True RMS Multimeter
... shorten the life of the electronic parts and distort or melt plastic parts. 3. HANDLE THE METER GENTLY AND CAREFULLY. Dropping it can damage the electronic parts or the case. 4. KEEP THE METER CLEAN. Wipe the case occasionally with a damp cloth. DO NOT use chemicals, cleaning solvents, or detergents ...
... shorten the life of the electronic parts and distort or melt plastic parts. 3. HANDLE THE METER GENTLY AND CAREFULLY. Dropping it can damage the electronic parts or the case. 4. KEEP THE METER CLEAN. Wipe the case occasionally with a damp cloth. DO NOT use chemicals, cleaning solvents, or detergents ...
abstract - Wine Yard Technologies
... ZigBee is the name of a specification for a suite of high level communication protocols using small, low-power digital radios based on the IEEE 802.15.4 standard for wireless personal area networks (WPANs), such as wireless headphones connecting with cell phones via short range radio. The technology ...
... ZigBee is the name of a specification for a suite of high level communication protocols using small, low-power digital radios based on the IEEE 802.15.4 standard for wireless personal area networks (WPANs), such as wireless headphones connecting with cell phones via short range radio. The technology ...
design and implementation of power factor correction (pfc)
... Digital signal processing (DSP) are designed for the purpose of control loop implementation, and are widely used on motor controlling, uninterruptible power supplies (UPS) and movement controlling applications. Owing to their high CPU bandwidth and the peripherals, integrated with them, in order to ...
... Digital signal processing (DSP) are designed for the purpose of control loop implementation, and are widely used on motor controlling, uninterruptible power supplies (UPS) and movement controlling applications. Owing to their high CPU bandwidth and the peripherals, integrated with them, in order to ...
Reigh Walling Commen.. - pes-psrc
... In addition to the various currents and voltages to be provided for the various faults at the indicated locations for the indicated cases, also indicate if there is a threshold voltage at the point of interconnection at which the fault current contribution changes suddenly, for instance if a crowbar ...
... In addition to the various currents and voltages to be provided for the various faults at the indicated locations for the indicated cases, also indicate if there is a threshold voltage at the point of interconnection at which the fault current contribution changes suddenly, for instance if a crowbar ...
doc
... a default constructed description. It is recommended that the user configure the description object first to ensure that the FED runs as desired. The simplest way to configure a FED using a Fed9UVmeDevice object is with the initialisation methods provided by Fed9UVmeDevice. They can be used to setup ...
... a default constructed description. It is recommended that the user configure the description object first to ensure that the FED runs as desired. The simplest way to configure a FED using a Fed9UVmeDevice object is with the initialisation methods provided by Fed9UVmeDevice. They can be used to setup ...
OPERATOR`S MANUAL LOGIC PROBE (Model 610. 610B. 615. 625)
... The Logic Pulser is a very effective tool for inspecting and repairing the logic circuits. It can be used directly to inject a signal into the logic circuits without removing the IC or breaking the circuits. The 100mA pulse output insures that the device under test will be pulsed, while the short 10 ...
... The Logic Pulser is a very effective tool for inspecting and repairing the logic circuits. It can be used directly to inject a signal into the logic circuits without removing the IC or breaking the circuits. The 100mA pulse output insures that the device under test will be pulsed, while the short 10 ...
AN-MC-004: How to wire a motor starter
... SUPPLIED “AS IS” WITHOUT A GUARANTEE OF ANY KIND. We do not guarantee that the data is suitable for your particular application nor we do assume any responsibility for them in your application. a) Full voltage non reversible 3 phase motors. The following diagram is shown for a 3-wire control with 24 ...
... SUPPLIED “AS IS” WITHOUT A GUARANTEE OF ANY KIND. We do not guarantee that the data is suitable for your particular application nor we do assume any responsibility for them in your application. a) Full voltage non reversible 3 phase motors. The following diagram is shown for a 3-wire control with 24 ...
SUPERPOSITION
... Add all the computed values obtained from analysing the circuit with each source acting alone. The sum is the actual voltage or current when all sources are acting simultaneously (i.e. when all the sources are present) Important to take into account the polarities of the quantities being added. E.g. ...
... Add all the computed values obtained from analysing the circuit with each source acting alone. The sum is the actual voltage or current when all sources are acting simultaneously (i.e. when all the sources are present) Important to take into account the polarities of the quantities being added. E.g. ...
AD7675 数据手册DataSheet下载
... When SER/PAR is LOW, this output is used as the Bit 8 of the Parallel Port Data Output Bus. When SER/PAR is HIGH, this output, part of the serial port, is used as a serial data output synchronized to SCLK. Conversion results are stored in an on-chip register. The AD7675 provides the conversion resul ...
... When SER/PAR is LOW, this output is used as the Bit 8 of the Parallel Port Data Output Bus. When SER/PAR is HIGH, this output, part of the serial port, is used as a serial data output synchronized to SCLK. Conversion results are stored in an on-chip register. The AD7675 provides the conversion resul ...
2 Impedance and Transfer Functions
... residual high frequency component, and does that amplitude agree with expectations? Repeat these measurements with a high-pass filter using the same R and C. ...
... residual high frequency component, and does that amplitude agree with expectations? Repeat these measurements with a high-pass filter using the same R and C. ...
POWER ELECTRONICS NOTES 10ES45
... The pulse width (conduction period) of the transistors is maintained constant and the variation in output voltage is obtained by varying the DC voltage. The output voltage waveforms with a resistive load for different dc input voltages are shown in Fig. 8.19. ...
... The pulse width (conduction period) of the transistors is maintained constant and the variation in output voltage is obtained by varying the DC voltage. The output voltage waveforms with a resistive load for different dc input voltages are shown in Fig. 8.19. ...
V. Oscillators
... The previous relaxation generators were designed from R, C and op-amp or a form of digital logic (see Fig.2, inverters). The next, higher level is the use of ICs generators or oscillators. They are specially design ICs. The most popular are the 555 and its successors. See Fig.3. ...
... The previous relaxation generators were designed from R, C and op-amp or a form of digital logic (see Fig.2, inverters). The next, higher level is the use of ICs generators or oscillators. They are specially design ICs. The most popular are the 555 and its successors. See Fig.3. ...
PowerPac™ Basic Power Supply Instruction Manual - Bio-Rad
... clearance around the power supply. Do not block the fan vents at the rear of the unit. 2. Always connect the power supply to a 3-prong, grounded AC outlet, using the 3-prong AC power cord provided with the power supply. 3. Bio-Rad electrophoresis cells have molded two-prong plugs that are inserted i ...
... clearance around the power supply. Do not block the fan vents at the rear of the unit. 2. Always connect the power supply to a 3-prong, grounded AC outlet, using the 3-prong AC power cord provided with the power supply. 3. Bio-Rad electrophoresis cells have molded two-prong plugs that are inserted i ...
Lab 3 - RS-232 Serial Interface Waveform
... Run Teraterm. Select serial port input using COM1 displayed, and a copy of your code with any addiwhen the program starts. Select Setup->Serial Port tional changes you made during the lab. Submit your lab report using the Lab 3 Report dropbox on the and set the baud rate for COM1 to 1200 bps. If you ...
... Run Teraterm. Select serial port input using COM1 displayed, and a copy of your code with any addiwhen the program starts. Select Setup->Serial Port tional changes you made during the lab. Submit your lab report using the Lab 3 Report dropbox on the and set the baud rate for COM1 to 1200 bps. If you ...
AD590 Datasheet
... resistance measuring circuitry and cold junction compensation are not needed in applying the AD590. In the simplest application, a resistor, a power source and any voltmeter can be used to measure temperature. In addition to temperature measurement, applications include temperature compensation or c ...
... resistance measuring circuitry and cold junction compensation are not needed in applying the AD590. In the simplest application, a resistor, a power source and any voltmeter can be used to measure temperature. In addition to temperature measurement, applications include temperature compensation or c ...