INTEGRATED CIRCUITS
... switched on as long as a “1” is output; the weak pullup devices are not used. The output can source up to 3.2mA in this configuration. In open-drain mode only the strong pull-down transistor is available, no pull-up devices are involved at all. The I²C-bus requires special open-drain drivers. An un- ...
... switched on as long as a “1” is output; the weak pullup devices are not used. The output can source up to 3.2mA in this configuration. In open-drain mode only the strong pull-down transistor is available, no pull-up devices are involved at all. The I²C-bus requires special open-drain drivers. An un- ...
Bourns® Chip Resistors
... *RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011. Specifications are subject to change without notice. Users should verify actual device performance in their specific applications. The device characteristics and parameters in this data sheet can and do ...
... *RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011. Specifications are subject to change without notice. Users should verify actual device performance in their specific applications. The device characteristics and parameters in this data sheet can and do ...
MC1458
... enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products ...
... enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products ...
800 A sun volt page
... can not be ramped up slowly, but must be applied instantly to at least the maximum pick-up voltage. Otherwise, the contactor will not pick up. ...
... can not be ramped up slowly, but must be applied instantly to at least the maximum pick-up voltage. Otherwise, the contactor will not pick up. ...
CD4541B (Rev. E) - Texas Instruments
... Input Voltage Range, All Inputs . . . . . . . . . . . . . -0.5V to VDD +0.5V DC Input Current, Any One Input . . . . . . . . . . . . . . . . . . . . . ±10mA ...
... Input Voltage Range, All Inputs . . . . . . . . . . . . . -0.5V to VDD +0.5V DC Input Current, Any One Input . . . . . . . . . . . . . . . . . . . . . ±10mA ...
encoder and decoder
... and data pins in different packages so as to pair with the 2 12 series of encoders. The decoders receive data that are transmitted by an encoder and interpret the first N bits of code period as addresses and the last 12_N bits as data, where N is the address code number. A signal on the DIN pin acti ...
... and data pins in different packages so as to pair with the 2 12 series of encoders. The decoders receive data that are transmitted by an encoder and interpret the first N bits of code period as addresses and the last 12_N bits as data, where N is the address code number. A signal on the DIN pin acti ...
611 Transients in Power Systems
... ECE 611: Electrical Transients in Power Systems Description: Transient performance of power systems with lumped properties, interruption of arcs, restriking voltage, re-ignition inertia effects, switching of rotational systems, magnetic saturation in stationary networks, harmonic oscillations, satur ...
... ECE 611: Electrical Transients in Power Systems Description: Transient performance of power systems with lumped properties, interruption of arcs, restriking voltage, re-ignition inertia effects, switching of rotational systems, magnetic saturation in stationary networks, harmonic oscillations, satur ...
Digital Storage Oscilloscopes
... real time while viewing the entire captured waveform simultaneously. ...
... real time while viewing the entire captured waveform simultaneously. ...
CN3240 : 1/4 DIN Independent Dual Channel Temperature
... output per channel Relay: N.O. contact rated 8 A at 120/250 Vac or 5 A at 30 Vdc dc Pulse: Transistor output of 20 Vdc at 40 mA, jumper selectable ...
... output per channel Relay: N.O. contact rated 8 A at 120/250 Vac or 5 A at 30 Vdc dc Pulse: Transistor output of 20 Vdc at 40 mA, jumper selectable ...
EBC-Z510-G - SFF-SIG
... Wireless - The EBC-Z5xx is shipped with an empty MiniPCIe socket so that a user can install their own card from a 3rd party vendor. Normally wireless cards are automatically recognized by operating systems such as Windows® XP. Also, the individual miniPCIe card manufacturer will typically have drive ...
... Wireless - The EBC-Z5xx is shipped with an empty MiniPCIe socket so that a user can install their own card from a 3rd party vendor. Normally wireless cards are automatically recognized by operating systems such as Windows® XP. Also, the individual miniPCIe card manufacturer will typically have drive ...
Series Circuit Characteristics Parallel Circuit Characteristics
... 2. Each branch has an individual current path. I can calculate the current using Ohm's Law if I know the voltage across the component and the resistance. 3. Kirchoff's Current Law Applies. This means that the sum of all the voltage sources is equal to the sum of all the voltage drops or I T = I 1 + ...
... 2. Each branch has an individual current path. I can calculate the current using Ohm's Law if I know the voltage across the component and the resistance. 3. Kirchoff's Current Law Applies. This means that the sum of all the voltage sources is equal to the sum of all the voltage drops or I T = I 1 + ...
California Rule 21 LVRT - Northwest Solar Communities
... Trip: Cease to energize or disconnect from the Area EPS due to an Area EPS disturbance. Following a trip, the IDER must delay re-energization or reconnection for a preset period of time once the voltage and frequency of the Area EPS are within normal ranges (voltage within ANSI C84.1-1995 Table 1 Ra ...
... Trip: Cease to energize or disconnect from the Area EPS due to an Area EPS disturbance. Following a trip, the IDER must delay re-energization or reconnection for a preset period of time once the voltage and frequency of the Area EPS are within normal ranges (voltage within ANSI C84.1-1995 Table 1 Ra ...
1 - Marine Institute
... b) Frequency of voltage, current and power waves, (159Hz, fp = 318Hz) c) Period, and (6.28mS) d) Two times at which the instantaneous voltage is +80V. (.927mS, 2.21mS) (Note: Find 2 times, t1 before the peak and t2 after the peak) ...
... b) Frequency of voltage, current and power waves, (159Hz, fp = 318Hz) c) Period, and (6.28mS) d) Two times at which the instantaneous voltage is +80V. (.927mS, 2.21mS) (Note: Find 2 times, t1 before the peak and t2 after the peak) ...
understanding low Voltage measurements
... All other trademarks and trade names are the property of their respective companies. ...
... All other trademarks and trade names are the property of their respective companies. ...
DataCell Military - Merlin Equipment
... DataCell will operate on both 12V and 24V battery systems. Simply choose the part number required for the number of battery banks you want to monitor. Multiple battery bank DataCell’s are capable of monitoring several battery types and voltages. ...
... DataCell will operate on both 12V and 24V battery systems. Simply choose the part number required for the number of battery banks you want to monitor. Multiple battery bank DataCell’s are capable of monitoring several battery types and voltages. ...
p130_holman_poster
... COTS SRAM-FPGA implementation of the digital controller Higher density, lower cost, and faster turn- ...
... COTS SRAM-FPGA implementation of the digital controller Higher density, lower cost, and faster turn- ...
Direct and Alternating Voltages, the Oscilloscope
... 6. Set the function generator to make a high-frequency (1.5 MHz) square wave and use the scope to measure the rise time. This is the time it takes the wave to go from 10% to 90% of its maximum amplitude. Measure also the corresponding fall time. 7. What is the use of the alternate and chop options? ...
... 6. Set the function generator to make a high-frequency (1.5 MHz) square wave and use the scope to measure the rise time. This is the time it takes the wave to go from 10% to 90% of its maximum amplitude. Measure also the corresponding fall time. 7. What is the use of the alternate and chop options? ...