• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
BD95602MUV
BD95602MUV

... This is the coil current limit setting pin. Set the resistor which is connected in between ground. ...
LM2594 datasheet
LM2594 datasheet

... The switching frequency is reduced when the second stage current limit is activated. The amount of reduction is determined by the severity of current overload. No diode, inductor or capacitor connected to output pin. Feedback pin removed from output and connected to 0V to force the output transistor ...
MOD II
MOD II

... circuit emf E. during inverter operation, load circuit emf when inverted to ac must be more than ac supply voltage. In other words, dc source voltage E must be more than inverter voltage V0 , only then power would flow from dc source to ac supply system. But in both converter and inverter modes, thy ...
MAX17126B Multi-Output Power Supplies with VCOM Amplifier EVALUATION KIT AVAILABLE
MAX17126B Multi-Output Power Supplies with VCOM Amplifier EVALUATION KIT AVAILABLE

LTC3857-1 - Low IQ, Dual, 2-Phase Synchronous Step
LTC3857-1 - Low IQ, Dual, 2-Phase Synchronous Step

... Each Controller. Forcing either of these pins below 1.26V shuts down that controller. Forcing both of these pins below 0.7V shuts down the entire LTC3857-1, reducing quiescent current to approximately 8μA. Do not float these pins. INTVCC (Pin 19): Output of the Internal Linear Low Dropout Regulator. ...
Lecture 4: Transformers
Lecture 4: Transformers

... Class web site: MyLamar ...
Power Delivery and Leakage Field Control Using an Adaptive
Power Delivery and Leakage Field Control Using an Adaptive

... but there are also several other advantages of this phased array WPT system. First, maximum efficiency can be achieved anywhere within a defined volume of space, regardless of the orientation or position of the receiver by optimizing the frequency, magnitude and phase of the various transmitters. Se ...
LT3759 - Wide Input Voltage Range Boost/SEPIC/Inverting Controller
LT3759 - Wide Input Voltage Range Boost/SEPIC/Inverting Controller

... The LT3759 uses a fixed frequency, current mode control scheme to provide excellent line and load regulation. Operation can be best understood by referring to the Block Diagram in Figure 1. The start of each oscillator cycle sets the SR latch (SR1) and turns on the external power MOSFET switch M1 th ...
AN3027 Application note How to design a transition-mode PFC pre-regulator
AN3027 Application note How to design a transition-mode PFC pre-regulator

... The front-end stage of conventional offline converters, typically consisting of a full-wave rectifier bridge with a capacitor filter, has an unregulated DC bus from the AC mains. The filter capacitor must be large enough to have a relatively low ripple superimposed on the DC level. This means that t ...
Chapter 2
Chapter 2

... “adjust” its impedance based on varying input voltages and loads (RL) to be able  to maintain its designated zener voltage.  Zener current will increase or decrease directly with voltage input changes.  The zener current will increase or decrease inversely with varying loads.  Again, the zener has a ...
MAX3171/MAX3173 +3.3V Multiprotocol 3Tx/3Rx Software-Selectable Control Transceivers General Description
MAX3171/MAX3173 +3.3V Multiprotocol 3Tx/3Rx Software-Selectable Control Transceivers General Description

... An internal charge pump and proprietary low-dropout transmitter output stage allow V.28, V.11, and V.10 compliant operation from a single +3.3V supply. A nocable mode is entered when all mode pins (M0, M1, and M2) are pulled high or left unconnected. In nocable mode, supply current decreases to 2mA ...
MAX17014 Low-Cost Multiple-Output Power Supply for LCD TVs General Description
MAX17014 Low-Cost Multiple-Output Power Supply for LCD TVs General Description

fvco VREF
fvco VREF

... to generate a second current for adjusting the control voltage to achieve a second lock condition; and control circuitry operable to couple the ?rst charge control circuit to the volt age controlled oscillator circuit until the ?rst lock condition is ...
MAX1692 Low-Noise, 5.5V-Input, PWM Step-Down Regulator General Description
MAX1692 Low-Noise, 5.5V-Input, PWM Step-Down Regulator General Description

Lightning Protection for Power Systems: A Primer
Lightning Protection for Power Systems: A Primer

... surge arrestor has a high impedance and therefore does not allow much current to flow through it. This keeps power consumption low under normal operating conditions. When a voltage surge occurs, however, the surge arrestor allows a large amount of current to flow, limiting the voltage across itself ...
Invertig 160DC Owner`s Manual
Invertig 160DC Owner`s Manual

MAX8790 Six-String White LED Driver with Active General Description
MAX8790 Six-String White LED Driver with Active General Description

MAX8790A Six-String White LED Driver with Active General Description
MAX8790A Six-String White LED Driver with Active General Description

... The MAX8790A is a high-efficiency driver for white lightemitting diodes (LEDs). It is designed for large liquidcrystal displays (LCDs) that employ an array of LEDs as the light source. A current-mode step-up controller drives up to six parallel strings of multiple series-connected LEDs. Each string ...
With Pre-Contacts Without Pre-Contacts
With Pre-Contacts Without Pre-Contacts

... - The inrush current peaks are reduced by the resistor wires - All contactors are provided with pre-contacts with snap function - The pre-contacts are opening after the main contacts are closed - The single controlled pre-contacts - as one block - are increasing the reliability against dust in the f ...
OPERATING MANUAL Model BD-80C High Frequency Corona
OPERATING MANUAL Model BD-80C High Frequency Corona

AN3027 Application note How to design a transition-mode PFC pre-regulator
AN3027 Application note How to design a transition-mode PFC pre-regulator

... The front-end stage of conventional offline converters, typically consisting of a full-wave rectifier bridge with a capacitor filter, has an unregulated DC bus from the AC mains. The filter capacitor must be large enough to have a relatively low ripple superimposed on the DC level. This means that t ...
ec1009 electron devices lab laboratory manual
ec1009 electron devices lab laboratory manual

... course teacher in-charge of both the sections. Habitually late students (i.e., students late more than 15 minutes more than once) will receive 10 point reductions in their grades for each occurrence following the first. 7. Reports Due Dates: Reports are due one week after completion of the correspon ...
Simultaneous Communication and Processor Voltage Scaling for Dynamic and
Simultaneous Communication and Processor Voltage Scaling for Dynamic and

... have been mapped and scheduled onto the target architecture. For each task τi its deadline dli , its number of clock cycles to be executed NCi , and the switched capacitance Ce f fi are given. Each processor can vary its supply voltage Vdd and body bias voltage Vbs within certain continuous ranges ( ...
BD9536FV
BD9536FV

... This pin supplies voltage used for driving the high-side FET. Maximum absolute ratings are 23V from GND and 5.5V from SW. BOOT voltage swings between VIN + 5VReg and 5VReg during active operation. ・HG1 (26 pin) / HG2 (17 pin) This pin supplies voltage used for driving the gate of the high-side FET. ...
MAX5098A Dual, 2.2MHz, Automotive Buck or Boost Converter with 80V Load-Dump Protection
MAX5098A Dual, 2.2MHz, Automotive Buck or Boost Converter with 80V Load-Dump Protection

... The MAX5098A is a dual-output, high-switching-frequency DC-DC converter with integrated n-channel switches that can be used either in high-side or low-side configuration. Each output can be configured either as a buck converter or a boost converter. In the buck configuration, this device delivers up ...
< 1 ... 29 30 31 32 33 34 35 36 37 ... 367 >

Spark-gap transmitter



A spark-gap transmitter is a device that generates radio frequency electromagnetic waves using a spark gap.Spark gap transmitters were the first devices to demonstrate practical radio transmission, and were the standard technology for the first three decades of radio (1887–1916). Later, more efficient transmitters were developed based on rotary machines like the high-speed Alexanderson alternators and the static Poulsen Arc generators.Most operators, however, still preferred spark transmitters because of their uncomplicated design and because the carrier stopped when the telegraph key was released, which let the operator ""listen through"" for a reply. With other types of transmitter, the carrier could not be controlled so easily, and they required elaborate measures to modulate the carrier and to prevent transmitter leakage from de-sensitizing the receiver. After WWI, greatly improved transmitters based on vacuum tubes became available, which overcame these problems, and by the late 1920s the only spark transmitters still in regular operation were ""legacy"" installations on naval vessels. Even when vacuum tube based transmitters had been installed, many vessels retained their crude but reliable spark transmitters as an emergency backup. However, by 1940, the technology was no longer used for communication. Use of the spark-gap transmitter led to many radio operators being nicknamed ""Sparks"" long after they ceased using spark transmitters. Even today, the German verb funken, literally, ""to spark,"" also means ""to send a radio message or signal.""
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report