Introduction to KaleidaGraph
... want to plot the resistance of a component when your raw data is voltage and current. The data table can be edited just like columns of numbers in a spreadsheet. You can add, multiply, divide, etc., to generate a new column of numbers. In Kaleidagraph the columns are labeled c0, c1, c2, and so on. I ...
... want to plot the resistance of a component when your raw data is voltage and current. The data table can be edited just like columns of numbers in a spreadsheet. You can add, multiply, divide, etc., to generate a new column of numbers. In Kaleidagraph the columns are labeled c0, c1, c2, and so on. I ...
SatNet S2020 DVB-RCS VSAT Terminals
... DVB-RCS compliant terminals. These rack-mountable units have a slim 1U form factor. The SatNet S2020 offers simple connectivity to your corporate LAN and is one of the fastest satellite interactive terminals available today. A truly corporate solution, the SatNet S2020 is designed to provide enterpr ...
... DVB-RCS compliant terminals. These rack-mountable units have a slim 1U form factor. The SatNet S2020 offers simple connectivity to your corporate LAN and is one of the fastest satellite interactive terminals available today. A truly corporate solution, the SatNet S2020 is designed to provide enterpr ...
Document
... • Stays high until Threshold rises above 2/3 Vcc, then switches low and lets current flow in through Discharge pin • Stays low until Trigger falls below 1/3 Vcc, then switches high and stops letting current flow in through Discharge pin ...
... • Stays high until Threshold rises above 2/3 Vcc, then switches low and lets current flow in through Discharge pin • Stays low until Trigger falls below 1/3 Vcc, then switches high and stops letting current flow in through Discharge pin ...
Open circuit test
... excitation branch. Thus the wattmeter measures only the iron loss. Since the secondary of the transformer is open, the primary draws only no load current. This no load current is negligible. As the copper losses depend on current they can be neglected. Current, voltage and power are measured at the ...
... excitation branch. Thus the wattmeter measures only the iron loss. Since the secondary of the transformer is open, the primary draws only no load current. This no load current is negligible. As the copper losses depend on current they can be neglected. Current, voltage and power are measured at the ...
Lab07_La_Juan
... Reading error is common error. In the experiment, the data is read from the device. The device shows a variant number. Therefore the recorded data is an estimate or average of the fluctuation quantity. The device used in the experiment also contributed to errors. Each device has a deviation, so it ...
... Reading error is common error. In the experiment, the data is read from the device. The device shows a variant number. Therefore the recorded data is an estimate or average of the fluctuation quantity. The device used in the experiment also contributed to errors. Each device has a deviation, so it ...
3 ELECTRICAL SAFETY DEVICES – SAFETY MOMENT
... longer overloaded before resetting the circuit breaker). - If the circuit will not reset by turning all the way off and back on, contact an electrician. 2. Surge Protector: - Designed to protect electrical devices from voltage spikes (ex. a lightning strike). - Attempts to block the voltage supplied ...
... longer overloaded before resetting the circuit breaker). - If the circuit will not reset by turning all the way off and back on, contact an electrician. 2. Surge Protector: - Designed to protect electrical devices from voltage spikes (ex. a lightning strike). - Attempts to block the voltage supplied ...
SL MD-220 Optical Transmittance Analyzer SPECIFICATIONS
... fiber optic sensors, monitors the amount of light transmitted through the sensors and detects small changes caused by loads applied to the sensors. With its advanced circuitry, the interface can detect a load on a sensor for as long as it is applied to the sensor. The MD-220 incorporates a TI MSP-43 ...
... fiber optic sensors, monitors the amount of light transmitted through the sensors and detects small changes caused by loads applied to the sensors. With its advanced circuitry, the interface can detect a load on a sensor for as long as it is applied to the sensor. The MD-220 incorporates a TI MSP-43 ...
MDT-ASD: LVDS properties
... Was any attention paid to minimizing impact of single point failures? Were any techniques used to enhance reliability (multiple vias, wider than nominal widths, clearances, etc.)? Is there data on chip lifetime from the manufacturer? Has the process been used in a similar way for other circuits? How ...
... Was any attention paid to minimizing impact of single point failures? Were any techniques used to enhance reliability (multiple vias, wider than nominal widths, clearances, etc.)? Is there data on chip lifetime from the manufacturer? Has the process been used in a similar way for other circuits? How ...
Data Acquisition System Design
... The opposite of analog to digital conversion is digital to analog (D/A) conversion. This operation converts digital information into analog voltage or current. D/A devices allow the computer to control real-world events. Analog output signals may directly control process equipment. The process can g ...
... The opposite of analog to digital conversion is digital to analog (D/A) conversion. This operation converts digital information into analog voltage or current. D/A devices allow the computer to control real-world events. Analog output signals may directly control process equipment. The process can g ...
dhaval_sdcard_05282013
... being used and the size of the partition; typically cluster sizes lie somewhere between 2 KB and 32 KB. Each file may occupy one or more of these clusters depending on its size; thus, a file is represented by a chain of these clusters (referred to as a singly linked list). However these clusters are ...
... being used and the size of the partition; typically cluster sizes lie somewhere between 2 KB and 32 KB. Each file may occupy one or more of these clusters depending on its size; thus, a file is represented by a chain of these clusters (referred to as a singly linked list). However these clusters are ...
Physics 536 - Assignment #6 - Due March 19
... which has IDSS ≈ 20 mA and VP = −4 V. The voltage source, Vin (t) has a peak-to-peak amplitude of 10 mV and a frequency of 10 kHz, modelled using VIN 5 0 DC 0 SIN(0 0.01V 10KHZ) and where R1 = 10 kΩ represents the large output impedance of a non-ideal voltage source, such as the element of a microph ...
... which has IDSS ≈ 20 mA and VP = −4 V. The voltage source, Vin (t) has a peak-to-peak amplitude of 10 mV and a frequency of 10 kHz, modelled using VIN 5 0 DC 0 SIN(0 0.01V 10KHZ) and where R1 = 10 kΩ represents the large output impedance of a non-ideal voltage source, such as the element of a microph ...
326/327 Series - Time Delay Relays - Struthers-Dunn
... XAX (SPDT) - (1 form C) XBX (DPDT) - (2 form C) XCX (3PDT) - (3 form C) ...
... XAX (SPDT) - (1 form C) XBX (DPDT) - (2 form C) XCX (3PDT) - (3 form C) ...
Title : Intelligent battery charger
... • The project was a proposal from the PEP program carried out at Blue Tree. • The Proposal : Intelligent Back-up Battery charger attached to a Dry trailer system. • The circuit is expected to : – Integrate with the R:COM system – Provide an interface to the tractor’s power source (Battery) when the ...
... • The project was a proposal from the PEP program carried out at Blue Tree. • The Proposal : Intelligent Back-up Battery charger attached to a Dry trailer system. • The circuit is expected to : – Integrate with the R:COM system – Provide an interface to the tractor’s power source (Battery) when the ...
STM32_Chap4_USART - Calculateur-Emb
... Transmitter (Tx) - converts data from parallel to serial ...
... Transmitter (Tx) - converts data from parallel to serial ...
Datasheet - UNIPOWER
... Operation of the power supplies can be accomplished locally via the front panel controls or remotely via the rear panel control connector J4. Three additional jacks (J5A, J5B and J5c) are provided for interface to external source modules. J-4 is a 25 Pin D connector while each of the J-5 connectors ...
... Operation of the power supplies can be accomplished locally via the front panel controls or remotely via the rear panel control connector J4. Three additional jacks (J5A, J5B and J5c) are provided for interface to external source modules. J-4 is a 25 Pin D connector while each of the J-5 connectors ...
Handout - cyphynets
... PRELAB 1. Look up the data sheet of the integrated circuit (IC) HA17741 or UA741CN from the internet. Draw its layout as shown in Fig. 3. 2. What is the gain of an ideal op‐amp? 3. Draw the output waveform for circuit in Fig. 5 if a 1 Hz sinusoidal signal is fed at the input of the ...