docx - HEP Educational Outreach
... 1. Create a Transfer Function for the TNG-3B ADC The first thing to understand about an ADC is how it converts the input analog voltage to an output digitized number. This is the core of the data conversion process. Set up the equipment to measure the transfer function. You will need to use the LabV ...
... 1. Create a Transfer Function for the TNG-3B ADC The first thing to understand about an ADC is how it converts the input analog voltage to an output digitized number. This is the core of the data conversion process. Set up the equipment to measure the transfer function. You will need to use the LabV ...
1. Pre-Lab Introduction
... step-down transformer is used to decrease the AC line voltage from 115 VRMS to an RMS value near the DC voltage needed. The output of the step-down transformer is then fed into a diode rectifier circuit that only outputs positive halves of the input sinusoid. A filter is then used to smooth the rect ...
... step-down transformer is used to decrease the AC line voltage from 115 VRMS to an RMS value near the DC voltage needed. The output of the step-down transformer is then fed into a diode rectifier circuit that only outputs positive halves of the input sinusoid. A filter is then used to smooth the rect ...
TARGA III - Lion Precision
... The TARGA III is compliant with the following CE directives: Safety: 61010-1:2001 EMC: 61326-1, 61326-2-3 To maintain compliance with these standards, the following operating conditions must be maintained: ...
... The TARGA III is compliant with the following CE directives: Safety: 61010-1:2001 EMC: 61326-1, 61326-2-3 To maintain compliance with these standards, the following operating conditions must be maintained: ...
Electromagnetic Simulation for Power Integrity: From Analysis to
... Signal degradation / Jitter Power supply noise Electromagnetic interference ...
... Signal degradation / Jitter Power supply noise Electromagnetic interference ...
XMC – 32-Bit Industrial Microcontrollers
... Resolvers can be direct connected with ΔΣ Demodulator In-phase current measurement via galvanic isolated ΔΣ Demodulator Easy 3-phase inverter implementation with CCU8 Sensor calibration, offset and gain adjustment with fast ...
... Resolvers can be direct connected with ΔΣ Demodulator In-phase current measurement via galvanic isolated ΔΣ Demodulator Easy 3-phase inverter implementation with CCU8 Sensor calibration, offset and gain adjustment with fast ...
Burr Brown PCM63K
... Because of the unique dual-DAC Colinear architecture of the PCM63P, increasing values of digital input will always result in increasing values of DAC output as the signal moves away from bipolar zero in one-LSB steps (in either direction). The “16-Bit Monotonicity” plot in the Typical Performance Cu ...
... Because of the unique dual-DAC Colinear architecture of the PCM63P, increasing values of digital input will always result in increasing values of DAC output as the signal moves away from bipolar zero in one-LSB steps (in either direction). The “16-Bit Monotonicity” plot in the Typical Performance Cu ...
Loadlines Made Simpl..
... Subtract this value from the supply voltage and you get the plate voltage that results from this particular plate current (300v - 50v = 250v). Do this calculation for all current values from 0 to 3mA and you will always find that the (Va,Ia) point is lying on the loadline. Got this? OK, let's go on ...
... Subtract this value from the supply voltage and you get the plate voltage that results from this particular plate current (300v - 50v = 250v). Do this calculation for all current values from 0 to 3mA and you will always find that the (Va,Ia) point is lying on the loadline. Got this? OK, let's go on ...
DN159 - New 14-Bit, 800ksps ADC Upgrades
... Both analog inputs have infinite DC input resistance, which makes them easy to multiplex or AC couple. ...
... Both analog inputs have infinite DC input resistance, which makes them easy to multiplex or AC couple. ...
ohm`s law
... 2. Before the power supply is turned on, have your instructor inspect the circuit. Turn on the power supply and slowly increase the voltage until the ammeter reads 100 mA. Record the voltage drop across and current through the resistor in ten steps up to a maximum of 1.0A. 50 Ohm Resistor 3. Replace ...
... 2. Before the power supply is turned on, have your instructor inspect the circuit. Turn on the power supply and slowly increase the voltage until the ammeter reads 100 mA. Record the voltage drop across and current through the resistor in ten steps up to a maximum of 1.0A. 50 Ohm Resistor 3. Replace ...
Optimal Placement of Unified Power Flow Controller for
... and reactive powers leaving the UPFC, towards the farthest bus. Moreover, the UPFC’s shunt converter is set to regulate nearest voltage magnitude of its nearest bus. The application of GA to the problem indicate that the best UPFC location satisfying the condition of minimum line losses occurs when ...
... and reactive powers leaving the UPFC, towards the farthest bus. Moreover, the UPFC’s shunt converter is set to regulate nearest voltage magnitude of its nearest bus. The application of GA to the problem indicate that the best UPFC location satisfying the condition of minimum line losses occurs when ...
IEEE NANO 2007 Paper
... SRAM based Flip-Flop is widely used as internal memory to store and synchronize the data processed in the Field Programmable Gate Array (FPGA) and System On Circuit (SOC) circuits, but as the SRAM is volatile, all the data stored in these Flip-Flops is lost when the power goes down, FlipFlop based o ...
... SRAM based Flip-Flop is widely used as internal memory to store and synchronize the data processed in the Field Programmable Gate Array (FPGA) and System On Circuit (SOC) circuits, but as the SRAM is volatile, all the data stored in these Flip-Flops is lost when the power goes down, FlipFlop based o ...
Data Sheet
... CDMA technology leverages high-speed EV-DO Rev A to provide data access at speeds up to 3.1 Mbps with backward compatibility to EV-DO Rev 0 and CDMA 1 x RTT. The ELPRO 615M-1 provides real-time redundancy between carriers in event of a network failure, reliable connectivity for programmable logic co ...
... CDMA technology leverages high-speed EV-DO Rev A to provide data access at speeds up to 3.1 Mbps with backward compatibility to EV-DO Rev 0 and CDMA 1 x RTT. The ELPRO 615M-1 provides real-time redundancy between carriers in event of a network failure, reliable connectivity for programmable logic co ...
1.5 GHz Low Noise Silicon MMIC Amplifier Technical Data INA-52063
... +5␣ volt power supply with a typical current drain of 30 mA. All bias regulation circuitry is integrated into the RFIC. Figure 11 shows a typical implementation of the INA-52063. The supply voltage for the INA-52063 must be applied to two terminals, the VCC pin and the RF Output pin. The VCC connect ...
... +5␣ volt power supply with a typical current drain of 30 mA. All bias regulation circuitry is integrated into the RFIC. Figure 11 shows a typical implementation of the INA-52063. The supply voltage for the INA-52063 must be applied to two terminals, the VCC pin and the RF Output pin. The VCC connect ...
Analog Input Option Card AI-14B
... If any of the control signal input terminals (TC1-TC3) are NOT used, jumper them to the 0V terminal (TC4). Route wires from the drive and connect to the peripheral device. Refer to the drive technical manual for further information on use of shielded cable. f) Important: Because the analog input is ...
... If any of the control signal input terminals (TC1-TC3) are NOT used, jumper them to the 0V terminal (TC4). Route wires from the drive and connect to the peripheral device. Refer to the drive technical manual for further information on use of shielded cable. f) Important: Because the analog input is ...
PI3HDMI412AD_HDMI_ApplicationInformation
... More careful attention must be paid to the details associated with high-speed design as well as providing a clean power supply, some recommendations are listed below. The supply (VDD) and ground (GND) pins should be connected to power planes routed on adjacent layers of the printed circuit board. ...
... More careful attention must be paid to the details associated with high-speed design as well as providing a clean power supply, some recommendations are listed below. The supply (VDD) and ground (GND) pins should be connected to power planes routed on adjacent layers of the printed circuit board. ...
CarSense 101 Vehicle Motion Detector Operating Instructions
... • Connect the probe shield wire (pin 6) to earth ground, not common or box ground. • Relay outputs for Relay1 and Relay 2 are dry contact output and perform switching functions only. The relay connections are isolated from the modules operating supply voltage and will switch voltage of the circuit t ...
... • Connect the probe shield wire (pin 6) to earth ground, not common or box ground. • Relay outputs for Relay1 and Relay 2 are dry contact output and perform switching functions only. The relay connections are isolated from the modules operating supply voltage and will switch voltage of the circuit t ...
1-Wire Addressable Digital Instruments for Environmental
... Atmospheric, or barometric, pressure is a valuable indicator of imminent weather change when a front moves past the instrument. This meteorological parameter can also be measured over a 1-Wire net using an ADI. Selecting a pressure sensor that contains comprehensive onchip signal Figure 6. A baromet ...
... Atmospheric, or barometric, pressure is a valuable indicator of imminent weather change when a front moves past the instrument. This meteorological parameter can also be measured over a 1-Wire net using an ADI. Selecting a pressure sensor that contains comprehensive onchip signal Figure 6. A baromet ...
power quality and its monitoring with using a special technique
... One of the most significant advantages of Navy all-electricship application is to improve the reliability of its power quality monitoring system, especially in the event of damage. Obviously, in that case the whole client-server system cannot work if the server is in the damaged section of ship. Pro ...
... One of the most significant advantages of Navy all-electricship application is to improve the reliability of its power quality monitoring system, especially in the event of damage. Obviously, in that case the whole client-server system cannot work if the server is in the damaged section of ship. Pro ...
Physics 4700 Experiment 4 Transistors - 1 R
... Let XCE = RE /10. The lowest frequency we are concerned with is 30 Hz so: CE = 1/(2πf XCE) = 1/(2π x 30 x (RE/10)) = 30 µF. 9) Finally we need to choose Cin and Cout. Pick these capacitors so we have the –3 dB points at 30 Hz. Remember ω3dB = 1/RC. For the input R ≈ 800 Ω and for the output R ≈ 1 MΩ ...
... Let XCE = RE /10. The lowest frequency we are concerned with is 30 Hz so: CE = 1/(2πf XCE) = 1/(2π x 30 x (RE/10)) = 30 µF. 9) Finally we need to choose Cin and Cout. Pick these capacitors so we have the –3 dB points at 30 Hz. Remember ω3dB = 1/RC. For the input R ≈ 800 Ω and for the output R ≈ 1 MΩ ...
PCA9546A 数据资料 dataSheet 下载
... The pass-gate transistors of the PCA9546A are constructed such that the VCC voltage can be used to limit the maximum voltage that will be passed from one I2C bus to another. Figure 3 shows the voltage characteristics of the pass-gate transistors (note that the graph was generated using the data spec ...
... The pass-gate transistors of the PCA9546A are constructed such that the VCC voltage can be used to limit the maximum voltage that will be passed from one I2C bus to another. Figure 3 shows the voltage characteristics of the pass-gate transistors (note that the graph was generated using the data spec ...
Cut Sheet
... Optional specialty diffuser materials available, including some Lumicor ® recyclable resin materials Easy tool-less relamping Fluorescent, incandescent or low energy, long life LED source MRI option enables use in magnetic resonance imaging (MRI) rooms High power factor electronic ballast ...
... Optional specialty diffuser materials available, including some Lumicor ® recyclable resin materials Easy tool-less relamping Fluorescent, incandescent or low energy, long life LED source MRI option enables use in magnetic resonance imaging (MRI) rooms High power factor electronic ballast ...