wassenaar-arrangement-control-list-of-dual-use-goods-and
... including 6.8 GHz with a "fractional bandwidth" greater than 15%, and having any of the following: 1. A peak saturated power output greater than 500 W (57 dBm) at any frequency exceeding 2.7 GHz up to and including 2.9 GHz; 2. A peak saturated power output greater than 270 W (54.3 dBm) at any freque ...
... including 6.8 GHz with a "fractional bandwidth" greater than 15%, and having any of the following: 1. A peak saturated power output greater than 500 W (57 dBm) at any frequency exceeding 2.7 GHz up to and including 2.9 GHz; 2. A peak saturated power output greater than 270 W (54.3 dBm) at any freque ...
instruction manual cs-7b
... output to be obtained from the test set. BRUSHES #1, #2, and #3 are provided to control the magnitude of the outputs; and the EXT. VOLTMETER Switch is used in conjunction with the TO EXT. V.M. binding posts to measure the outputs with an external voltmeter, and to determine which potential is applie ...
... output to be obtained from the test set. BRUSHES #1, #2, and #3 are provided to control the magnitude of the outputs; and the EXT. VOLTMETER Switch is used in conjunction with the TO EXT. V.M. binding posts to measure the outputs with an external voltmeter, and to determine which potential is applie ...
Measuring Instruments and Testers
... primarily to measure electrical quantities. To measure means to compare a known quantity with an unknown quantity. The standards of measure of the PTB in Brunswick (German Federal Institute of Physics and Metrology) are used as comparative quantities for our multimeters This is confirmed by means of ...
... primarily to measure electrical quantities. To measure means to compare a known quantity with an unknown quantity. The standards of measure of the PTB in Brunswick (German Federal Institute of Physics and Metrology) are used as comparative quantities for our multimeters This is confirmed by means of ...
TD-1 Manual - Millennia Media
... broadcasts, microphones, mixing consoles, or any associated equipment, downtime costs, loss of goodwill, or claims of any party dealing with purchaser for such damages resulting from the use of this product. All warranties, express and implied, including the warranties of merchantability and fitness ...
... broadcasts, microphones, mixing consoles, or any associated equipment, downtime costs, loss of goodwill, or claims of any party dealing with purchaser for such damages resulting from the use of this product. All warranties, express and implied, including the warranties of merchantability and fitness ...
The Complete Battery Reconditioning Report
... Pictures courtesy of Isidor Buchmann's "Batteries in a Portable World" ...
... Pictures courtesy of Isidor Buchmann's "Batteries in a Portable World" ...
NX3DV2567 1. General description Low-ohmic four-pole double-throw analog switch
... 1. General description The NX3DV2567 is a four-pole double-throw analog switch (4PDT) optimized for switching WLAN-SIM supply, data and control signals. It has one digital select input (S) and four switches each with two independent input/outputs (nY0 and nY1) and a common input/output (nZ). Schmitt ...
... 1. General description The NX3DV2567 is a four-pole double-throw analog switch (4PDT) optimized for switching WLAN-SIM supply, data and control signals. It has one digital select input (S) and four switches each with two independent input/outputs (nY0 and nY1) and a common input/output (nZ). Schmitt ...
WATTS BAR
... The Tennessee Valley Authority (TVA) is a corporation of the United States Government serving the State of Tennessee and parts of six other States in the southeast on the boundaries of Tennessee. TVA is interconnected with electric power companies to the north, west, south, and east of its service a ...
... The Tennessee Valley Authority (TVA) is a corporation of the United States Government serving the State of Tennessee and parts of six other States in the southeast on the boundaries of Tennessee. TVA is interconnected with electric power companies to the north, west, south, and east of its service a ...
ENG- FM FM1 FM2 Keeping Ovens Operating Manual
... It must be used and read by the operators, maintenance employees and by the staff and purchaser for what it concerns spare parts. It must be located with care in a known place, protected by dirty and humidity and it must be always available for consultation by the operators. Read it and give to read ...
... It must be used and read by the operators, maintenance employees and by the staff and purchaser for what it concerns spare parts. It must be located with care in a known place, protected by dirty and humidity and it must be always available for consultation by the operators. Read it and give to read ...
MAX9320/MAX9320A 1:2 Differential LVPECL/LVECL/HSTL Clock and Data Drivers General Description
... The MAX9320/MAX9320A are low-skew, 1-to-2 differential drivers designed for clock and data distribution. The input is reproduced at two differential outputs. The differential input can be adapted to accept single-ended inputs by applying an external reference voltage. The MAX9320/MAX9320A feature ul ...
... The MAX9320/MAX9320A are low-skew, 1-to-2 differential drivers designed for clock and data distribution. The input is reproduced at two differential outputs. The differential input can be adapted to accept single-ended inputs by applying an external reference voltage. The MAX9320/MAX9320A feature ul ...
Manual (Units installed prior to Nov 2006)
... 6.2 Equipment Description.......................................................................................................1 ...
... 6.2 Equipment Description.......................................................................................................1 ...
US-APWR Chapter 8 Electric Power D
... There are two non-Class 1E 13.8 kV medium voltage (MV) buses N1 and N2, four non-Class 1E 6.9 kV MV buses N3, N4, N5 and N6, two non-Class 1E 6.9 kV MV permanent buses P1 and P2, and four Class 1E 6.9 kV MV buses A, B, C and D. All low voltage buses are provided power from the MV buses. Each of the ...
... There are two non-Class 1E 13.8 kV medium voltage (MV) buses N1 and N2, four non-Class 1E 6.9 kV MV buses N3, N4, N5 and N6, two non-Class 1E 6.9 kV MV permanent buses P1 and P2, and four Class 1E 6.9 kV MV buses A, B, C and D. All low voltage buses are provided power from the MV buses. Each of the ...
MAX9310 1:5 Clock Driver with Selectable LVPECL Inputs and LVDS Outputs General Description
... with selectable LVPECL/HSTL inputs and LVDS outputs, designed for clock distribution applications. This device features an ultra-low propagation delay of 345ps with 45.5mA of supply current. The MAX9310 operates from a 2.375V to 2.625V power supply for use in 2.5V systems. A 2:1 input multiplexer is ...
... with selectable LVPECL/HSTL inputs and LVDS outputs, designed for clock distribution applications. This device features an ultra-low propagation delay of 345ps with 45.5mA of supply current. The MAX9310 operates from a 2.375V to 2.625V power supply for use in 2.5V systems. A 2:1 input multiplexer is ...
UT64CAN333x CAN FD Transceivers
... transceivers operate on a single +3.3 V power supply and receive data with an input common-mode in the range of -7 V to +12 V. The CANH and CANL outputs are fault protected against short-circuits by over-current shutdown circuitry. Each UT64CAN333x CAN transceiver is capable of: ...
... transceivers operate on a single +3.3 V power supply and receive data with an input common-mode in the range of -7 V to +12 V. The CANH and CANL outputs are fault protected against short-circuits by over-current shutdown circuitry. Each UT64CAN333x CAN transceiver is capable of: ...
BDTIC
... Figure 1 was developed to support customers during their first steps designing applications with TM EconoPACK 4 3-level NPC2 modules. This evaluation board was designed in addition to the module ...
... Figure 1 was developed to support customers during their first steps designing applications with TM EconoPACK 4 3-level NPC2 modules. This evaluation board was designed in addition to the module ...
national transmission
... tubes in the boiler. The boiler will be shut down, and the tubes allowed cooling and draining. Thus we have in effect eliminated two hazards. They are: The heat, and The pressurized water in the tubes Now other hazards may still remain but we eliminated those that were practical to eliminate. Ok ...
... tubes in the boiler. The boiler will be shut down, and the tubes allowed cooling and draining. Thus we have in effect eliminated two hazards. They are: The heat, and The pressurized water in the tubes Now other hazards may still remain but we eliminated those that were practical to eliminate. Ok ...
Mini-Gel Electrophoresis Unit for DNA, RNA and Protein
... • The i-Mupid should always be operated with caution. Careless handling may result in electrical shock. Never operate damaged or leaking equipment. • Always turn off and remove the power supply before removing the cover. • Certain reagents mentioned in this manual are of a hazardous nature (e.g. eth ...
... • The i-Mupid should always be operated with caution. Careless handling may result in electrical shock. Never operate damaged or leaking equipment. • Always turn off and remove the power supply before removing the cover. • Certain reagents mentioned in this manual are of a hazardous nature (e.g. eth ...
A Low-Voltage MOS Cascode Current Mirror for All Current Levels
... bias circuit that generates a Vcn appropriate for a unit-width transistor with a channel current of about Ic. • The degree to which the bottom transistor is saturated depends on m and Ic/Ib —the larger these values, the closer V is to VDSsat . • Vcn is about a diode drop plus a saturation voltage. ...
... bias circuit that generates a Vcn appropriate for a unit-width transistor with a channel current of about Ic. • The degree to which the bottom transistor is saturated depends on m and Ic/Ib —the larger these values, the closer V is to VDSsat . • Vcn is about a diode drop plus a saturation voltage. ...
Mains electricity
Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.