• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Double Tail Comparator Using FinFET
Double Tail Comparator Using FinFET

... submicron design technologies. The selection of particular topology is dependent upon the requirements and applications of the design. Low power circuit design has emerged as a principal theme in today’s electronics industry . This Comparators have essential influence on the overall performance in h ...
Will-Burt - Blackwood Fire Company
Will-Burt - Blackwood Fire Company

... The rescuers must make sure that in case wires have been found, the power company has actually disconnected that section of their circuit. Downed wires should always be treated as if they were voltage-carrying. Only the power companies have qualified personnel to ground out circuits and to assure th ...
BV500 PCB Kit BV500T BV500T PCB for the BV500 IC
BV500 PCB Kit BV500T BV500T PCB for the BV500 IC

... 4. Serial Interface The serial connection is designed for a type 3 USB to serial device that simply plugs into the right angled female socket. The pins are correct. The 5V output is used to power the device not the 3v3 output as this PCB has a built in voltage regulator. Any other USB to serial devi ...
62-0388 Class 1000 Meter Installation Manual
62-0388 Class 1000 Meter Installation Manual

... To ensure a safe installation, the Class 1000 meter requires an external switch mechanism, such as a circuit breaker, be installed on the Class 1000 MAINS input wiring. The switch mechanism must be installed in close proximity to the meter and easily reachable for the operator. This device must also ...
3- 0 CHAPTER 3 • Cell Design and Theory • Lead
3- 0 CHAPTER 3 • Cell Design and Theory • Lead

... in an 8-hour period. The charger is set for the constant potential of 2.39 volts per cell (the gassing voltage) and the starting current is limited to 16-20 amperes per 100 Ah of the rated 6-hour ampere-hour capacity. This initial current is maintained constant until the average cell voltage in the ...
Motor - Schneider Electric
Motor - Schneider Electric

... the highest starting torque is supplied by the Full Voltage Motor starter the higher the voltage, the higher the starting torque with a full voltage motor starter the network capability to accept the inrush current needs to be verified the inrush current may generate a voltage drop at the terminals ...
MN201003EN/ Old S201-10-1
MN201003EN/ Old S201-10-1

... technicians in the installation, operation and service of Eaton's Cooper Power™ series single-phase overhead distribution transformers. Overhead distribution transformers are designed for installation on single-phase above ground systems. All units are constructed for weather exposed mounting on a u ...
LTC2376-20 20-Bit, 250ksps, Low Power SAR
LTC2376-20 20-Bit, 250ksps, Low Power SAR

... Note 1: Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. Exposure to any Absolute Maximum Rating condition for extended periods may effect device reliability and lifetime. Note 2: All voltage values are with respect to ground. Note 3: When these p ...
BD95835EFJ
BD95835EFJ

... 4.5V to 18V, 3A 1ch Synchronous Buck Converter BD95835EFJ ●Description BD95835EFJ is a 1ch synchronous buck converter that can generate a wide range of output voltage at the input voltage range (4.5V to 18V). Space-saving and high efficient switching regulator can be achieved due to built-in N-MOSFE ...
EMIF01-10005
EMIF01-10005

... VCL = VBR + Rd.IPP This protection function is splitted in 2 stages. As shown in figure A3, the ESD strikes are clamped by the first stage S1 and then its remaining overvoltage is applied to the second stage through the resistor R. Such a configuration makes the output voltage very low at the Vout l ...
Operating Instructions
Operating Instructions

... Subject to change without notice ...
- Orion Car Audio
- Orion Car Audio

Fast Switching Direct Torque Control Using a Single DC-link
Fast Switching Direct Torque Control Using a Single DC-link

... new active voltage complex space vectors (CSVs) are synthesized by the conventional active voltage space vectors (SVs). The corresponding sectors are rotated in the anticlockwise direction by 30 degrees. A selection table is defined to select the CSVs. Based on the “Different Phase Mode”, the output ...
AD7414
AD7414

PX-13 - ADI Global Distribution
PX-13 - ADI Global Distribution

... Rugged Piezoelectric Switches Rosslare's PX-13 are general purpose high performance 22mm panel-mounted Normally Open (N.O) Piezoelectric switches suited for long-life and rugged use applications. Made from AL6061 Aluminum alloy material with Type II anodization, the units are available in 7 colors. ...
Photovoltaic Railroad Power Installations
Photovoltaic Railroad Power Installations

... must run on time and critical wayside applications must work—safety is paramount. Inoperable gates, signals and communication systems simply are not an option. The industry demands a PV power system that provides high output, is reliable, has high system autonomy and is operationally cost-effective. ...
Celectra 1-3 charger 811 - E
Celectra 1-3 charger 811 - E

... battery is charging. Note: Do not adjust the charge rate switch in this state. Note: This charger is designed to automatically detect cell count selection errors as an added safety feature. If the wrong cell switch selection is chosen for a 1-, 2-, or 3-cell pack and the start button is pushed the b ...
BD2200GUL, BD2201GUL
BD2200GUL, BD2201GUL

... Our Products are designed and manufactured for use under standard conditions and not under any special or extraordinary environments or conditions, as exemplified below. Accordingly, ROHM shall not be in any way responsible or liable for any damages, expenses or losses arising from the use of any RO ...
Design procedures for small synchronous generators with interior
Design procedures for small synchronous generators with interior

... a permanent magnet machine. But the requirements on the design are always the same. These include general a cost effective design with an optimized magnet volume, simple controllability and a high efficiency factor. Especially in connection with small generators the controllability, the transient be ...
Power Supplies
Power Supplies

TSOP582.., TSOP584..
TSOP582.., TSOP584..

... typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in ...
BRT11 - Vishay
BRT11 - Vishay

... typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in ...
product catalogue - amelec Electronic GmbH
product catalogue - amelec Electronic GmbH

... already installed (transformers, cables) • Reduce line voltage drop (that could cause problems in motors starting or plants served by long MV power lines with low short circuit power). • Reduce energy losses due to Joule effect in transformers and cables The payback of a power factor correction syste ...
Keysight 1GC1-4266 DC-12 GHz Packaged Divide-by
Keysight 1GC1-4266 DC-12 GHz Packaged Divide-by

... input is “slew–rate” limited, requiring fast rising and falling edge speeds to properly divide. The device will operate at frequencies down to DC when driven with a square–wave. Due to the presence of an off–chip RF–bypass capacitor inside the package (connected to the VCC contact on the device), an ...
API9221EV1 User Guide Issue 3
API9221EV1 User Guide Issue 3

... charge and discharge cycle can be quickly and simply demonstrated without a battery. The circuit includes a load consisting of an electrolytic double layer capacitor bank of 5 Farads to facilitate this demonstration. The assembly also includes a set of resistive loads. There is a logic enable input, ...
< 1 ... 558 559 560 561 562 563 564 565 566 ... 1974 >

Mains electricity



Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report