Input VSWR is 2.0:1 maximum. Output VSWR is 2.0:1 maximum. This unit is equipped with Aethercomm's proprietary DC switching circuitry that enables and disables the DC-DC circuitry in 500/600 nSec typical on this unit. ...
... gain flatness is ±2.0 dB across the band. Noise Figure is 5.5 dB typical at 25ºC. Input VSWR is 2.0:1 maximum. Output VSWR is 2.0:1 maximum. This unit is equipped with Aethercomm's proprietary DC switching circuitry that enables and disables the DC-DC circuitry in 500/600 nSec typical on this unit. ...
LEDAY7W Technical Catalogue
... 1.Armature can be mounted on the surface, in parallel or inclined way. 2.If it will be connected parallel then additional mounting apparatus are not needed. The armature is mounted to the surface from the mounting holes with four suitable screws. If inclined mounting will be done then firstly, addit ...
... 1.Armature can be mounted on the surface, in parallel or inclined way. 2.If it will be connected parallel then additional mounting apparatus are not needed. The armature is mounted to the surface from the mounting holes with four suitable screws. If inclined mounting will be done then firstly, addit ...
27.09.2013 1 / 2 QUESTION: What is the difference between cosine
... It is a real picture of line power. Voltage is sinusoidal, but not current. It is also easy to see that the fundamental waves of voltage and current almost have unity phase. Because the voltage is sinusoidal, U = 0 V for > 1, it means that only on the fundamental components contribute to the RMS val ...
... It is a real picture of line power. Voltage is sinusoidal, but not current. It is also easy to see that the fundamental waves of voltage and current almost have unity phase. Because the voltage is sinusoidal, U = 0 V for > 1, it means that only on the fundamental components contribute to the RMS val ...
560PSR00 Data sheet
... and 560SFR02. The output power is sufficient to supply a subrack with up to 4 communication units (CMU). It is possible to configure redundant power supplies for project configurations with higher requirements to availability. In this configuration two power supply units 560PSR00 are operating in pa ...
... and 560SFR02. The output power is sufficient to supply a subrack with up to 4 communication units (CMU). It is possible to configure redundant power supplies for project configurations with higher requirements to availability. In this configuration two power supply units 560PSR00 are operating in pa ...
Using Multiple-Channel Power Supplies for Maximum Flexibility
... voltages to power all the analog and digital circuit sub systems. During development and testing, a number of single-channel power supplies can be used to power up each circuit section. Alternatively, a multiple-channel power supply could meet all your requirements and reduce the number of instrumen ...
... voltages to power all the analog and digital circuit sub systems. During development and testing, a number of single-channel power supplies can be used to power up each circuit section. Alternatively, a multiple-channel power supply could meet all your requirements and reduce the number of instrumen ...
Uninterrupted Motive Power Supply (UMPS) Catalogue
... Motive Power Supply) which carries out the function of providing power to load in case of blackout while at the same time does not require to be oversized in its rating. This is also an energy efficient solution as compared to conventional UPS. Uninterrupted Motive Power Supply (UMPS) is the most re ...
... Motive Power Supply) which carries out the function of providing power to load in case of blackout while at the same time does not require to be oversized in its rating. This is also an energy efficient solution as compared to conventional UPS. Uninterrupted Motive Power Supply (UMPS) is the most re ...
2Amp Standard Power Supply - Inner Range Unauthorized Access
... can be used wherever battery backed 12V supplies are required. The Standard 2Amp power supply boasts a highly reliable design that offers exceptional stability when used with the recommended battery type and is also suitable for providing power to card readers including Proximity type reader heads. ...
... can be used wherever battery backed 12V supplies are required. The Standard 2Amp power supply boasts a highly reliable design that offers exceptional stability when used with the recommended battery type and is also suitable for providing power to card readers including Proximity type reader heads. ...
05VoltageCurrentPower
... 14. When all the generators are running at Hoover Dam, it produces 2,000,000,000 Watts. This power is then sent elsewhere by power lines. The diagram at right is a simplified version of the situation, where the battery represents the generators and the light bulb represents the city that uses the po ...
... 14. When all the generators are running at Hoover Dam, it produces 2,000,000,000 Watts. This power is then sent elsewhere by power lines. The diagram at right is a simplified version of the situation, where the battery represents the generators and the light bulb represents the city that uses the po ...
ea-380dgreen
... 80 PLUS® Bronze certification is among the highest independent standards in power supply efficiency. This allows the PSU to use less energy and generate less heat so it stays cooler, runs more quietly, and lasts longer. The EA-380D Green has been certified to be at least 82% efficient at a wide rang ...
... 80 PLUS® Bronze certification is among the highest independent standards in power supply efficiency. This allows the PSU to use less energy and generate less heat so it stays cooler, runs more quietly, and lasts longer. The EA-380D Green has been certified to be at least 82% efficient at a wide rang ...
optotronic ® ot 120/220-240/12 p
... OPTOTRONIC® OT 120/220-240/12 P Constant Voltage LED Power supply for 12V LED - Modules 1. Technical Data Nominal Voltage Input Voltage ...
... OPTOTRONIC® OT 120/220-240/12 P Constant Voltage LED Power supply for 12V LED - Modules 1. Technical Data Nominal Voltage Input Voltage ...
High-voltage power supply, 25 kV
... handled carelessly. Whenever there are grounds for assuming that safe operation may no longer be possible (e.g. when the device is visibly damaged), shut off the device immediately . • Before putting the high voltage power supply 25 kV into operation, always inspect the housing and the control and d ...
... handled carelessly. Whenever there are grounds for assuming that safe operation may no longer be possible (e.g. when the device is visibly damaged), shut off the device immediately . • Before putting the high voltage power supply 25 kV into operation, always inspect the housing and the control and d ...
Conditioned. Protected.
... From APC’s power engineering labs comes the H Type Power Conditioner, a single unit that delivers pure, stable power for high performance AV. The preferred choice of power protection for high performance home entertainment systems, the H Type Power Conditioner combines surge protection, isolated noi ...
... From APC’s power engineering labs comes the H Type Power Conditioner, a single unit that delivers pure, stable power for high performance AV. The preferred choice of power protection for high performance home entertainment systems, the H Type Power Conditioner combines surge protection, isolated noi ...
GSM160B series
... Protections: Short circuit / Overload / Over voltage / Over temperature Fully enclosed plastic case LED indicator for power on 100% full load burn-in test 3 years warranty ...
... Protections: Short circuit / Overload / Over voltage / Over temperature Fully enclosed plastic case LED indicator for power on 100% full load burn-in test 3 years warranty ...
chapter 8 - Power Quality
... Voltage flicker is most commonly caused by rapidly varying loads that require a large amount of reactive power such as welders. It can cause visible flicker in lights and cause other processes to shut down or malfunction. ...
... Voltage flicker is most commonly caused by rapidly varying loads that require a large amount of reactive power such as welders. It can cause visible flicker in lights and cause other processes to shut down or malfunction. ...
7810-12
... • PD3 gives ratio of power if two processors were tuned* to yield the same performance • (PD3)1/3 gives ratio of performance if two processors were tuned* to yield the same power ...
... • PD3 gives ratio of power if two processors were tuned* to yield the same performance • (PD3)1/3 gives ratio of performance if two processors were tuned* to yield the same power ...
chapter 7 - Portal UniMAP
... causes of sags are the switching on of large loads, or short circuits on the power line. They are also caused by temporary heavy demand for electricity that exceeds the utilities capability to meet it. ...
... causes of sags are the switching on of large loads, or short circuits on the power line. They are also caused by temporary heavy demand for electricity that exceeds the utilities capability to meet it. ...
installation instructions
... USA, Europe and other countries) must be ensured. Before operation is started the following conditions must be ensured: Connection to power supply in compliance with national regulations (e.g. VDE0100 and EN50178). By use of stranded wires, all strands must be fastened in the terminal blocks. (P ...
... USA, Europe and other countries) must be ensured. Before operation is started the following conditions must be ensured: Connection to power supply in compliance with national regulations (e.g. VDE0100 and EN50178). By use of stranded wires, all strands must be fastened in the terminal blocks. (P ...
Ground Power Supply The external AC ground supply receptacle is
... The external power is controlled from the flight compartment and can be energized with or without the main aircraft battery. The external power either supplies automatically all the busbars by means of the EXT PWR pushbutton switch or separately supplies the ground service busbar. An amber warning l ...
... The external power is controlled from the flight compartment and can be energized with or without the main aircraft battery. The external power either supplies automatically all the busbars by means of the EXT PWR pushbutton switch or separately supplies the ground service busbar. An amber warning l ...
Document
... This thesis deal among Power Factor Correction (PFC) in Brushless motor drives by comparing various DC-DC converter topologies. To improve the Power quality (PQ) power factor corrected converter is essential. VSI is used for speed control. In order to condense conduction loss and quantity of compone ...
... This thesis deal among Power Factor Correction (PFC) in Brushless motor drives by comparing various DC-DC converter topologies. To improve the Power quality (PQ) power factor corrected converter is essential. VSI is used for speed control. In order to condense conduction loss and quantity of compone ...
Comparison Between Vacuum Tube and Solid
... 5) Loses energy only during “Switching” and “On” states. The overall energy loss is relatively low compared to that of the vacuum tube. 6) Has a typical Energy Efficiency of about 90% which does not decrease with lower output voltage. ...
... 5) Loses energy only during “Switching” and “On” states. The overall energy loss is relatively low compared to that of the vacuum tube. 6) Has a typical Energy Efficiency of about 90% which does not decrease with lower output voltage. ...
AC adapter

An AC adapter, AC/DC adapter, or AC/DC converter is a type of external power supply, often enclosed in a case similar to an AC plug. Other common names include plug pack, plug-in adapter, adapter block, domestic mains adapter, line power adapter, wall wart, power brick, and power adapter. Adapters for battery-powered equipment may be described as chargers or rechargers (see also battery charger).AC adapters are used with electrical devices that require power but do not contain internal components to derive the required voltage and power from mains power. The internal circuitry of an external power supply is very similar to the design that would be used for a built-in or internal supply.External power supplies are used both with equipment with no other source of power and with battery-powered equipment, where the supply, when plugged in, can sometimes charge the battery in addition to powering the equipment.Use of an external power supply allows portability of equipment powered either by mains or battery without the added bulk of internal power components, and makes it unnecessary to produce equipment for use only with a specified power source; the same device can be powered from 120VAC or 230VAC mains, vehicle or aircraft battery by using a different adapter.