• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
14-Output Clock Generator with Integrated 2.0 GHz VCO AD9516-3
14-Output Clock Generator with Integrated 2.0 GHz VCO AD9516-3

... LVPECL power supply can be from 2.5 V to 3.3 V (nominal). The AD9516-3 is specified for operation over the standard industrial range of −40°C to +85°C. ...
Alpha Continuity: 6K / 10K
Alpha Continuity: 6K / 10K

... aberrations experienced on Utility power lines today. It is your insurance for reliable, clean and stable voltage supply. It is worth taking care to install the system correctly and to have it maintained correctly by your regional Alpha service center (see chapter 8). ...
power supplies
power supplies

... DESCRIPTION The 694 Series of industrial-grade multi-tap stepdown voltage transformers with manual resettable current-limiting secondary circuit breakers is ideal for use in temperature control systems. These UL listed transformers provide 24 VAC control voltage from a 120-480 VAC primary supply. Th ...
Noise in Microwave Systems Package
Noise in Microwave Systems Package

... turns out that the antenna noise temperature in this case is simply equal to the physical temperature at the Earth’s surface! Of course, this temperature changes somewhat, but expressed in degrees Kelvin (i.e., with respect to absolute zero) this change is small. Thus, radio engineers typically assu ...
X - IBIS Open Forum
X - IBIS Open Forum

... extensions in later versions. The data in these sections are contained in .ibs files. Section 7 describes the package model format of IBIS Version 2.1 and a subsequent extension. Package models can be formatted within .ibs files or can be formatted (along with the Section file header keywords) as .p ...
Stakeholder Comment and Rationale Form  AESO AUTHORITATIVE DOCUMENT PROCESS Stakeholder Consultation Draft
Stakeholder Comment and Rationale Form AESO AUTHORITATIVE DOCUMENT PROCESS Stakeholder Consultation Draft

... interval, a pool participant submission to sell: (i) electric energy or dispatch down service and includes all of the operating blocks the pool participant uses for that submission; or (ii) operating reserves to ...
Diagnostic Repair Manual - Generator
Diagnostic Repair Manual - Generator

SUNNY BOY 3000-US / 3800-US / 4000-US - Installation
SUNNY BOY 3000-US / 3800-US / 4000-US - Installation

... its distributors or dealers nor SMA Solar Technology Canada Inc. nor its distributors or dealers shall be liable for any indirect, incidental, or consequential damages under any circumstances. (The exclusion of implied warranties may not apply in all cases under some statutes, and thus the above exc ...
Generator Protection
Generator Protection

UPLC-II™ - Ametek Power Instruments
UPLC-II™ - Ametek Power Instruments

document
document

... SYNC, which is an output from synchronizer in Fig. 3, rises as it is synchronized with the second falling edge of the VCO after the STOP arrives. The inputs for the TDA are STOP and SYNC, and the time difference between STOP and SYNC is less than 1.5 clock cycles of the VCO because the synchronizer ...
model 6400a sulfur dioxide analyzer
model 6400a sulfur dioxide analyzer

... 9.1.1 Fault Diagnosis with TEST Variables................................................................. 9-3 9.1.2 Fault Diagnosis with WARNING Messages ....................................................... 9-9 9.1.3 Fault Diagnosis using DIAGNOSTIC Mode ......................................... ...
Analog value processing
Analog value processing

TBU Industrial App Note V3
TBU Industrial App Note V3

... voltage levels are selected to be compatible with most low voltage GDT and MOV. After the surge TBU resets. A TBU resets when the voltage across the TBU falls to the Vreset level. TBU will always reset on lines which have no DC bias or have DC bias below Vreset (such as unpowered signal lines). If t ...
- Free Documents
- Free Documents

... No license is granted, implied or otherwise, under any patent or patent rights of VIA Technologies. VIA Technologies makes no warranties, implied or otherwise, in regard to this document and to the products described in this document. The information provided by this document is believed to be accur ...
AMD Functional Data Sheet, 940 Pin Package (public)
AMD Functional Data Sheet, 940 Pin Package (public)

... or otherwise, to any intellectual property rights is granted by this publication. Except as set forth in AMD’s Standard Terms and Conditions of Sale, AMD assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limited to, the implie ...
ICD PDN Planner Help Guide
ICD PDN Planner Help Guide

... A. Select the DDR2 1V8 PDN TAB. B. Select the stackup used and pick the power plane to be analyzed – the plane above and below. Fill in the Plane variables: The X, Y dimensions or area of the plane. If for instance we are using DDR2 devices, then the plane area may be very small – something in th ...
“Remedial Action Scheme” Definition Development
“Remedial Action Scheme” Definition Development

... The existing definition also lacks clarity in the actions stipulated as characteristics of an SPS or RAS. The actions  listed in the definition are so broad that the definition may unintentionally include schemes whose purpose is not  expressly related to preserving system reliability in response to ...
instruction manual cs-7b
instruction manual cs-7b

... A solid state digital phase angle meter is incorporated to measure the phase relationship between the various outputs of the test set and either an external reference current or an external reference potential. In addition, the phase angle meter can be used independently to measure the phase relatio ...
NI PXI-5114 Calibration Procedure
NI PXI-5114 Calibration Procedure

... Calibrating the NI 5114 requires installing NI-SCOPE version 2.9 or later on the calibration system. You can download NI-SCOPE from the Instrument Driver Network at ni.com/idnet. NI-SCOPE supports programming the Self-Calibration Procedures section in a number of programming languages. However, only ...
MAX3160E/MAX3161E/MAX3162E ±15kV ESD-Protected, +3.0V to +5.5V, 10nA, RS-232/RS-485/RS-422 Multiprotocol Transceivers General Description
MAX3160E/MAX3161E/MAX3162E ±15kV ESD-Protected, +3.0V to +5.5V, 10nA, RS-232/RS-485/RS-422 Multiprotocol Transceivers General Description

... electrostatic discharge (ESD) protection. All of the transmitter outputs and receiver inputs are protected to ±15kV using the Human Body Model. All devices incorporate a proprietary low-dropout transmitter output stage, and an on-board dual charge pump to allow RS-232- and RS-485-/RS-422-compliant p ...
C524, C524i Elliptical Fitness Crosstrainer
C524, C524i Elliptical Fitness Crosstrainer

... log entry shows the log position, the stride count when the error occurred and the hour meter when the error occurred. For example; 1 ER21 123456 STR 45678 HRS. The error log can record up to ten error conditions. The error code in position one will be the most recent error and the error in position ...
System Basis Chip with Integrated LIN and Voltage Regulator
System Basis Chip with Integrated LIN and Voltage Regulator

... Product parametric performance is indicated in the Electrical Characteristics for the listed test conditions, unless otherwise noted. Product performance may not be indicated by the Electrical Characteristics if operated under different conditions. 6. In case LIN bus capacitor of at least 82 pF is n ...
Trans-Impedance Amplifier (TIA)
Trans-Impedance Amplifier (TIA)

... the current component state. Then it calls the TIA_Stop() function and calls TIA_SaveConfig() to save the hardware configuration. Call the TIA_Sleep() function before calling the CyPmSleep() or the CyPmHibernate() function. Refer to the PSoC Creator System Reference Guide for more information about ...
AN11267 EMC and system level ESD design guidelines for LCD
AN11267 EMC and system level ESD design guidelines for LCD

... ElectroMagnetic Compatibility (EMC) and ElectroStatic Discharge (ESD) immunity must be considered in the early design phase of a system. This is also true for the application of liquid crystal displays and the accompanying drivers. If ignored, problems encountered later during testing or in the fiel ...
< 1 ... 11 12 13 14 15 16 17 18 19 ... 1306 >

Immunity-aware programming

When writing firmware for an embedded system, immunity-aware programming refers to programming techniques which improve the tolerance of transient errors in the program counter or other modules of a program that would otherwise lead to failure. Transient errors are typically caused by single event upsets, insufficient power, or by strong electromagnetic signals transmitted by some other ""source"" device.Immunity-aware programming is an example of defensive programming and EMC-aware programming. Although most of these techniques apply to the software in the ""victim"" device to make it more reliable, a few of these techniques apply to software in the ""source"" device to make it emit less unwanted noise.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report