Instrument Transformers
... • Available for voltage range from 72.5 kV up to 300 kV and full current range of 0.5 A up to 5,000 A • Comparably smaller footprint as a consequence of combining the voltage and current-sensing functions into one unit • Exceptional control of internal and external insulation stresses through ...
... • Available for voltage range from 72.5 kV up to 300 kV and full current range of 0.5 A up to 5,000 A • Comparably smaller footprint as a consequence of combining the voltage and current-sensing functions into one unit • Exceptional control of internal and external insulation stresses through ...
LATCHES AND FILP FLOPS
... The capacitance ratio is the ratio of the diode's capacitance at the minimum reverse voltage (largest C) to the diode's capacitance at the maximum reverse voltage (smallest C). Datasheets also include parameters such as maximum ratings for current, power, and temperature. Varactor Applications A maj ...
... The capacitance ratio is the ratio of the diode's capacitance at the minimum reverse voltage (largest C) to the diode's capacitance at the maximum reverse voltage (smallest C). Datasheets also include parameters such as maximum ratings for current, power, and temperature. Varactor Applications A maj ...
THE HIGH RESISTANCE GROUNDED POWER SYSTEM
... Severe flash hazard Main breaker may be required Loss of production Equipment damage High values of fault current Single-phase fault escalation into 3 phase fault is likely Creates problems on the primary system ...
... Severe flash hazard Main breaker may be required Loss of production Equipment damage High values of fault current Single-phase fault escalation into 3 phase fault is likely Creates problems on the primary system ...
ABB Kuhlman 34500 Volt Instrument Transformers
... - 1 Second Thermal/Mechanical Rating: Single Ratio (150x lnom), Dual Ratio (75x full winding Inom), 144kA max. * IC Approval AE-0600 Rev. 3 for 1200:5 MR. ...
... - 1 Second Thermal/Mechanical Rating: Single Ratio (150x lnom), Dual Ratio (75x full winding Inom), 144kA max. * IC Approval AE-0600 Rev. 3 for 1200:5 MR. ...
BD63710AEFV
... Motor’s drive current is flowing in it, so please wire in such a way that the wire is thick & short and has low impedance. Voltage VCC may have great fluctuation, so please arrange the bypass capacitor of about 100μ~470μF as close to the terminal as possible and adjust in such a way that the voltage ...
... Motor’s drive current is flowing in it, so please wire in such a way that the wire is thick & short and has low impedance. Voltage VCC may have great fluctuation, so please arrange the bypass capacitor of about 100μ~470μF as close to the terminal as possible and adjust in such a way that the voltage ...
Electrosurgery and Latex Gloves
... which transfers energy (electrons) to tissue. The term ‘Bovie’, a manufacturer’s trademark named after one of the early pioneers, Dr William T Bovie, is often used synonymously with the term Electrosurgery. The terms electrosurgery and electrocautery are also often used synonymously; however, this i ...
... which transfers energy (electrons) to tissue. The term ‘Bovie’, a manufacturer’s trademark named after one of the early pioneers, Dr William T Bovie, is often used synonymously with the term Electrosurgery. The terms electrosurgery and electrocautery are also often used synonymously; however, this i ...
AAT3175 数据资料DataSheet下载
... The AAT3175 is a low noise, constant frequency charge pump DC/DC converter that uses a tri-mode load switch (1X), fractional (1.5X), and doubling (2X) conversion to maximize efficiency for white LED flash applications. The AAT3175 is capable of driving up to three flash LEDs at 300mA total current f ...
... The AAT3175 is a low noise, constant frequency charge pump DC/DC converter that uses a tri-mode load switch (1X), fractional (1.5X), and doubling (2X) conversion to maximize efficiency for white LED flash applications. The AAT3175 is capable of driving up to three flash LEDs at 300mA total current f ...
AL8400 /AL8400Q Description Pin Assignments
... an external resistor RSET. The pass element is driven by the AL8400’s open collector OUT pin which allows the pass element to be either an NPN transistor or N-channel MOSFET. An external pull-up resistor, RB, is required to be connected from the OUT pin to VCC. This resistor supplies the output bias ...
... an external resistor RSET. The pass element is driven by the AL8400’s open collector OUT pin which allows the pass element to be either an NPN transistor or N-channel MOSFET. An external pull-up resistor, RB, is required to be connected from the OUT pin to VCC. This resistor supplies the output bias ...
Earth fault relays with separate toroids Vigirex Merlin Gerin
... I∆n/2 alarm threshold Vigirex type AP relays have an alarm threshold that warns of a non-critical degradation of the insulation, leaving time to carry out preventive maintenance. The alarm threshold is set automatically at In∆/2, where I∆/n is the residual operating current. The alarm is indicated b ...
... I∆n/2 alarm threshold Vigirex type AP relays have an alarm threshold that warns of a non-critical degradation of the insulation, leaving time to carry out preventive maintenance. The alarm threshold is set automatically at In∆/2, where I∆/n is the residual operating current. The alarm is indicated b ...
3.002 How are Neon Transformers different from the more
... Balanced Mid-Point Referenced Design (formerly balanced midpoint grounded) This is most commonly found in mid to higher voltage rated transformers and most 60 mA transformers. This is the only type transformer acceptable in a "mid-point return wired" system. The "balanced" neon transformer usually h ...
... Balanced Mid-Point Referenced Design (formerly balanced midpoint grounded) This is most commonly found in mid to higher voltage rated transformers and most 60 mA transformers. This is the only type transformer acceptable in a "mid-point return wired" system. The "balanced" neon transformer usually h ...
ABB circuit-breakers for direct current applications
... of a normal battery. The main difference is that with accumulator batteries the discharging/charging process is reversible: in fact, by using a DC generator, it is possible to restore the initial status of the electrodes which have been altered during discharge; such process cannot be carried out wi ...
... of a normal battery. The main difference is that with accumulator batteries the discharging/charging process is reversible: in fact, by using a DC generator, it is possible to restore the initial status of the electrodes which have been altered during discharge; such process cannot be carried out wi ...
Aalborg Universitet Multilevel Converters
... inserted capacitors. This method is used for the comparison in this paper and it referred as NLC. In order to achieve better approximation, reducing the error caused by rounding, one SM per arm should be inserted by using PWM technique. In this way the average voltage during an update period become ...
... inserted capacitors. This method is used for the comparison in this paper and it referred as NLC. In order to achieve better approximation, reducing the error caused by rounding, one SM per arm should be inserted by using PWM technique. In this way the average voltage during an update period become ...
Current Sensor ML20f - CMA
... The Current sensor ML20f is a general-purpose sensor to measure currents in AC and DC circuits in the range between -3 and +3 A. The sensor is equipped with two 4-mm banana plugs and two additional alligator clips are delivered with the sensor. The Current sensor should be placed in series with the ...
... The Current sensor ML20f is a general-purpose sensor to measure currents in AC and DC circuits in the range between -3 and +3 A. The sensor is equipped with two 4-mm banana plugs and two additional alligator clips are delivered with the sensor. The Current sensor should be placed in series with the ...
TT8U1
... Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM shall bear no respo ...
... Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM shall bear no respo ...
Zener Diode
... If the reverse-bias voltage magnitude is increased above a threshold (the specific value depends on the junction geometry and material parameters) one or the other (possibly even both concurrently) of two new phenomena occur. These phenomena, which are different from the junction phenomena described ...
... If the reverse-bias voltage magnitude is increased above a threshold (the specific value depends on the junction geometry and material parameters) one or the other (possibly even both concurrently) of two new phenomena occur. These phenomena, which are different from the junction phenomena described ...
basics of electronics lab manual i, ii semester
... visible. To accomplish these tasks, various electrical signals and voltages are required. The power supply block provides the voltages required by the cathode ray tube to generate and accelerate the electron beam, as well as to supply the required operating voltages for the other circuits of the osc ...
... visible. To accomplish these tasks, various electrical signals and voltages are required. The power supply block provides the voltages required by the cathode ray tube to generate and accelerate the electron beam, as well as to supply the required operating voltages for the other circuits of the osc ...
BD3925(H)
... Input pins of an IC are often connected to the gate of a MOS transistor. The gate has extremely high impedance and extremely low capacitance. If left unconnected, the electric field from the outside can easily charge it. The small charge acquired in this way is enough to produce a significant effect ...
... Input pins of an IC are often connected to the gate of a MOS transistor. The gate has extremely high impedance and extremely low capacitance. If left unconnected, the electric field from the outside can easily charge it. The small charge acquired in this way is enough to produce a significant effect ...
Mercury-arc valve
A mercury-arc valve or mercury-vapor rectifier or (UK) mercury-arc rectifier is a type of electrical rectifier used for converting high-voltage or high-current alternating current (AC) into direct current (DC). It is a type of cold cathode gas-filled tube, but is unusual in that the cathode, instead of being solid, is made from a pool of liquid mercury and is therefore self-restoring. As a result, mercury-arc valves were much more rugged, long-lasting and could carry much higher currents than most other types of gas discharge tube.Invented in 1902 by Peter Cooper Hewitt, mercury-arc rectifiers were used to provide power for industrial motors, electric railways, streetcars, and electric locomotives, as well as for radio transmitters and for high-voltage direct current (HVDC) power transmission. They were the primary method of high power rectification before the advent of semiconductor rectifiers, such as diodes, thyristors and gate turn-off thyristors (GTOs) in the 1970s.