![Mounting Instruction](http://s1.studyres.com/store/data/007899845_1-ef06419b96038cd32f0237d54d86de6c-300x300.png)
Mounting Instruction
... The company STÖBER ANTRIEBSTECHNIK GmbH + Co. KG accepts no liability for damages resulting from non-adherence to the instructions or the particular regulations. ...
... The company STÖBER ANTRIEBSTECHNIK GmbH + Co. KG accepts no liability for damages resulting from non-adherence to the instructions or the particular regulations. ...
Single-Ended Signal Conditioning Circuit for
... similar to that of variant a, in that the negative section of the DC-bus can be taken as the common reference potential. However, the disadvantage is the increased stray inductance. In high dynamic drives and high-power applications, current is usually measured in the output phases of the inverter ( ...
... similar to that of variant a, in that the negative section of the DC-bus can be taken as the common reference potential. However, the disadvantage is the increased stray inductance. In high dynamic drives and high-power applications, current is usually measured in the output phases of the inverter ( ...
6-semester, sgp ex 603{viva question with answer}
... 1. After the first ground fault, assuming it remains as a single fault, the circuit may continue in operation, permitting continued production until a convenient shut down for maintenance can be scheduled. Disadvantages: 1. The interaction between the faulted system and its distributed capacitance m ...
... 1. After the first ground fault, assuming it remains as a single fault, the circuit may continue in operation, permitting continued production until a convenient shut down for maintenance can be scheduled. Disadvantages: 1. The interaction between the faulted system and its distributed capacitance m ...
Untitled
... The ElectriCalc Pro can be used to determine motor Full-Load Current (Amps) based on entries for Motor Horsepower (HPmotor), Phase and Voltage. You can also find an equivalent Motor Horsepower if you have entered Voltage and Full-Load Current values. Only HP Motor and Voltage entries as defined by N ...
... The ElectriCalc Pro can be used to determine motor Full-Load Current (Amps) based on entries for Motor Horsepower (HPmotor), Phase and Voltage. You can also find an equivalent Motor Horsepower if you have entered Voltage and Full-Load Current values. Only HP Motor and Voltage entries as defined by N ...
Service Manual
... SG SPARE PARTS LIST - 230V (7.5 - 40 HP) Description CONTROL PCB assembly POWER PCB assembly SMPS (CTRL) PCB assembly SMPS (DRV) PCB assembly DM+CT PCB assembly SNUBBER PCB assembly ...
... SG SPARE PARTS LIST - 230V (7.5 - 40 HP) Description CONTROL PCB assembly POWER PCB assembly SMPS (CTRL) PCB assembly SMPS (DRV) PCB assembly DM+CT PCB assembly SNUBBER PCB assembly ...
Ultra3000 Digital Servo Drives Installation Manual
... levels used for shunting and DC bus overvoltage limits are adjusted to be compatible with the voltage limit of the motor. ...
... levels used for shunting and DC bus overvoltage limits are adjusted to be compatible with the voltage limit of the motor. ...
IOM - Enviro-Tec
... 1. With all electrical devices, there is a danger of shock. Lethal voltages are present at the supply connection of all power transformers. Use caution when measuring operating voltages with these units. 2. At the beginning of each section are “Common Problems.” To save time, check these items first ...
... 1. With all electrical devices, there is a danger of shock. Lethal voltages are present at the supply connection of all power transformers. Use caution when measuring operating voltages with these units. 2. At the beginning of each section are “Common Problems.” To save time, check these items first ...
INVERTER FR-D700 SC INSTALLATION GUIDELINE FR-D720S-008SC to 100SC-EC
... 앫 Before starting wiring or inspection, check to make sure that the operation panel indicator is OFF, wait for at least 10 minutes after the power supply has been switched off, and check that there are no residual voltage using a tester or the like. The capacitor is charged with high voltage for som ...
... 앫 Before starting wiring or inspection, check to make sure that the operation panel indicator is OFF, wait for at least 10 minutes after the power supply has been switched off, and check that there are no residual voltage using a tester or the like. The capacitor is charged with high voltage for som ...
CURRENT MIRROR CIRCUIT WITH ACCURATE MIRROR GAIN
... transistor pair. The split factor is dependent on the desired mirror gain and the nominal β value. ...
... transistor pair. The split factor is dependent on the desired mirror gain and the nominal β value. ...
Touch and Step Potential Calculations
... The effective resistance of a person's feet (with respect to earth) when standing on a surface layer is not the same as the surface layer resistance because the layer is not thick enough to have uniform resistivity in all directions. A surface layer derating factor needs to be applied in order to co ...
... The effective resistance of a person's feet (with respect to earth) when standing on a surface layer is not the same as the surface layer resistance because the layer is not thick enough to have uniform resistivity in all directions. A surface layer derating factor needs to be applied in order to co ...
LTC3108 - Ultralow Voltage Step-Up Converter
... The LTC3108 utilizes a MOSFET switch to form a resonant step-up oscillator using an external step-up transformer and a small coupling capacitor. This allows it to boost input voltages as low as 20mV high enough to provide multiple regulated output voltages for powering other circuits. The frequency ...
... The LTC3108 utilizes a MOSFET switch to form a resonant step-up oscillator using an external step-up transformer and a small coupling capacitor. This allows it to boost input voltages as low as 20mV high enough to provide multiple regulated output voltages for powering other circuits. The frequency ...
Stepper motor
![](https://commons.wikimedia.org/wiki/Special:FilePath/StepperMotor.gif?width=300)
A stepper motor or step motor or stepping motor is a brushless DC electric motor that divides a full rotation into a number of equal steps. The motor's position can then be commanded to move and hold at one of these steps without any feedback sensor (an open-loop controller), as long as the motor is carefully sized to the application in respect to torque and speed.Switched reluctance motors are very large stepping motors with a reduced pole count, and generally are closed-loop commutated.