• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Z1000U Matrix Configured (NEMA 1)
Z1000U Matrix Configured (NEMA 1)

Starting Time Calculation for Induction Motor
Starting Time Calculation for Induction Motor

design and real time implementation of control algorithm for
design and real time implementation of control algorithm for

... brushes on the rotor and the commutation is performed electronically at certain rotor positions. The stator magnetic circuit is usually made from magnetic steel sheets. The magnetization of the permanent magnets and their displacement on the rotor are chosen, such that the back emf shape is trapezoi ...
Tariff Rule No. 2 Character of Servic
Tariff Rule No. 2 Character of Servic

... Where neon, fluorescent or high intensity discharge lamps, welding transformers, x-ray machines and other devices including air conditioners having power factor below 85%, or non-utility self-generators with induction generators that are served by the Company, the customer shall provide at his/her o ...
2006 Q9 - Loreto Balbriggan
2006 Q9 - Loreto Balbriggan

... Explain why the resistance of the bulb is different when it is not connected to the mains. ____________________________________________________ ...
Current can produce magnetism.
Current can produce magnetism.

Comms Revision Questions
Comms Revision Questions

... Y11 REVISION Communications (PD5) 1) Explain how the train below is able to float and move using magnetism ...
5th Harmonic resonance
5th Harmonic resonance

Lab #7
Lab #7

... – The multimeter is used to measure the RMS (root mean square) voltage (or effective DC voltage because it supplies as much power as a DC voltage source would.) – The DMM can also measure the frequency of the source. ...
working of schrage motor
working of schrage motor

...  Same obtained changing the phase angle of the injected voltage into the secondary winding.  In this case one set of brushes is advanced more rapidly than the other set.  Now the two center lines do not coincide, have an angle ‘ρ’ between them. (“ρ” – Brush shift angle) Fig (d) : Brush set is mov ...
FUNDAMENTALS OF WATER
FUNDAMENTALS OF WATER

... generated using a combination of physical motion and magnetism simplest form of AC generator is constructed using a single loop of wire placed between the poles of a permanent magnet and then rotating it by some suitable mechanical means. magnetic lines of force are interrupted with the rotation of ...
Effective Estimation of Induction Motor Field Efficiency Based on On-site Measurements
Effective Estimation of Induction Motor Field Efficiency Based on On-site Measurements

Professional Affiliations
Professional Affiliations

... Specify test plans and procedures to qualify passive, active and EMI filters used in power electronic applications. Developed a/c dynamometer based torque validation tool for qualifying next generation motor control platforms. Reproduced product errors using simulation software such as Altium Summer ...
Electric Motor
Electric Motor

Instruction and Assembly Manual for Filastruder Written by Tim
Instruction and Assembly Manual for Filastruder Written by Tim

... On the board pictured above, there are two adjustments – labeled CV (left) and CC (right). Since the labels are at the very top of the board, it is difficult to see in the photo – but they’re there. The adjustment knob on the left (CV) controls output voltage, while the adjustment knob on the right ...
How to Select a motor? (Part 1) - Types of motors
How to Select a motor? (Part 1) - Types of motors

... These motors are called Stepper Motor or Step Motor. Behavior of Step Motor recalls the behavior of AC motors. Step motor is built of magnetizes rotor and a stator with number of poles with coils wound around each pole. The step motor motion is characterized by steps, hence not continues motion. Eac ...
2. Specifications
2. Specifications

... lower speeds is desired. This configuration is also referred to as full copper. In full coil mode, the motors should be run at only 70% of their rated current to prevent over heating. ...
Voltage Current Dividers Impedance
Voltage Current Dividers Impedance

... The voltage associated with one impedance Zn in a chain of multiple impedances in series is: ...
Press Applications: eddy-current vs VFDs
Press Applications: eddy-current vs VFDs

... mittent overload capacity, the mechanical unit would be sized to: 65/2.50 = 26 hp, plus 10 percent to account for friction and gear losses, or 26 x 1.1 = 28.6 (round up to 30 hp). A VFD and/or DC drive typically can provide only 150-percent overload, so drive size would be: 65/1.50 = 43.33 hp (abou ...
Current can produce magnetism.
Current can produce magnetism.

i семестр -
i семестр -

Engineering Letters
Engineering Letters

... synchronous machines. Output equation clearly indicates that the size of the machine for the same output can be reduced by choosing higher value of specific electric loading, which amounts to decreased cost of the machine. Moreover, the leakage reactance and the armature reactance of synchronous mac ...
25471_energy_conversion_22
25471_energy_conversion_22

closed-form solution of a three-phase voltage
closed-form solution of a three-phase voltage

... Fig. 6 shows a comparison between the rms values of the currents of the motor and of the static R-L load, when fed from three-phase voltage-source inverters, for different values of phase angles. From this figure it is evident the two sets of results are in very close agreement. ...
A3901 Dual Full Bridge Low Voltage Motor Driver
A3901 Dual Full Bridge Low Voltage Motor Driver

... The A3901 is designed for portable applications with a power-off (Sleep mode) current of 50 nA typical, and an operating voltage of 2.5 to 5.5 V. The A3901 logic inputs are 3 to 5 V logic compatible. Output current can be regulated by pulse width modulating (PWM) the inputs. The full-bridge outputs ...
< 1 ... 403 404 405 406 407 408 409 410 411 ... 489 >

Stepper motor



A stepper motor or step motor or stepping motor is a brushless DC electric motor that divides a full rotation into a number of equal steps. The motor's position can then be commanded to move and hold at one of these steps without any feedback sensor (an open-loop controller), as long as the motor is carefully sized to the application in respect to torque and speed.Switched reluctance motors are very large stepping motors with a reduced pole count, and generally are closed-loop commutated.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report