DAC5652-EP - Texas Instruments
... Operating with update rates of up to 200 MSPS, the DAC5652 offers exceptional dynamic performance, tight gain, and offset matching characteristics that make it suitable in either I/Q baseband or direct IF communication applications. Each DAC has a high impedance differential current output, suitable ...
... Operating with update rates of up to 200 MSPS, the DAC5652 offers exceptional dynamic performance, tight gain, and offset matching characteristics that make it suitable in either I/Q baseband or direct IF communication applications. Each DAC has a high impedance differential current output, suitable ...
XCL211/XCL212Series
... (XCL211) or automatic PWM/PFM switching control (XCL212) can be selected. The XCL211 series has a fixed frequency, enabling the suppression of output ripple. The XCL212 series achieves high efficiency while holding down output ripple across the full range of loads, from light to heavy, enabling the ...
... (XCL211) or automatic PWM/PFM switching control (XCL212) can be selected. The XCL211 series has a fixed frequency, enabling the suppression of output ripple. The XCL212 series achieves high efficiency while holding down output ripple across the full range of loads, from light to heavy, enabling the ...
Power Supply Measurement and Analysis
... ON time as well as the high voltages that occur during the OFF time. To capture this signal, the oscilloscopes vertical range would be set at 100 volts per division. At this setting, the oscilloscope will accept voltages up to 1000 V; thus the 700 V signal can be acquired without overdriving the osc ...
... ON time as well as the high voltages that occur during the OFF time. To capture this signal, the oscilloscopes vertical range would be set at 100 volts per division. At this setting, the oscilloscope will accept voltages up to 1000 V; thus the 700 V signal can be acquired without overdriving the osc ...
Lecture 40
... (Sum of currents entering node) (Sum of currents leaving node) = 0 q = charge stored at node is zero. If charge is stored, for example in a capacitor, then the capacitor is a branch and the charge is stored there NOT at the node. ...
... (Sum of currents entering node) (Sum of currents leaving node) = 0 q = charge stored at node is zero. If charge is stored, for example in a capacitor, then the capacitor is a branch and the charge is stored there NOT at the node. ...
MAX8620Y µPMIC for Microprocessors or DSPs in Portable Equipment General Description
... current is guaranteed up to 500mA. When the step-down converter output voltage falls below the regulation threshold, the error comparator begins a switching cycle by turning the high-side pFET switch on. This switch remains on until the minimum ontime (tON) expires and the output voltage is in regul ...
... current is guaranteed up to 500mA. When the step-down converter output voltage falls below the regulation threshold, the error comparator begins a switching cycle by turning the high-side pFET switch on. This switch remains on until the minimum ontime (tON) expires and the output voltage is in regul ...
LT1719 - 4.5ns Single/Dual Supply 3V/5V Comparator with Rail-to-Rail Output
... maximum currents noted. External input protection circuitry is only needed if currents would otherwise exceed these absolute maximums. The internal catch diodes can conduct current up to these rated maximums without latchup, even when the supply voltage is at the absolute maximum rating. The LT1719 ...
... maximum currents noted. External input protection circuitry is only needed if currents would otherwise exceed these absolute maximums. The internal catch diodes can conduct current up to these rated maximums without latchup, even when the supply voltage is at the absolute maximum rating. The LT1719 ...
SA-360 - Carson Manufacturing
... this siren a relatively simple project even for the most inexperienced installer. ...
... this siren a relatively simple project even for the most inexperienced installer. ...
TDA8953 2 × 210 W class-D power amplifier
... After a fixed period of 100 ms, the amplifier will attempt to switch on again, but will fail if the output current still exceeds the OCP threshold. The amplifier will continue trying to switch on every 100 ms. The average power dissipation will be low in this situation because the duty cycle is shor ...
... After a fixed period of 100 ms, the amplifier will attempt to switch on again, but will fail if the output current still exceeds the OCP threshold. The amplifier will continue trying to switch on every 100 ms. The average power dissipation will be low in this situation because the duty cycle is shor ...
4 Set-up - FabLab Web
... The series TRM amplifiers are four-quadrant power amplifiers for permanent-field DC motors, that means that acceleration and braking is possible in both directions. To enable this, a 2.2-fold or triple continuous current is available for a certain time (about 2.5 seconds) depending on the version. F ...
... The series TRM amplifiers are four-quadrant power amplifiers for permanent-field DC motors, that means that acceleration and braking is possible in both directions. To enable this, a 2.2-fold or triple continuous current is available for a certain time (about 2.5 seconds) depending on the version. F ...
WBO2 Meter Slim Manual Wide Band O2 Sensor display
... Whenever the sensor is installed in the exhaust and the engine is running, the sensor MUST be connected to FuelTech WB-O2 Slim, which also needs to be in operation. That is to prevent the equipment from being rapidly damaged from exposure to the exhaust gas without heating control. ...
... Whenever the sensor is installed in the exhaust and the engine is running, the sensor MUST be connected to FuelTech WB-O2 Slim, which also needs to be in operation. That is to prevent the equipment from being rapidly damaged from exposure to the exhaust gas without heating control. ...
AD8627
... The AD862x is one of the smallest and most economical JFETs offered. It has true single-supply capability and has an input voltage range that extends below the negative rail, allowing the part to accommodate input signals below ground. The rail-to-rail output of the AD862x provides the maximum dynam ...
... The AD862x is one of the smallest and most economical JFETs offered. It has true single-supply capability and has an input voltage range that extends below the negative rail, allowing the part to accommodate input signals below ground. The rail-to-rail output of the AD862x provides the maximum dynam ...
AP3436/A Description Pin Assignments
... pulse-skipping modulation (PSM) mode depending on the different load conditions. The device can operate at typical 1.25MHz fixed switching frequency under heavy load condition. At light load, the regulator enters a PSM mode to minimize the switching loss by reducing the switching frequency. The AP34 ...
... pulse-skipping modulation (PSM) mode depending on the different load conditions. The device can operate at typical 1.25MHz fixed switching frequency under heavy load condition. At light load, the regulator enters a PSM mode to minimize the switching loss by reducing the switching frequency. The AP34 ...
microcomputer-controlled devices for human implantation
... disorders that until now have been treated only poorly if at all. A first application of microcomputers implanted in humans is the Programmable Implantable Medication System (PIMS), currently under development at APL. This device has characteristics very similar to those of an orbiting spacecraft. T ...
... disorders that until now have been treated only poorly if at all. A first application of microcomputers implanted in humans is the Programmable Implantable Medication System (PIMS), currently under development at APL. This device has characteristics very similar to those of an orbiting spacecraft. T ...
P82B715 1. General description I
... The P82B715 is a bipolar IC intended for application in I2C-bus and derivative bus systems. While retaining all the operating modes and features of the I2C-bus it permits extension of the practical separation distance between components on the I2C-bus by buffering both the data (SDA) and the clock ( ...
... The P82B715 is a bipolar IC intended for application in I2C-bus and derivative bus systems. While retaining all the operating modes and features of the I2C-bus it permits extension of the practical separation distance between components on the I2C-bus by buffering both the data (SDA) and the clock ( ...
Energy Management
... This general purpose threephase energy meter is suitable for both active and reactive energy metering for cost allocation but also for main electrical parameter measurement and retransmission (transducer function). Housing for DINrail mounting with IP50 ...
... This general purpose threephase energy meter is suitable for both active and reactive energy metering for cost allocation but also for main electrical parameter measurement and retransmission (transducer function). Housing for DINrail mounting with IP50 ...
PURE SINE WAVE INVERTER FOR HOUSE BACKUP
... consumption because the switching devices are almost always off (low current means low power) or hard-on (low voltage drop means low power). Common circuits that utilize this feature include switched-mode power supplies, Class D audio power amplifiers, power inverters and motor drivers. Frequently, ...
... consumption because the switching devices are almost always off (low current means low power) or hard-on (low voltage drop means low power). Common circuits that utilize this feature include switched-mode power supplies, Class D audio power amplifiers, power inverters and motor drivers. Frequently, ...
SN75LVCP412CD 数据资料 dataSheet 下载
... Cable detect mode (for this mode to be active PS and EN must be tied H via a 4.7kΩ or both pins left as NC. Device must be placed < 2" (or <5cm) from eSATA connector). To use this feature CH 1 input must be connected to SATA host while CH 2 input to eSATA connector. After power up device sets CD = 0 ...
... Cable detect mode (for this mode to be active PS and EN must be tied H via a 4.7kΩ or both pins left as NC. Device must be placed < 2" (or <5cm) from eSATA connector). To use this feature CH 1 input must be connected to SATA host while CH 2 input to eSATA connector. After power up device sets CD = 0 ...
a AN-420 APPLICATION NOTE •
... users ponder the layout of their own board, they might consider using the ground planes to develop a controlled impedance with its associated signal layers. This is required if fast edge rates and/or long trace lengths are present. Propagation time and line loading will become a concern under these ...
... users ponder the layout of their own board, they might consider using the ground planes to develop a controlled impedance with its associated signal layers. This is required if fast edge rates and/or long trace lengths are present. Propagation time and line loading will become a concern under these ...
BD8306MUV
... The condition for feedback system stability under negative feedback is as follows: - Phase delay must be 135 °or lower when gain is 1 (0 dB) (Phase margin is 45° or higher) Since DC/DC converter application is sampled according to the switching frequency, the fGBW of the whole system (frequency at w ...
... The condition for feedback system stability under negative feedback is as follows: - Phase delay must be 135 °or lower when gain is 1 (0 dB) (Phase margin is 45° or higher) Since DC/DC converter application is sampled according to the switching frequency, the fGBW of the whole system (frequency at w ...
Basics
... . The transfer function of a system submitted to a current perturbation is the impedance . There are two ways to show impedance data : Bode and Nyquist . It is easy to switch from one representation to the other. . Impedance data can be interpreted using EC-Lab Z Sim and Z Fit. . Electrical circuits ...
... . The transfer function of a system submitted to a current perturbation is the impedance . There are two ways to show impedance data : Bode and Nyquist . It is easy to switch from one representation to the other. . Impedance data can be interpreted using EC-Lab Z Sim and Z Fit. . Electrical circuits ...
RT FLOW RATE TOTALISER - Southeastern Automation
... 1) To display rate for input frequencies below 0.3hz, for example setting the cut-off at 0.1Hz the rate will continue to display for input frequencies as low as 0.1Hz (one pulse every 10 seconds), such conditions often apply to flowmeters with low resolution pulse outputs (low frequency) or flowmete ...
... 1) To display rate for input frequencies below 0.3hz, for example setting the cut-off at 0.1Hz the rate will continue to display for input frequencies as low as 0.1Hz (one pulse every 10 seconds), such conditions often apply to flowmeters with low resolution pulse outputs (low frequency) or flowmete ...