Bulletin CW-E Clamp-on Power Meters CW120,CW121,CW240
... Product of Yokogawa Meters & Instruments Corporation ...
... Product of Yokogawa Meters & Instruments Corporation ...
Stand-Alone Switch-Mode Lithium-Ion Battery-Charger Controller General Description Features
... with only a ±0.8% total voltage error at the battery terminals. The external N-channel switch and synchronous rectifier provide high efficiency over a wide input voltage range. A built-in safety timer automatically terminates charging once the adjustable time limit has been reached. The MAX1737 regu ...
... with only a ±0.8% total voltage error at the battery terminals. The external N-channel switch and synchronous rectifier provide high efficiency over a wide input voltage range. A built-in safety timer automatically terminates charging once the adjustable time limit has been reached. The MAX1737 regu ...
AN-566: A Geophone/Hydrophone Acquisition Reference Design
... Input Filtering Some filtering of the input signal coming from the sensor is usually required before acquisition. Depending on the application, the requirements of this filter can vary among EMI/RFI filtering to prevent high frequency noise coming in and being detected by the acquisition system, com ...
... Input Filtering Some filtering of the input signal coming from the sensor is usually required before acquisition. Depending on the application, the requirements of this filter can vary among EMI/RFI filtering to prevent high frequency noise coming in and being detected by the acquisition system, com ...
Caddock - Type MK Precision Power Film Radial
... leads do not require additional bending prior to insertion, and the standard lead spacing can reduce the time required for assembly. ...
... leads do not require additional bending prior to insertion, and the standard lead spacing can reduce the time required for assembly. ...
Inductor FAQ`s - RCD Components
... FAQ – “What impact does frequency have on the measured inductance value?” Inductance increases as the frequency approaches the SRF (self-resonant frequency) level. Therefore the inductance level measured at low frequency is typically lower than that at higher frequencies. Along the same lines, the m ...
... FAQ – “What impact does frequency have on the measured inductance value?” Inductance increases as the frequency approaches the SRF (self-resonant frequency) level. Therefore the inductance level measured at low frequency is typically lower than that at higher frequencies. Along the same lines, the m ...
1.8V 0.18µm CMOS Novel Successive Approximation ADC With
... We see in the pseudo code that if the input “y” is equal to the search value “x” then we fall through all the code and iterate to the next fetch of data. If the data is only out one position either up or down, it only takes one cycle, as we only operate in one loop for an additional clock cycle. Tho ...
... We see in the pseudo code that if the input “y” is equal to the search value “x” then we fall through all the code and iterate to the next fetch of data. If the data is only out one position either up or down, it only takes one cycle, as we only operate in one loop for an additional clock cycle. Tho ...
Developing Reliable Isolation Circuits - Low
... Isolation circuits designed to withstand the rigors of industrial environments are the focus of this white paper. Industrial electronic equipment commonly uses galvanic isolators to protect systems and users from potentially hazardous voltages. It is well known that industrial equipment must operate ...
... Isolation circuits designed to withstand the rigors of industrial environments are the focus of this white paper. Industrial electronic equipment commonly uses galvanic isolators to protect systems and users from potentially hazardous voltages. It is well known that industrial equipment must operate ...
Mode VI (t6-t7): The output capacitor C supplies the load
... Zeta converter [11]-[17]. However, the result is a topology with many power elements. Since PBBC has two switches, providing soft-switching conditions for both switches needs more elements. E.g., in a ZCT PBBC, if by employing only one auxiliary cell soft-switching conditions can be provided for bot ...
... Zeta converter [11]-[17]. However, the result is a topology with many power elements. Since PBBC has two switches, providing soft-switching conditions for both switches needs more elements. E.g., in a ZCT PBBC, if by employing only one auxiliary cell soft-switching conditions can be provided for bot ...
ZXLD1322
... Control is achieved by sensing the LED current in a series resistor (RM), connected between the two inputs of the LED Current Monitor. This generates a proportional current (IMON) that charges the external integrator capacitor CFB. IMON is balanced against a reference discharge current (IADJ) genera ...
... Control is achieved by sensing the LED current in a series resistor (RM), connected between the two inputs of the LED Current Monitor. This generates a proportional current (IMON) that charges the external integrator capacitor CFB. IMON is balanced against a reference discharge current (IADJ) genera ...
Super Mini DIPIPM Ver.6 Series
... compensate the characteristics of the short-circuit protection function embedded in the LVIC. As a result, the variance in the detected voltage for short-circuit protection has been reduced from the conventional ±10% to ±5%. This improved accuracy allows 10% expansion of the inverter overload operat ...
... compensate the characteristics of the short-circuit protection function embedded in the LVIC. As a result, the variance in the detected voltage for short-circuit protection has been reduced from the conventional ±10% to ±5%. This improved accuracy allows 10% expansion of the inverter overload operat ...
AP3436/A Description Pin Assignments
... modulation (PWM) mode with 1.25MHz switching frequency internally, which allows small-sized components, such as capacitors and inductors. This feature greatly simplifies the design of switchmode power supplies. Under PWM mode, the device remains at the fixed PWM operation (typical at 1.25MHz), regar ...
... modulation (PWM) mode with 1.25MHz switching frequency internally, which allows small-sized components, such as capacitors and inductors. This feature greatly simplifies the design of switchmode power supplies. Under PWM mode, the device remains at the fixed PWM operation (typical at 1.25MHz), regar ...
Lab 2 - Rose
... Data points must be shown. A smooth curve must join the points reasonably well. Do not force the curve to pass through points that are clearly “bad.” ...
... Data points must be shown. A smooth curve must join the points reasonably well. Do not force the curve to pass through points that are clearly “bad.” ...
Schneider Telemechanique Altivar 71 Installation Manual (0.37kW
... • If the drive is not turned on for a long period, the performance of its electrolytic capacitors will be reduced. • If it is stopped for a prolonged period, turn the drive on every two years for at least 5 hours to restore the performance of the capacitors, then check its operation. It is recommend ...
... • If the drive is not turned on for a long period, the performance of its electrolytic capacitors will be reduced. • If it is stopped for a prolonged period, turn the drive on every two years for at least 5 hours to restore the performance of the capacitors, then check its operation. It is recommend ...
Designing Non-Invert Buck-Boost (Zeta) Cnvrts
... Figure 1. COT regulators do not require loop compensation and provide excellent transient performance with minimum design effort. Nonsynchronous operation results in reduced switching frequency at a very light load which delivers higher efficiency than a comparable fixed frequency converter. In many ...
... Figure 1. COT regulators do not require loop compensation and provide excellent transient performance with minimum design effort. Nonsynchronous operation results in reduced switching frequency at a very light load which delivers higher efficiency than a comparable fixed frequency converter. In many ...
Eaton 9390 UPS Brochure
... and load. However, in the real world, the UPS must be able to accept power from and deliver power to circuits that have a wide range of power factors. Older or worn equipment often results in lower power factor readings. Some new servers operate at unity power factor. Lightly loaded facilities such ...
... and load. However, in the real world, the UPS must be able to accept power from and deliver power to circuits that have a wide range of power factors. Older or worn equipment often results in lower power factor readings. Some new servers operate at unity power factor. Lightly loaded facilities such ...
Comparative Analysis of Series and Parallel Photovoltaic Arrays
... Photovoltaic (PV) systems have been the fastest growing energy technology over the last decade. This technology is been disseminated in residential applications employing underutilized spaces on rooftops [1]. Many different topologies of PV systems have been developed for residential applications, s ...
... Photovoltaic (PV) systems have been the fastest growing energy technology over the last decade. This technology is been disseminated in residential applications employing underutilized spaces on rooftops [1]. Many different topologies of PV systems have been developed for residential applications, s ...
MAX15091/MAX15091A Evaluate: MAX15091/MAX15091A Evaluation Kits General Description
... Note: Indicate that you are using the MAX15091 when contacting these component suppliers. ...
... Note: Indicate that you are using the MAX15091 when contacting these component suppliers. ...
NUREG/CR-4570 SAND86-0299 RP DESCRIPTION AND TESTING OF AN ...
... initiated fires has concentrated on passing large currents (typically more than 90 A in #12 AWG wire) through cables to generate sufficient heat within the conductor to cause the surrounding insulation to ignite [2]. Many circuits are protected by overcurrent devices such that currents of 10 to 15 A ...
... initiated fires has concentrated on passing large currents (typically more than 90 A in #12 AWG wire) through cables to generate sufficient heat within the conductor to cause the surrounding insulation to ignite [2]. Many circuits are protected by overcurrent devices such that currents of 10 to 15 A ...
LM19 2.4V, 10A, TO-92 Temperature Sensor (Rev. E)
... Accuracy is defined as the error between the measured and calculated output voltage at the specified conditions of voltage, current, and temperature (expressed in°C). Non-Linearity is defined as the deviation of the calculated output-voltage-versus-temperature curve from the best-fit straight line, ...
... Accuracy is defined as the error between the measured and calculated output voltage at the specified conditions of voltage, current, and temperature (expressed in°C). Non-Linearity is defined as the deviation of the calculated output-voltage-versus-temperature curve from the best-fit straight line, ...
Evaluates: MAX1572 MAX1572 Evaluation Kit General Description Features
... pad labeled OUT. Connect the ground terminal of the voltmeter to the pad labeled GND nearest the OUT pad. Connect a load from OUT to the GND pad closest to OUT. 3) Preset the power supply to between 2.6V and 5.5V, and turn the power supply off. 4) Connect the positive power-supply terminal to the pa ...
... pad labeled OUT. Connect the ground terminal of the voltmeter to the pad labeled GND nearest the OUT pad. Connect a load from OUT to the GND pad closest to OUT. 3) Preset the power supply to between 2.6V and 5.5V, and turn the power supply off. 4) Connect the positive power-supply terminal to the pa ...
Mains electricity
Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.