MAX1248/MAX1249 +2.7V to +5.25V, Low-Power, 4-Channel, Serial 10-Bit ADCs in QSOP-16 _______________General Description
... The MAX1248 has an internal 2.5V reference, while the MAX1249 requires an external reference. Both parts have a reference-buffer amplifier with a ±1.5% voltage adjustment range. These devices provide a hard-wired SHDN pin and a software-selectable power-down, and can be programmed to automatically s ...
... The MAX1248 has an internal 2.5V reference, while the MAX1249 requires an external reference. Both parts have a reference-buffer amplifier with a ±1.5% voltage adjustment range. These devices provide a hard-wired SHDN pin and a software-selectable power-down, and can be programmed to automatically s ...
Voltage Regulator Placement - WindMil
... • Set Regulation calculates line drop compensation values for each regulator you select. Set Regulation can calculate these values based on specified load centers, or it can calculate them based on a range of voltages. ...
... • Set Regulation calculates line drop compensation values for each regulator you select. Set Regulation can calculate these values based on specified load centers, or it can calculate them based on a range of voltages. ...
74VCX16373 Low Voltage 16-Bit Transparent Latch with 3.6V Tolerant Inputs and Outputs 7
... HIGH Voltage Level LOW Voltage Level Immaterial (HIGH or LOW, inputs may not float) High Impedance Previous O0 before HIGH-to-LOW of Latch Enable ...
... HIGH Voltage Level LOW Voltage Level Immaterial (HIGH or LOW, inputs may not float) High Impedance Previous O0 before HIGH-to-LOW of Latch Enable ...
LM4250 数据资料 dataSheet 下载
... obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the speci ...
... obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the speci ...
MAX3222/MAX3232/MAX3237/MAX3241* 3.0V to 5.5V, Low-Power, up to 1Mbps, True RS-232 ________________General Description
... MAX3237 transmitters guarantee a 250kbps data rate with worst-case loads of 3kΩ in parallel with 1000pF. This provides compatibility with PC-to-PC communication software, such as LapLink. For higher speed serial communications, the MAX3237 features MegaBaud operation. In MegaBaud operating mode (MBA ...
... MAX3237 transmitters guarantee a 250kbps data rate with worst-case loads of 3kΩ in parallel with 1000pF. This provides compatibility with PC-to-PC communication software, such as LapLink. For higher speed serial communications, the MAX3237 features MegaBaud operation. In MegaBaud operating mode (MBA ...
FEATURES GENERAL DESCRIPTION
... loads for the data outputs. Though the I/Ox for the single and double supplies share names on the silkscreen, they are not connected. The PCB is designed for compatibility with the entire ADuM347x family. If the ADuM3471 is replaced by another ADuM347x, other I/O interconnection schemes are possible ...
... loads for the data outputs. Though the I/Ox for the single and double supplies share names on the silkscreen, they are not connected. The PCB is designed for compatibility with the entire ADuM347x family. If the ADuM3471 is replaced by another ADuM347x, other I/O interconnection schemes are possible ...
Measurement of Complex Impedance
... this adjustment, the reference phase angle of 180' read on the voltmeter will then remain almost constant as the frequency of the signal source is varied. Any variation is due to coupler tracking. This tracking is the ratio B1/Ay It can be measured over the desired frequency range by noting its vari ...
... this adjustment, the reference phase angle of 180' read on the voltmeter will then remain almost constant as the frequency of the signal source is varied. Any variation is due to coupler tracking. This tracking is the ratio B1/Ay It can be measured over the desired frequency range by noting its vari ...
a 21 st century nullmeter
... What The Nullmeter Is What The Nullmeter Is Not Where A Nullmeter Is Used Nullmeter Vs. Digital Instruments In Classic Use Practical Issues With Nullmeter Measurements When To Use A Null Meter—And When Not To The Future Of Nullmeters ...
... What The Nullmeter Is What The Nullmeter Is Not Where A Nullmeter Is Used Nullmeter Vs. Digital Instruments In Classic Use Practical Issues With Nullmeter Measurements When To Use A Null Meter—And When Not To The Future Of Nullmeters ...
The ABC`s of Fire Alarm Systems - Section I
... (5) minutes. Batteries are required by the National Fire Alarm Code in all fire alarm systems not having multiple standby generators. The control panel must also be capable of recharging the battery within a specified period after a discharge. BASIC SYSTEM OPERATION Initiating devices employed in a ...
... (5) minutes. Batteries are required by the National Fire Alarm Code in all fire alarm systems not having multiple standby generators. The control panel must also be capable of recharging the battery within a specified period after a discharge. BASIC SYSTEM OPERATION Initiating devices employed in a ...
LTC6360 - Very Low Noise Single-Ended SAR ADC Driver with True Zero Output
... The output can swing from –0.48V to 4.91V. The amplifier is designed to drive a series 10Ω resistor and 330pF capacitor filter network to ground, although larger load capacitances can be driven. An on-chip low noise charge pump generates a small negative voltage (typically –0.6V) at the CPO pin. Thi ...
... The output can swing from –0.48V to 4.91V. The amplifier is designed to drive a series 10Ω resistor and 330pF capacitor filter network to ground, although larger load capacitances can be driven. An on-chip low noise charge pump generates a small negative voltage (typically –0.6V) at the CPO pin. Thi ...
A+ Guide to Hardware, 4e
... • Cooling fan sits on top of processor with wire or clip • Heat sink: clip-on device pulling heat from processor • Cooler: combination of heat sink and cooling fan ...
... • Cooling fan sits on top of processor with wire or clip • Heat sink: clip-on device pulling heat from processor • Cooler: combination of heat sink and cooling fan ...
LMA-3 Multi-sensor Auxiliary Input Device User Manual
... LogWorks 2.0 has the capability to log, display and analyze up to 32 engine parameters. Most users will use less though. Each of the MTS components reads between 1 and 6 engine parameters. To interface a multitude of MTS components to LogWorks with a single connection, the Innovate LogChain concept ...
... LogWorks 2.0 has the capability to log, display and analyze up to 32 engine parameters. Most users will use less though. Each of the MTS components reads between 1 and 6 engine parameters. To interface a multitude of MTS components to LogWorks with a single connection, the Innovate LogChain concept ...
Cookbook for SAR ADC measurements
... worse in the case of sequential sampling, when the previously measured signal was grounded. The disturbance at the ADC input in this case results from the basic principle of operation of the sample and hold (S/H) circuit inherent in a SAR ADC. These disturbances do not have to introduce a loss of co ...
... worse in the case of sequential sampling, when the previously measured signal was grounded. The disturbance at the ADC input in this case results from the basic principle of operation of the sample and hold (S/H) circuit inherent in a SAR ADC. These disturbances do not have to introduce a loss of co ...
Liebert Battery Interface Box SAVE THESE INSTRUCTIONS
... system contains high DC as well as AC voltages. Check for voltage with AC and DC voltmeters before making contact. Special safety precautions are required for procedures involving handling, installing and maintaining the DC system. Only properly trained and qualified personnel wearing appropriate pe ...
... system contains high DC as well as AC voltages. Check for voltage with AC and DC voltmeters before making contact. Special safety precautions are required for procedures involving handling, installing and maintaining the DC system. Only properly trained and qualified personnel wearing appropriate pe ...
Physics – Measurements in Electricity 1 Use of
... A voltmeter is used to measure the potential difference (p.d.) between two points in a circuit. The SI unit for p.d. is volt (V). When connected directly across a battery alone, the voltmeter measures the battery’s electromotive force (e.m.f.). An ideal voltmeter has an infinite resistance, so no cu ...
... A voltmeter is used to measure the potential difference (p.d.) between two points in a circuit. The SI unit for p.d. is volt (V). When connected directly across a battery alone, the voltmeter measures the battery’s electromotive force (e.m.f.). An ideal voltmeter has an infinite resistance, so no cu ...
ST7540 FSK powerline transceiver design guide for AMR
... Figure 32. Scheme of the connector for the EVALCOMMBOARD . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Figure 33. Typical waveforms at 230 Vac: open load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Figure 34. Typical waveforms at 230 Vac: full load . . . . ...
... Figure 32. Scheme of the connector for the EVALCOMMBOARD . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Figure 33. Typical waveforms at 230 Vac: open load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Figure 34. Typical waveforms at 230 Vac: full load . . . . ...
MPA Gold Manual
... The HPF is a single tuned High Pass Filter that is frequency tunable. The input signal can be filtered to remove “pops” or other extraneous low frequency information. This control moves the rolloff frequency from 10 Hz (fully CCW) to 200 Hz (fully CW). Since it is single tuned, it preserves some low ...
... The HPF is a single tuned High Pass Filter that is frequency tunable. The input signal can be filtered to remove “pops” or other extraneous low frequency information. This control moves the rolloff frequency from 10 Hz (fully CCW) to 200 Hz (fully CW). Since it is single tuned, it preserves some low ...
Shannon Optimization Project
... microelectronic systems in the form of battery life and bulky cooling fans. These problems continue to grow as leakage power becomes the predominant form of power consumption below 45 nm. A design tool was developed to synthesize combinatorial logic with reduced power consumption using hypergraph pa ...
... microelectronic systems in the form of battery life and bulky cooling fans. These problems continue to grow as leakage power becomes the predominant form of power consumption below 45 nm. A design tool was developed to synthesize combinatorial logic with reduced power consumption using hypergraph pa ...
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)
... technique we obtain 4.57nW power i.e. 64.21 % power reduction and then in another case we apply only MTCMOS technique in this we attain 4.35nW power i.e. 65.93% power reduction and lastly when we combine both the techniques and apply on this circuit we obtain 1.33nW power i.e. overall power reductio ...
... technique we obtain 4.57nW power i.e. 64.21 % power reduction and then in another case we apply only MTCMOS technique in this we attain 4.35nW power i.e. 65.93% power reduction and lastly when we combine both the techniques and apply on this circuit we obtain 1.33nW power i.e. overall power reductio ...
12 Multimeter - Fluke Meter Repair Fluke Networks Repair
... Do not use the meter if the meter or test leads look damaged, or if you suspect that the meter is not operating properly. Turn off power to the circuit under test before cutting, unsoldering, or breaking the circuit. Small amounts of current can be dangerous. Do not apply more than 600 V rms between ...
... Do not use the meter if the meter or test leads look damaged, or if you suspect that the meter is not operating properly. Turn off power to the circuit under test before cutting, unsoldering, or breaking the circuit. Small amounts of current can be dangerous. Do not apply more than 600 V rms between ...