07882-000 TX1
... Turn off and on the power. Push Stop + Slow together , and you are in setup mode. Push Stop + Fast together in setup mode, and you are in Diagnostic mode. Using fast, slow key to select "LAST ERROR : "(clear last error) and push Start to clear the ...
... Turn off and on the power. Push Stop + Slow together , and you are in setup mode. Push Stop + Fast together in setup mode, and you are in Diagnostic mode. Using fast, slow key to select "LAST ERROR : "(clear last error) and push Start to clear the ...
description features applications
... A11/D0 pins. For example, when the A0 (Pin No. 1) is set to “1” (Vcc), the Code Bit A0 is synthesized as “1” bit. In the same manner, when it (A0 Pin) is set to “0” (Vss) or left floating, the Code Bit A0 is synthesized as a “0” or “f” bit respectively. ...
... A11/D0 pins. For example, when the A0 (Pin No. 1) is set to “1” (Vcc), the Code Bit A0 is synthesized as “1” bit. In the same manner, when it (A0 Pin) is set to “0” (Vss) or left floating, the Code Bit A0 is synthesized as a “0” or “f” bit respectively. ...
Digital Devices
... Activity Factor • Suppose the system clock frequency = f • Let fsw = af, where a = activity factor – If the signal is a clock, a = 1 – If the signal switches once per cycle, a = ½ – Dynamic gates (ie., domino logic): • Switch either 0 or 2 times per cycle, a = ½ – Static gates: • Depends on design, ...
... Activity Factor • Suppose the system clock frequency = f • Let fsw = af, where a = activity factor – If the signal is a clock, a = 1 – If the signal switches once per cycle, a = ½ – Dynamic gates (ie., domino logic): • Switch either 0 or 2 times per cycle, a = ½ – Static gates: • Depends on design, ...
additional maximum voltage and maximum power transfer conditions
... These are based on an analytic solution to the problem of stability limits of radial transmission circuits with inter-nodal constraints as shown in Figure 1 where maximum received power is defined by the resulting magnitudes of sending and receiving end voltages as the angular separation between the ...
... These are based on an analytic solution to the problem of stability limits of radial transmission circuits with inter-nodal constraints as shown in Figure 1 where maximum received power is defined by the resulting magnitudes of sending and receiving end voltages as the angular separation between the ...
NetForce Whitepaper Series
... Another cause for noise may be a split pair. A split pair is a wiring mistake made when a wire of one pair is incorrectly spliced to another wire of an adjacent pair. Splits are often connected by reconnecting the pair further down the line. When a split occurs, the impedance of the pair changes and ...
... Another cause for noise may be a split pair. A split pair is a wiring mistake made when a wire of one pair is incorrectly spliced to another wire of an adjacent pair. Splits are often connected by reconnecting the pair further down the line. When a split occurs, the impedance of the pair changes and ...
Power line chokes - Current-compensated frame core
... 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly poin ...
... 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly poin ...
BSPM4275TNS(R) / BSPH4275TT(R)
... The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information th ...
... The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information th ...
Ultra-Precision CML AnyGate with Internal Input and Output
... Micrel makes no representations or warranties with respect to the accuracy or completeness of the information furnished in this data sheet. This information is not intended as a warranty and Micrel does not assume responsibility for its use. Micrel reserves the right to change circuitry, specificati ...
... Micrel makes no representations or warranties with respect to the accuracy or completeness of the information furnished in this data sheet. This information is not intended as a warranty and Micrel does not assume responsibility for its use. Micrel reserves the right to change circuitry, specificati ...
“Graphs as bridges between mathematical description and
... Although power increases when current increases, the ratio between the increases is clearly not invariant as it was for the straight line graph. Software tools allow the properties of this shape of curve to be explored: Cursors are used to calculate successive increases in power for a given increase ...
... Although power increases when current increases, the ratio between the increases is clearly not invariant as it was for the straight line graph. Software tools allow the properties of this shape of curve to be explored: Cursors are used to calculate successive increases in power for a given increase ...
Description Installation Units Definition of the Output Data
... using a second way, independent from the normal control circuit. This state is being stored. If no energy is being fed from an external source, the output circuit will discharge. If the overvoltage protection has been triggered by an external overvoltage pulse, normal operation mode of the power sup ...
... using a second way, independent from the normal control circuit. This state is being stored. If no energy is being fed from an external source, the output circuit will discharge. If the overvoltage protection has been triggered by an external overvoltage pulse, normal operation mode of the power sup ...
Benefits of Voltage Optimisation
... Energy saving through Voltage Optimisation is based on the principle that the nameplate power of a device, such as 1kW for an electric fire, will be delivered at any voltage within an operating range. In the UK the range is 207V to 253V. However, above optimum voltage, any additional energy used wil ...
... Energy saving through Voltage Optimisation is based on the principle that the nameplate power of a device, such as 1kW for an electric fire, will be delivered at any voltage within an operating range. In the UK the range is 207V to 253V. However, above optimum voltage, any additional energy used wil ...
MAX16056–MAX16059 125nA Supervisory Circuits with Capacitor- Adjustable Reset and Watchdog Timeouts General Description
... (high-to-low) the watchdog input (WDI) within the capacitor-adjustable watchdog timeout period (tWD), RESET asserts for the reset timeout period (tRP). The internal watchdog timer is cleared by: 1) any event that asserts RESET, by 2) a falling transition at WDI (that can detect pulses as short as 15 ...
... (high-to-low) the watchdog input (WDI) within the capacitor-adjustable watchdog timeout period (tWD), RESET asserts for the reset timeout period (tRP). The internal watchdog timer is cleared by: 1) any event that asserts RESET, by 2) a falling transition at WDI (that can detect pulses as short as 15 ...
Theory
... 6) Now adjust the sweep speed on the oscilloscope (also the horizontal. magnification, if necessary) until only the first half of the trace shown in Figure 2 fills the screen. The horizontal adjustments, except for calibration, can be changed at will; however, do not change the vertical settings. 7 ...
... 6) Now adjust the sweep speed on the oscilloscope (also the horizontal. magnification, if necessary) until only the first half of the trace shown in Figure 2 fills the screen. The horizontal adjustments, except for calibration, can be changed at will; however, do not change the vertical settings. 7 ...
PU500-series 400 to 500 W
... Inrush current limit with NTC Reduces the inrush current during start up. The input voltage range will be affected. Only available on 110 & 220 input code. ...
... Inrush current limit with NTC Reduces the inrush current during start up. The input voltage range will be affected. Only available on 110 & 220 input code. ...
X9119 - Intersil
... The basic sequence of the four byte instructions is illustrated in Figure 6 on page 8. These 4-byte instructions exchange data between the WCR and one of the data registers. A transfer from a data register to a WCR is essentially a write to a static RAM, with the static RAM controlling the wiper pos ...
... The basic sequence of the four byte instructions is illustrated in Figure 6 on page 8. These 4-byte instructions exchange data between the WCR and one of the data registers. A transfer from a data register to a WCR is essentially a write to a static RAM, with the static RAM controlling the wiper pos ...
iC-GE / iC-GE100 - iC-Haus
... removal of the power supply; the current depletion in the coil is supported by switching the free-wheeling circuit to a higher voltage. To this end a Zener diode is activated for a quicker demagnetising of the coil. The status indicator LED is constantly ON when hold mode is functioning correctly an ...
... removal of the power supply; the current depletion in the coil is supported by switching the free-wheeling circuit to a higher voltage. To this end a Zener diode is activated for a quicker demagnetising of the coil. The status indicator LED is constantly ON when hold mode is functioning correctly an ...
INTRODUCTION
... The F-to-I converter acts as a current controlling device. Thus, the current output remains the same even if the power supply voltage fluctuates or the load resistance changes. The current varies only with respect to the flow rate from the turbine flow meter, as long as the voltage drop across the F ...
... The F-to-I converter acts as a current controlling device. Thus, the current output remains the same even if the power supply voltage fluctuates or the load resistance changes. The current varies only with respect to the flow rate from the turbine flow meter, as long as the voltage drop across the F ...